HomeMy WebLinkAbout016 Stormwater Retention CalculationThe Boötes Allison Sub PH 4A - Lots 1 & 2 Block 1 Stormwater Retention Pond Calculations Design Rainfall Freq. 10 year IDF coefficient a 0.64 IDF coefficient b IDF coefficient n 0.65 Pre-Site Development Conditions Contributing drainage area Square feet Acres C Impervious 158,122 3.63 0.50 Total area 158,122 3.63 Composite C 0.50 Retention Pond Calculations Q = CIA C = 0.50 (post-development) I = 0.41 in/hr (10-yr, 2-hr storm) A = 3.63 acres Qpost = 0.74 cfs Retention Storage Provided with Subdivision(ft3) =5,330 ft3 (10-yr, 2-hr storm) Post-Site Development Conditions Contributing drainage area Square feet Acres C Impervious 122,314 2.81 0.90 Landscaped 35,808 0.82 0.20 Total area 158,122 3.63 Composite C 0.74 Retention Pond Calculations Q = CIA C = 0.74 (post-development) I = 0.41 in/hr (10-yr, 2-hr storm) A = 3.63 acres Qpost = 1.10 cfs Retention Storage Requried (ft3) =7,945 ft3 (10-yr, 2-hr storm) Additonal On-Site Retention Storage Required (ft3) =2,616 ft3 (10-yr, 2-hr storm) User Inputs Chamber Model: SC-740 Outlet Control Structure: No Project Name: The Bootes Engineer: Chris Budeski Project Location: Montana Measurement Type: Imperial Required Storage Volume: 2616 cubic ft. Stone Porosity: 40% Stone Foundation Depth: 6 in. Stone Above Chambers: 6 in. Average Cover Over Chambers: 18 in. Design Constraint Dimensions:(30 ft. x 50 ft.) Results System Volume and Bed Size Installed Storage Volume: 2176.24 cubic ft. Storage Volume Per Chamber: 45.90 cubic ft. Number Of Chambers Required: 25 Number Of End Caps Required: 10 Chamber Rows: 5 Maximum Length:43.11 ft. Maximum Width: 25.25 ft. Approx. Bed Size Required: 1062.67 square ft. System Components Amount Of Stone Required: 96 cubic yards Volume Of Excavation (Not Including Fill): 138 cubic yards Total Non-woven Geotextile Required:348 square yards Woven Geotextile Required (excluding Isolator Row): 24 square yards Woven Geotextile Required (Isolator Row): 25 square yards Total Woven Geotextile Required:49 square yards Impervious Liner Required:0 square yards