Loading...
HomeMy WebLinkAbout045 Arch Floor Plan-61 1 2 2A A B B SD-A3.01 SD-A3.02 SD-A3.00 SD-A3.02 4 4 5 5 6 6 7 7 8 8 9 9 10 10 C C D D E E F F 3 3 2A 2A EXIT LOBBY STAIR 1 1/2" / 12" 1/2" / 12" 1/2" / 12" SPR-A3.00 1 SPR-A3.021 SPR-A3.01 1 SPR-A3.022 1 2 3 4 5 6 7 8 9 10 11 12 13 ELEVATOR MAINT. CL. STAIR 2 ROOF TOP DECK & LOUNGE ROOF TOP DECK & LOUNGE 11 11 1 1 2 SPR-A2.06 2 2 2 3 3 4 4 4 5 5 5 5 6 6 12 13 13 13 1. SEE SHEET A1.00 FOR ROOF ASSEMBLIES. 2. ROOF DRAINS AND OVERFLOW DRAINS, WHEN NOT DIMENSIONED, ARE TO BE CENTERED OR EQUALLY SPACED WITHIN THE ROOF AREA AS SHOWN. DIMENSIONS INDICATED FOR ROOF DRAINS AND OVERFLOW DRAINS ARE APPROXIMATE AND MAY BE ADJUSTED +/-1'-0" AS REQUIRED. 3. CENTER OF ROOF DRAINS TO BE LOCATED 2'-0" MINIMUM FROM ADJACENT ROOF EDGE, PARAPET OR WALLS AS SHOWN UNLESS NOTED OTHERWISE. 4. IN ADDITION TO MECHANICAL AND ELECTRICAL ITEMS SHOWN ON THIS DRAWING, SEE MECHANICAL AND ELECTRICAL DRAWINGS TO VERIFY LOCATIONS, TYPES, SIZES AND QUANTITIES OF MECHANICAL AND ELECTRICAL ROOF PENETRATIONS/ITEMS. 5. TAPERED INSULATION SHALL BEGIN AT 0" THICKNESS AT TOP EDGE OF ROOF DRAIN SUMPS AND SLOPE UP AND AWAY AT 1/4" PER FOOT AS SHOWN TO ACCOMPLISH POSITIVE DRAINAGE AT ALL LOCATIONS. 6. MECHANICAL CONTRACTOR TO FURNISH ALL CURBS REQUIRED FOR HVAC EQUIPMENT, SEE MECHANICAL. 7. ALL FLASHING, ROOFING TIE-INS AND ROOFING ACCESSORIES NECESSARY FOR ROOFING PENETRATIONS, CURBS AND MOUNTING ASSEMBLIES SHALL BE PROVIDED BY THE ROOFING CONTRACTOR AND APPROVED BY THE ROOFING MANUFACTURER. SHEET NOTES -ROOF PLAN T.O. ROOF STRUCTURE 170'-0" SPR-A2.06 3 1/4" / 12"1/4" / 12" T.O. ROOF STRUCTURE 170'-0" R-30 CONTINUOUS & TAPERED INSULATION VAPOR BARRIER -BRING UP MIN. 8" TO VERTICAL SURFACE 1/4" GLASS MATT SHEATHING EPDM MEMBRANE -WRAP UP VERTICAL SURFACE MIN. 8" FLAT PROFILE TERM BAR CONTINUOUS W/ SEALANT BED BEHIND -FASTENERS AS REQUIRED CONTINUOUS SELF-ADHERED MEMBRANE OVER EPDM MEMBRANE STEEL STUD SPACED PER STRUCTURAL REQUIREMENTS PREFIN. MTL. PARAPET CAP 3/4" CORE-A-VENT DRAINAGE SPACER 5/8" FIBER CEMENT PANELS LEVEL UNISTRUT ASSEMBLY -VERIFY W/ CONTRACTOR AND MECH. UNIT MFR. FASTEN MECH. UNIT TO THE UNISTRUT - PER MFR. VERIFICATION BIM FILE PATH: SHEET NO.: TITLE: COPYRIGHT 2022 SMA, P.C. REVISIONS: KEYMAP: ARCHITECT SEAL: PROJECT: PROJECT LOCATION: PREPARED FOR: LOGO: CONSULTANT: PROJECT NUMBER: DRAWN BY: CHECKED BY: TEAM: PHASE: DATE: PROJECT NUMBER:Plot Date:SITE PLAN REVIEW HELENA P: 406-442-4933 BOZEMAN P: 406-219-2216 www.sma.design C:\Users\JordanC\Documents\22-024 - BG Mill-R22_jordancL2SGC.rvt 8/11/2022 1:07:31 PMSPR-A2.06 22-024 2022-08-10 FLOOR PLAN -ROOF LEVEL Author Checker BG MILL CONDOMINIUMS 22-024 714 EAST MENDENHALL SREET BOZEMAN, MT 59715 SITE PLAN REVIEW SUBMITTAL N 1/8" = 1'-0"SPR-A2.06 1 SPR - ROOF DECK No.Date Revision Description KEYNOTES - ROOF PLAN 1 PRIMARY AND SECONDARY OVERFLOW RAINS - SEE PLUMBING AND ARCH. DETAILS/DRAWINGS 2 MECHANICAL EQUIPMENT - SEE MECH. DRAWINGS 3 24" X 24" MFR. STANDARD WALKWAY PADS 4 MECHANICAL SCREEN - SEE DETAILS 5 UNIT BALCONY BELOW 6 RAISED PLANTERS AROUND OCCUPYABLE ROOF TOP AREA - SEE LANDSCAPING PLANS 7 HOT TUB @ ROOF DECK AMMENITY SPACE 8 FIRE PIT AT ROOF DECK LOUNGE - SEE MECHANICAL PLANS 9 SEATING @ LOUNGE AREA - PER OWNER 10 BAR SEATING AND BBQ AREA 11 TRELLIS OVERHEAD - SUNSHADING FOR BBQ 12 LANDSCAPE AND ROOF TOP DECK LOUNGE LIGHTING - SEE LANDSCAPING AND ELECTRICAL PLANS 13 SEDUM TRAYS - SEE LANDSCAPING 1/4" = 1'-0"SPR-A2.06 2 TYP. SECTION @ MECHANICAL SCREEN 3/4" = 1'-0"SPR-A2.06 3 TYP. DETAIL @ MECHANICAL SCREEN