HomeMy WebLinkAbout020 - Sand & Oil Separator Cut Sheet ANE) E: RSC) N
PRECAST & SUPPLY INC.
11.50' @ TOP
11,25' @ BOTTOM
4" DWV FOR VENT
APPROVED
GASKET
CONTRACTOR TO PROVIDE
ALL INTERIOR PLUMBING EQ.
APPROVED APPROVED
GASKET o' i GASKET
5,83' @ T❑P 0.42'
5.58' @ - - -
B❑TT❑M - � - 0,42'
18"0 - 30"0
❑PENINGS EQ.
APPROVED
GASKET
1" C❑NSEAL PLAN VIEW
AT J❑INTS
(TYPJ
1,00' O 3" AIR GAP, 1.25'
--� C❑NTINU❑US
-
_ (2) 6" DWV
C❑UPLINGS,
OR AS REQ,
5.67'
4.67' 4.42'
INLET OUTLET
SECTION VIEW
1500 GALLON SAND/❑IL SEPERAT❑R HS20-44 TRAFFIC RATED 1 OF 3
Z w m
Q o 7/19 < NTS MAP Q
0 2016 CDo cn Qa
in w
cn Er
�cn
z Uw
Z SAND/OIL SEPERATOR w Z
Q 1500 GALLON / > cnw
o HS20-44 TRAFFIC RATED
TRT -150005❑
A�rNIDERSON
1500 GAL HS20-44 TRAFFIC RATED TANK NOTES:
• CONCRETE IS 5000 PSI @ 28 DAYS.
• CEMENT IS TYPE V(SULFATE RESISTANT).
• REINFORCEMENT:AS PER ENGINEER REQ.
• TANK WEIGHT IS APPROXIMATELY 17,000 LBS.
• TANK HEIGHT FROM BOTTOM TANK TO TOP OF SLAB IS 5.67'.
• APPROVED GASKETS ON INLETS AND OUTLET.
• INLET HEIGHT FROM BOTTOM OF TANK TO INVERT IS 4.67'.
• OUTLET HEIGHT FROM BOTTOM OF TANK TO INVERT IS 4.42'
• (3)ACCESS OPENINGS.
• TOP AND BOTTOM PLACED WITH 1"MASTIC AT JOINT.
• THIS TANK MUST BE PLACED ON COMPACTED 3/4"ROAD-BASE OR SIMULAR MATERIAL.
• MINIMUM RELATIVE COMPACTION IS 95%.
• DO NOT USE FLOWABLE BACKFILL MATERIALS SUCH AS 3/4"WASHED GRAVELS.
• TANK MUST BE BACKFILLED TO TOP BEFORE WATERTESTING.
• ALL LIFTING EYES IN EACH SECTION MUST BE USED.
• MINIMUM BURY DEPTH V-0". MAXIMUM BURY DEPTH 6-0".
• PLUMBING PER ENGINEER AND SUPPLIED AND INSTALLED BY CONTRACTOR.
AVAILABLE UPON REQUEST:
• REINFORCEMENT CERTS.
• CEMENT CERTS.
• AGGRIGATES CERTS.
• ADMIXTURES CERTS.
• CONCRETE TESTING
• MIX DESIGN
BUILT TO:
• ASTM C-890-13
• ASTM C-1613-10
ANDERSON PRECAST & SUPPLY, INC. - SAND/OIL SEPERATOR HS20-44 2 OF 3
TRT -15000S❑
(3) ADDITI❑NAL 18'0 - 30'0
#4 REBAR @ ❑PENING
3' O.C. EA. SIDE
OF ❑PENING
TOP VIEW
11.50' @ TOP
11.25' @ BOTTOM
4' DWV FOR VENT
#4 H❑RIZ. EQ.
@ 7' ❑.C.
(TYP.)
II I
5.83' @ T❑P �'_ �__ 0.42'
5.58' @ _ - C
BOTTOM
0,4T2'
#4 VERTS. ��--
@ 14' O.C.
(TYP.)
EQ,
PLAN VIEW 1,50' WEIRI ~I LAP (TYP.)
WALL LAP
(TYP.)
1 79' 4 45' - 3.47' - 1.79'
I
0.42'
COVERLREBAR
® CONTINUOUS U❑US 0'O,W
r--r T,❑,W,
ANSVERSE �__�- r -- (TYP.)
@ 5' O.C.
ERTS. __ (2) 6' D W V
❑.C. #4 LONGITUDINALCUUPLINGS,
REBAR @ 7' O.C. OR AS REQ5,25' ❑RIZ, #4 TRANSVERSE REBAR ALL WALLREIN.❑.C. @ 18' O.C. E.W., CENTERED IN WALL) CENTERED IN WALL -T
- 0,42' 2.00' LAP
ITUDINAL #4 TRANSVERSE B.D.W. (TYP,)
12' O.C. REBAR @ 7' O.C. (T Y P,)
0 42'
f
SECTI❑N VIEW 1,50' WEIRI
WALL LAP BASE REIN. CENTERED
(TYP.) IN BASE THICKNESS
ANDERSON PRECAST & SUPPLY, INC. - SAND/OIL SEPERATOR HS20-44 3 of 3
TRT -1tM6S❑