HomeMy WebLinkAbout040 A301 Building D - Building SectionsGENERAL NOTES A. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS, AND ASSEMBLIES PRIOR TO CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THE ARCHITECT. B. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS TO BE INSTALLED THROUGHOUT THE ENTIRE BUILDING PER NFPA 13R. C. CONCRETE FOUNDATION WALLS RETAINING EARTH TO RECEIVE TWO COATS OF BITUMINOUS DAMP PROOFING MATERIAL. D. MINIMUM ROOF CLASSIFICATION TO BE CLASS 'C'. E. MINIMUM ROOF SLOPE TO BE 1/4" PER FOOT. F. INSULATE ENTIRE FLAT ROOF AREAS WITH R-49 POLYISOCYANURATE ABOVE ROOF DECKING. G. EXPOSED FOUNDATION WALLS TO RECEIVE RUBBED FINISH. H. SEE ENGINEERING SHEETS FOR ADDITIONAL INFORMATION. I. MASONRY TO HAVE CONTROL JOINTS AT 30'-0" O.C. MAXIMUM. J. NOT ALL INTERIOR ELEMENTS ARE NOTED FOR CLARITY. SEE WALL SECTIONS, DETAILS, AND WALL TYPES FOR ADDITIONAL INFORMATION. ONE-HALF-HOUR CORRIDOR (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) ONE-HALF-HOUR DWELLING SEPARATION (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) SEPARATION LEGEND 100'-0" LEVEL 1 FLOOR 111'-2 3/4" LEVEL 2 FLOOR 132'-5 3/4" TOP OF ROOF 96'-0" T.O. FOOTING D 121'-2 7/8" TRUSS BEARING B B2 A302 B2 A302 A351 D3 A C MASTER BEDROOM 1BEDROOM 1 MASTER BEDROOM 2 CLOSET MASTER BEDROOMBEDROOMCLOSET A351 D6 A351 D5 MASTER BEDROOMBEDROOMCLOSET MASTER BEDROOM 1 MASTER BEDROOM 2 CLOSET BEDROOM 1 09.06 09.0609.06 09.06 09.06 09.06 09.06 09.06 04.26 06.23 06.23 03.05 06.04 06.04 100'-0" LEVEL 1 FLOOR 111'-2 3/4" LEVEL 2 FLOOR 132'-5 3/4" TOP OF ROOF 96'-0" T.O. FOOTING D 121'-2 7/8" TRUSS BEARING B B2 A302A C A451 D4 A451 D1 A502 B4 01.01 01.01 03.05 06.0706.03 06.23 06.27 06.27 06.27 06.27 233 SOUTH PLEASANT GROVE BLVD. SUITE #105 PLEASANT GROVE, UTAH 84062 PHONE: (801) 769-3000 core@corearch.com NOT FOR CONSTRUCTION THE INFORMATION HEREIN IS THE PROPERTY OF CORE ARCHITECTURE AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2023 CORE ARCHITECTURE, LLC PROFESSIONAL STAMP SHEET NUMBER SHEET TITLE A 1 REVISIONS DATE: PROJECT #: PM / PA: PIC: PROJECT INFORMATION DESCRIPTION DATE THIS DRAWING SET IS INTENDED TO BE PRINTED IN COLOR CONSULTANT INFORMATION DRAWING SET STATUS B C D 2 3 4 5 6 PROJECT TITLE AND ADDRESS8/3/2023 12:43:39 PMAutodesk Docs://23-029 Bozeman Multifamily/23-029 Bozeman Multifamily Building D.rvtBUILDING SECTIONS A301 28 JULY 2023 23-029 MRR MMA PERMIT REVIEW & BID DOCUMENTSTHE BOÖTES -BUILDING DOPPORTUNITY WAY AND SOUTH11TH AVEBOZEMAN, MONTANA 59718KEYNOTES 01.01 ADA COMPLIANT SEMI RECESSED FIRE EXTINGUISHER CABINET WITH 2A10BC FIRE EXTINGUISHER INSIDE. SEE DETAIL D1/A701. 03.05 CONCRETE SLAB OVER 4" OVER 10 MIL VAPOR RETARDER OVER FREE DRAINING GRAVEL. SEE STRUCTURAL FOR SLAB THICKNESS AND REINFORCING. 04.26 ATTIC TO BE INSULATED THROUGHOUT WITH R-38 BLOWN-IN INSULATION. PROVIDE BAFFLES AT EAVE LINE AS REQUIRED. 06.03 SINGLE-PLY ROOF MEMBRANE OVER ROOF 1" POLYISOCYANURATE OVER ONE LAYER ATLAS FR-10 SLIP SHEET OVER STRUCTURAL WOOD SHEATHING. MINIMUM ROOF CLASSIFICATION TO BE AS NOTED ON THE CODE ANALYSIS. INSTALL PER MANUFACTURER'S REQUIREMENTS FOR MECHANICALLY FASTENED SYSTEM. FULLY ADHERE TO VERTICAL SURFACES AND CONTINUOUS BENEATH METAL PARAPET CAP AND DOWN FRONT SIDE 1" MIN. SINGLE-PLY TPO ROOFING. WHITE, 60 MIL. 15 YEAR WARRANTY MATERIALS. 06.04 SHADED AREA INDICATES BUILT-UP POLYISOCYANURATE. CRICKET ROOF TO DRAIN AS REQUIRED. MINIMUM SLOPE 1/4" PER FOOT. 06.07 ROOF ACCESS HATCH AND LADDER. SEE DETAIL B1/A701. 06.23 ARCHITECTURAL ASPHALT SHINGLES OVER 30# FELT WITH ICE AND WATER SHIELD OVER PLYWOOD ROOF SHEATHING. SEE STRUCTURAL. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 06.27 CEILING SYSTEM. SEE REFLECTED CEILING PLANS 09.06 WOOD BEAM OR HEADER. SEE FRAMING PLANS. SCALE: 3/16" = 1'-0"A301 BUILDING SECTION 1B2 SCALE: 3/16" = 1'-0"A301 BUILDING SECTION 2D2