HomeMy WebLinkAbout029.5 L6.0 IRRIGATION WATER USAGENORNORN89°22'14"E 122.92'N00°43'04"W 160.50'S00°35'44"E 140.00'N00°35'29"W 140.00'N89°22'14"E 119.91'UPUPBFCPCWIRRIGATIONTYPEIRRIGATION WATER USETOTAL AREA /QTYANNUALET RATETOTAL ANNUALH2OH.E. TREEBUBBLER/DRIP6 TREES99 GAL /WEEK1,782 GALH.E. SHRUBBUBBLER/DRIP27 SHRUBS203 GAL /WEEK3,645 GALH.E. PERENNIALDRIP IRRIG.114PERENNIALS228 GAL /WEEK4,104 GALTOTAL ANNUAL H2O REQUIRED: 9,531 GALTOTAL ACRE FEET PER YEAR: .03 ACRE FT SYM DESCRIPTIONIRRIGATION SLEEVE, SCH 40 PVCBFCPIRRIGATION LEGENDCONNECTION POINT AND BACK FLOW TO BEIN FIRE RISER ROOM. LANDSCAPECONTRACTOR TO VERIFY NECESSARYEQUIPMENT PRIOR TO INSTALLATION.IRRIGATION CONTROLLERCWEATHER STATIONWIRRIGATION NOTES AND SPECIFICATIONS1.ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER.2.INSTALL MSMT NOZZLES WHERE POSSIBLE TO CONSERVE WATER3.IRRIGATION MAIN LINE TO BE 1.5" SCH 40 PVC PIPE OR 150 PSI POLY PIPE.4.ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERS. BUBBLERS TO BE EVENLYDISTRIBUTED AROUND BASE OF TREE WITH FOUR (4) EVENLY SPACED BUBBLER EMITTERS.5.TREES AND SHRUBS PLACED WITHIN PLANTING BEDS MAY UTILIZE DRIP IRRIGATION. DRIPIRRIGATION TO BE ADJUSTED PER REQUIREMENTS OF EACH INDIVIDUAL PLANT.6.ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATED WITH DEDICATED DRIP TUBING.DRIP EMITTERS TO BE ADJUSTED PER REQUIREMENTS OF EACH INDIVIDUAL PLANT.RECOMMENDED EMITTERS PER PLANT TYPE:PERENNIALS- (1) 0.5 GPH EMITTERSHRUBS- (2) 1.0 GPH EMITTERS/0.25-1.0 GPM BUBBLERSTREES- (4) 1.0 GPH EMITTERS/0.25-1.0 GPM BUBBLERS***TREES UTILIZING DRIP IN PLANTING BEDS MAY NEED ADDITIONAL EMITTERS TO MEETWEEKLY WATERING REQUIREMENTS.7.ALL HEADS MUST ACHIEVE HEAD-TO-HEAD COVERAGE FOR SOD AREAS.8.SYSTEM SHALL UTILIZE WEATHER / MOISTURE MONITOR.9.BACKFLOW ASSEMBLY AND BLOWOUT ASSEMBLY SHALL BE LOCATED IN MECHANICAL ROOM ORAPPROVED EXTERNAL GRADEBOX. IT IS THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TOCOORDINATE INSTALLATION PER LOCAL CODES AND ORDINANCES AS WELL AS WITH ARCHITECTURE AND ALL OTHER TRADES.10.POWER SOURCE FOR IRRIGATION CONTROLLER TO BE COORDINATED WITH ELECTRICAL ENGINEER,ELECTRICAL CONTRACTOR AND LANDSCAPE CONTRACTOR.11.DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUS OBSTRUCTIONS OR GRADE CHANGES AREPRESENT.12.ALL INFORMATION TO BE FIELD-VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION.13.THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT 'AS-BUILT' IRRIGATION PLAN ON SITEAT ALL TIMES.14.SYSTEM DESIGNED TO FALL WITHIN OPERATING PRESSURE OF 50 PSI AND 12 GPM. IF NOT WITHINLIMITS, CONTRACTOR MUST CONTACT LANDSCAPE ARCHITECT.105020N1L6.01"=20'-0"Irrigation Water UsageIrrigationWater UsageL6.0SHEET NUMBERPROJECT CODEPROJECT ADDRESSARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS.DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ONDRAWING SHEET AND MAY NOT BE REPRODUCED OR USEDFOR OTHER PURPOSES WITHOUT WRITTEN PERMISSIONFROM ARCHITECT.111 N Tracy AveBOZEMAN, MT 59715SHEET NAMEPROJECT NAMEDRAWING REVISIONSDRAWING ISSUE DATEDRAWING ISSUED FORPHONE: (406) 587-4873FOR PLANNINGREVIEW ONLYBIM 360://SBM - Scully Building Main Street/SBM - CENTRAL.rvt8/28/2023 3:34:21 PM SBM112 EAST MAINSTREET -MIXED USEBUILDING112 EAST MAINSTREET BOZEMAN,MT. 59715SP/CCOA -RC #012023-11-01MEP TO PROVIDE 1.5" STUB ANDBACKFLOW PREVENTER FORIRRIGATION.WALL MOUNTED CONTROLLER VERIFYLOCATION IN FIELD, ELECTRICAL AND ARCH. TO PROVIDE &COORDINATE POWER OUTLETWEATHER STATIONVERIFY LOCATIONIN FIELDMEP WILL PROVIDE IRRIGATIONCONNECTION IN LOWER LEVELFIRE RISER ROOM. WATER LINEFOR IRRIGATION WILLCONNECT TO SOUTH END OFBUILDING1RC #11