Loading...
HomeMy WebLinkAbout069 Electrical Plan-6WV EXISTING TRAIN TRACKS 2 E2.1 H1 -16 GARAGE DOOR MOTOR GEN 1 750 kVA UTILITY XFMR 120V/208Y SECONDARY REF CIVIL FOR EXACT LOCATION. 10' - 0" GENERAL ELECTRICAL NOTES: A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. 3rd FLOOR IS IDENTICAL TO 2nd FLOOR, POWER, LIGHTING, DATA, AND FIRE ALARM, DEVICE AND FIXTURE LAYOUT AND CIRCUITING IS TO BE COPIED FROM 2nd FLOOR TO 3rd. D. 5th FLOOR IS IDENTICAL TO 4th FLOOR, POWER, LIGHTING, DATA, AND FIRE ALARM, DEVICE AND FIXTURE LAYOUT AND CIRCUITING IS TO BE COPIED FROM 4th FLOOR TO 5th. E. PROVIDE ARC-FAULT PROTECTION AS REQUIRE IN NEC 210.12 F. RECEPTACLES INSTALLED UNDER A SINK OR BEHIND A WASHING MACHINE, AND NOT EASILY REACHABLE FOR RESETTING, SHALL BE PROTECTED BY GFCI BREAKERS. G. COORDINATE KITCHEN ISLAND RECEPTACLE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH IN. ENSURE INSTALLATION LOCATION COMPLIES WITH NEC 210.52.C.3.LEVEL 1 100' - 0" LEVEL 1 100'-0"WP/GFI 2000A MCB, 120/208Y 3⌀, 4WIRE 20 GANG METER BASE NEAREST EDGE OF ELECTRIC METERS SHALL BE WITHIN 10' OF THE GAS METERS, BUT NOT CLOSER THAN 3-1/2' BIM FILE PATH: SHEET NO.: TITLE: COPYRIGHT 2021 SMA, P.C. REVISIONS: KEYMAP: ARCHITECT SEAL: PROJECT: PROJECT LOCATION: PREPARED FOR: LOGO: CONSULTANT: PROJECT NUMBER: DRAWN BY: CHECKED BY: TEAM: PHASE: DATE: PROJECT NUMBER:Plot Date:NOT FOR CONSTRUCTION HELENA P: 406-442-4933 BOZEMAN P: 406-219-2216 www.sma.design C:\Users\JBrianG\Documents\BG MILL MEP CENTRAL v22_bgoveia@energy-1.net.rvt 8/4/2022 4:53:14 PME2.1 22-024 2022-06-03 ELECTRICAL POWER 1st FLOOR Author Checker BG MILL CONDOMINIUMS 22-024 714 EAST MENDENHALL SREET BOZEMAN, MT 59715 50% SCHEMATIC DESIGN No.Date Revision Description E2.1 SCALE: 1/8" = 1'-0" 1 - MAIN FLOOR PLAN - POWER 1 KEYED NOTES : 1. PROVIDE EV CHARGING INFASTRUCTURE FOR FUTURE CHARGING STATION INSTALLATION. PROVIDE 1-1/4" CONDUIT FROM PANEL "EV" TO THIS GENERAL LOCATION WITH PULL STRING. COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH IN. 2. PROVIDE 1" CONDUIT WITH PULL STRING FROM PANEL H1 FOR FUTURE CAR LIFT THIS GENERAL LOCATION. COORDINATE LOCATION WITH OWNER, AND WHICH LOCATIONS WILL BE RECEIVING LIFTS IMEDIATELY. PROVIDE BREAKER, FEEDER, AND TERMIANTION AT LIFT FOR THOSE LOCATIONS. COORDINATE CONNECTION OF HARD WIRED OR RECEPTACLE WITH VENDOR CUT SHEET. 3. 30A/2P/3R NON-FUSED DISCONNECT FOR MECHANICAL UNITS TO BE INSTALLED BY ELECTRICAL CONTRACTOR IF NOT PROVIDED AS INTEGRAL PIECE OF UNIT ITSELF. COORDINATE WITH MECHANICAL CONTRACTOR. ENSURE NEC REQUIRED CLEARANCES ARE MAINTAINED. E2.1 SCALE: 1/4" = 1'-0" SERVICE2