Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
056 A101 3 Plex - Floor Plan - Level 2 & 3
DN DN UP UP DN UP DN DN DN ONE-HOUR DWELLING SEPARATION (FIRE PARTITION), ONE-HOUR-FIRE-RESISTANT CONSTRUCTION SEPARATION LEGEND ONE-HOUR FIRE PARTITION, ONE-HOUR-FIRE- RESISTANT CONSTRUCTION ONE-HOUR-FIRE-RATED CONSTRUCTION A201 B2 A201 D2 A202B3 A202 D3 D1 A301 B3 A301 D4 A301 D1 A352 1 1 4 4 AA B B A451 C1 A452 C1 23'-2"23'-2"24'-2" 4 5/8" 10'-3 3/8" 12'-0" 6" 7 1/2"10 1/2" 9'-2" 12'-0" 6" 7 1/2"10 1/2" 9'-2" 13'-6" 6"33'-6"4" 1'-8" 4 5/8" 23'-8 1/2"9'-4 7/8" 5'-8" 4" 23'-2"23'-2"24'-2" 6" 13'-10" 8'-10" 6" 4 1/16" 1'-2" 12'-3" 8'-11" 6" 4" 1'-2" 12'-3 3/8" 10'-0" 4 5/8"33'-6"1'-8" 9'-2"23'-11 3/8" 4 5/8" 5'-8" 4" G G G BBB A AAA A A F C D DC A H R3 R5 R4 R7 R7 R3 R3 R5 R4 R7 R7 R3 R3 R5 R4 R7 R7 R3 LIVING DINING KITCHEN MECH. PNTRY. CLST.CLOSET BATH BEDRM. 1 LIVING DINING KITCHEN MECH. PNTRY. CLST.CLOSET BATH BEDRM. 1 LIVING DINING KITCHEN MECH. PNTRY. CLST.CLOSET BATH BEDRM. 1 D6 A352 A502 D5 UNIT 1 UNIT 2 UNIT 3 71'-6" 6'-8" 7'-2" 3'-6" 2'-7" 2'-9"6'-2" 6'-1" 3'-6" 2'-7" 2'-10"6'-1 1/2" 6'-1 7/8" 3'-6" 2'-7" 3'-11" C D 41'-6"15'-6 1/2" 6'-0" 2'-2" 5'-3 3/8" 5'-0" 6'-0" 6'-0"4'-2" 5'-0" 6'-0" 6'-0"4'-2" 5'-0" 7'-0" 6'-6"5'-8"6'-0"5'-8"6'-0"A 1'-8" 4 5/8"2'-0" 4 5/8"1'-8"2'-0"C E C A E E D D D D E E C C A C E E G G G G F F G G F F F F G G F F C E C 2 2 3 315'-1"5'-0"3'-10 3/8"2'-8"6'-6"A452 C1 D4 A353 A. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THE ARCHITECT. B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES. C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS. PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS. D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: • MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), • FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL (ADJUST FOR TILE WHERE SHOWN). E. CONCRETE FOUNDATION WALLS RETAINING EARTH TO RECEIVE TWO COATS OF BITUMINOUS DAMP PROOFING MATERIAL. F. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS TO BE INSTALLED THROUGHOUT THE ENTIRE BUILDING PER NFPA 13R. G. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION H. SEE INTERIOR ELEVATIONS ON AI201 AND MILLWORK DETAILS ON AI551 FOR FINISHES OF MILLWORK BASES, AND COUNTERTOPS SEE SHEETS A151, A152 FOR REFLECTED CEILING PLAN INFORMATION. I. SEE SHEETS AI101, AI102, FOR FINISH INFORMATION. CONFIRM FINISHES WITH OWNER PRIOR TO ORDERING. J. SEE A601, A602, AND A603 FOR DOOR AND WINDOW INFORMATION. K. GENERAL CONTRACTOR SHALL REVIEW AND APPROVE ALL APPLIANCES WITH OWNER PRIOR TO PURCHASING EQUIPMENT AND FABRICATING MILLWORK. L. SEE THE SPECIFICATION FOR ADDITIONAL INFORMATION. M. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHER ARCHITECTURAL GENERAL INFORMATION. N. SEE G003 FOR WALL TYPES. O. PROVIDE BACKING/BLOCKING FOR WALL MOUNTED ITEMS-INCLUDING GRAB BARS, HANDRAILS, SIGNAGE AND EQUIPMENT AS REQUIRED. P. TILE IS TO BE SET OVER CEMENTITIOUS BACKER BOARD UNDERLAYMENT. RECESS SLAB AS/IF REQUIRED. VERIFY WITH OWNER. Q. DO NOT SCALE DRAWINGS. GENERAL NOTES A201 B2 A201 D2 A202B3 A202 D3 D1 A301 B3 A301 D4 A301 D1 A352 1 1 4 4 AA B B A451 D1 A452 D1 23'-2"23'-2"24'-2" 4 5/8" 10'-3 3/8" 12'-0" 6" 1'-6" 9'-2" 12'-0" 6" 1'-6" 9'-2" 13'-6" 6"33'-6"4"5'-8"9'-5"23'-8 3/8"4 5/8"1'-8"4"23'-2"23'-2"24'-2" 6" 13'-10" 8'-10" 6" 4 1/16" 1'-2" 12'-3" 8'-11" 6" 4" 1'-2" 12'-3 3/8" 10'-0" 4 5/8" 6"33'-6"4"5'-8"4 5/8"23'-11 3/8"9'-2"1'-8"4"B B B BBB A A F E F F E F H A R3 R5R3 R3R5 R3R5R3 R5 R3 R3 R5R3 R3R5 R3R5R3 R5 R3 R3 R5R3 R3R5 R3R5R3 R5 R3 BEDRM. 4 CLOSET BATH CLOSET BEDRM. 3 BEDRM. 2 CLOSET BATH LNDRY. BATH BEDRM. 4 CLOSET BATH CLOSET BEDRM. 3 BEDRM. 2 CLOSET BATH LNDRY. BATH BEDRM. 4 CLOSET BATH CLOSET BEDRM. 3 BEDRM. 2 CLOSET BATH LNDRY. BATH D6 A352 UNIT 1 UNIT 2 UNIT 3 71'-6" 6'-8" 7'-2" 3'-6" 2'-7" 2'-9"6'-2" 6'-1" 3'-6" 2'-7" 2'-10"6'-1 1/2" 6'-1 7/8" 3'-6" 2'-7" 3'-11" E F A 41'-6"9'-4 3/8" 14'-4" 6'-9" 2'-8" 5'-3 3/8" 5'-0" 6'-0" 6'-0"4'-2" 5'-0" 6'-0" 6'-0"4'-2" 5'-0" 7'-0" 6'-6"4 5/8"5'-8"4 5/8"6'-0"5'-8"6'-0"1'-8" 4 5/8"4 5/8"2'-0"1'-8"14'-1"5'-0"4'-10 3/8"2'-8"6'-6"C EC A E D D D D E C C C C E E E GG G G H F F G G F F F F G G F F C C E J J CE 2 2 3 3 06.21 06.21 06.21 A452 D1 D4 A353 F 233 SOUTH PLEASANT GROVE BLVD. SUITE #105 PLEASANT GROVE, UTAH 84062 PHONE: (801) 769-3000 core@corearch.com NOT FOR CONSTRUCTION THE INFORMATION HEREIN IS THE PROPERTY OF CORE ARCHITECTURE AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2023 CORE ARCHITECTURE, LLC PROFESSIONAL STAMP SHEET NUMBER SHEET TITLE A 1 REVISIONS DATE: PROJECT #: PM / PA: PIC: PROJECT INFORMATION DESCRIPTION DATE THIS DRAWING SET IS INTENDED TO BE PRINTED IN COLOR CONSULTANT INFORMATION DRAWING SET STATUS B C D 2 3 4 5 6 PROJECT TITLE AND ADDRESS8/3/2023 12:51:14 PMAutodesk Docs://23-029 Bozeman Multifamily/23-029 Bozeman Multifamily Row House_3 Plex.rvtFLOOR PLAN - LEVEL 2 & 3 A101 28 JULY 2023 23-029 MRR MMA PERMIT REVIEW AND BID PACKAGETHE BOÖTES - 3 PLEXOPPORTUNITY WAY AND SOUTH11TH AVEBOZEMAN, MONTANA 59718KEYNOTES 06.21 PULL-DOWN ROOF ACCESS WITH LADDER. SCALE: 3/16" = 1'-0"A101 FLOOR PLAN - LEVEL 2B2 SCALE: 3/16" = 1'-0"A101 FLOOR PLAN - LEVEL 3D2