HomeMy WebLinkAbout062 - C600 Site and Utility Details3" 8" 8"(MIN) DEPTH SCARIFIED, MOISTURE CONDITIONED, & RECOMPACTED SUBGRADE NOTES: 1.FOR ADDITIONAL SECTION DETAIL SEE ADDENDUM TO THE GEOTECHNICAL INVESTIGATION REPORT JANUARY 18,2023 BY RAWHIDE ENGINEERING AND PRELIMINARY GEOTECHNICAL INVESTIGATION REPORT SOUTH 40 SUBDIVISION REPORT OCTOBER 21, 2022 2.PRIOR TO PLACEMENT OF THE BASE COURSE, THE EXPOSED SUBGRADE SHALL BE SCARIFIED TO A MINIMUM DEPTH OF EIGHT INCHES (8") BELOW EXISTING GRADE, MOISTURE CONDITIONED, AND RECOMPACTED TO 95% (MINIMUM) OF MAXIMUM DENSITY AS DETERMINED BY ASTM D 698. 3.AGGREGATE SUB-BASE COURSE SHALL CONFORM TO SECTION 02234 OF THE MPWSS AND INCORPORATE A MAXIMUM PARTICLE SIZE OF THREE INCHES (3"). 4.AGGREGATE BASE COURSE SHALL CONFORM TO SECTION 02235 OF THE MPWSS AND INCORPORATE A MAXIMUM PARTICLE SIZE OF ONE AND ONE-HALF INCHES (1-1/2"). 5.AGGREGATE BASE COURSE SHALL BE COMPACTED TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D 698. 6.ASPHALT SHALL BE TYPE B OR APPROVED EQUAL WITH PERFORMANCE GRADE 58-28 BINDER IN ACCORDANCE WITH AASHTO MP1 COMPACTED TO A MINIMUM OF 97% OF THE MARSHALL UNIT WEIGHT. 7.THE FINISHED SURFACE MUST BE FREE OF RUTS, DEPRESSIONS, OR OTHER SURFACE DEFECTS EXCEEDING ONE-QUARTER INCH (1/4") AS MEASURED WITH A TEN FOOT (10') STRAIGHT EDGE PARALLELING THE FINISHED SURFACE. MAKE CORRECTIONS BY SCARIFYING AND RELAYING THE MIXTURE AT CONTRACTOR EXPENSE. MINIMUM DEPTH OF 6" MINUS PIT-RUN GRAVEL ASPHALT CONCRETE PAVEMENT NATIVE GROUND MIRAFI 600X SUBGRADE SEPARATION FABRIC OR ENGINEER APPROVED EQUAL 6"MINIMUM DEPTH OF 1-1/2" MINUS CRUSHED BASE COURSE 4"(MIN) CLASS M-4000 CONCRETE 3"(MIN) 3/4" MINUS CRUSHED LEVELING COURSE MATERIAL NOTES: 1.SEE PRELIMINARY GEOTECHNICAL INVESTGATION REPORT SOUTH 40 SUBDIVISION OCTOVER 21, 2022 FOR ADDITIONAL DETAIL. 2.SPACE CONTRACTION JOINTS TO MATCH THE WIDTH OF SIDEWALK. 3.INSTALL EXPANSION JOINT MATERIAL AT EVERY FIFTH JOINT FOR THE FULL DEPTH OF CONCRETE. 4.FINISH CONCRETE WITH LIGHT BROOM FINISH. 2% MAX CROSS SLOPE COMPACTED SUBGRADE4" (MIN) 1'-0"6" (MIN) 6" (MIN) 9" 214" 2'-0" 412" [0.38']512" [0.45] 6" (MIN) 6" (MIN) 4" R 3" R 3/4" PER 1' SLOPE TOPSOIL COMPACTED BACKFILL COMPACTED SUBGRADE COMPACTED CRUSHED BASE COURSE MATERIAL FINISHED ASPHALT SURFACE TO BE 1/8" TO 1/4" ABOVE GUTTER LIP LAYDOWN CURB 4" (MIN) 1'-0"6" (MIN) 6" (MIN) 6" (MIN) 6" (MIN) 4" R 1/2" PER 1' SLOPE 2" 9" 612" [0.53']7" [0.58'] 2'-0" TOPSOIL COMPACTED BACKFILL COMPACTED SUBGRADE COMPACTED CRUSHED BASE COURSE MATERIAL FINISHED ASPHALT SURFACE TO BE FLUSH WITH GUTTER LIP LAYDOWN CURB 3" R NOTES: 1.BASE COURSE AND SUBGRADE SHALL BE COMPACTED TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D 698. 2.CONTRACTION JOINTS SHALL BE PLACED AT TEN FOOT (10') MINIMUM INTERVALS AND SHALL HAVE A MINIMUM DEPTH OF THREE-QUARTER INCH (3/4") AND WIDTH OF ONE-EIGHTH INCH (1/8"). 3.ONE-HALF INCH (1/2") EXPANSION JOINT MATERIAL SHALL BE PLACED AT ALL PC'S, PT'S, CURB RETURNS, AND AT NOT MORE THAN 300' INTERVALS. THE EXPANSION JOINT MATERIAL SHALL EXTEND THROUGH THE FULL DEPTH OF THE CURB AND GUTTER. 4.NO CURB AND GUTTER SHALL BE PLACED WITHOUT A FINAL FORM INSPECTION BY THE OWNER THEIR AUTHORIZED REPRESENTATIVE, AND/OR THE CITY OF BOZEMAN (AS REQUIRED). 5.CONCRETE SHALL BE CLASS M-4000. 6.CONTRACTOR SHALL BACKFILL CURB WITHIN SEVEN (7) DAYS OF PLACEMENT. 0.75'6"MIN4" CONCRETE SLAB W/#4 BARS @ 18" OCEW #4 BARS @ 15" MAX. OCEW (CENTERED) JOINT FILLER CONCRETE WALKWAY PER CIVIL NOTE: 1.ALL STEPS ARE 5' IN WIDTH. 2.CONTRACTOR TO VERIFY RISE AND TREAD DIMENSIONS OF EACH SET OF STEPS BEFORE CONSTRUCTING. JOINT FILLER VARIES SEE PLANS VARIESSEE PLANS4" MIN7" MAX1'-0" (MIN) & 2'-0" (MAX) WATER SERVICE LINE STUB (SEE C.O.B. STANDARD DRAWING NO. 02660-6) PROPERTY LINE OR EASEMENT SERVICE LINE 1'-0" (MIN) & 2'-0" (MAX) 1'-0" (MIN) & 2'-0" (MAX) FOUNDATION WALL BACKFLOW PREVENTION ASSEMBLY (AS REQUIRED) TO DOMESTIC FIXTURES DOWNSTREAM SHUT-OFF** FLOOR METER* ANGLE STOP OR STRAIGHT STOP *METER SHALL BE SAME SIZE AS INCOMING LINE - NO EXCEPTIONS, METER MUST CONNECT DIRECTLY TO ANGLE OR STRAIGHT STOP AND BACKFLOW DEVICE **DOWNSTREAM SHUT-OFF VALVE MUST BE SEPARATE FROM BACKFLOW DEVICE DETAIL A TYPICAL WALL PENETRATION (NOT TO SCALE) 1'-0" (MIN) TO DOMESTIC FIXTURES DOWNSTREAM SHUT-OFF** FOUNDATION WALL METER* ANGLE STOP BACKFLOW PREVENTION ASSEMBLY (AS REQUIRED) QUARTER-BEND COUPLING (1-1/2" & 2" SERVICES ONLY) *METER SHALL BE SAME SIZE AS INCOMING LINE - NO EXCEPTIONS, METER MUST CONNECT DIRECTLY TO ANGLE OR STRAIGHT STOP AND BACKFLOW DEVICE **DOWNSTREAM SHUT-OFF VALVE MUST BE SEPARATE FROM BACKFLOW DEVICE DETAIL B TYPICAL FLOOR PENETRATION (CRAWL SPACE) (NOT TO SCALE) WATER MAIN CURB STOP AND BOX NEAREST FOUNDATION WALL TO CURB STOP SEE DETAILS A & B BELOW6'-6" (78") (MIN) COVER WATER SERVICE LINE INSTALLED BY CUSTOMER (SERVICE APPLICATION & PLUMBING PERMIT REQUIRED) INSTALLATION REQUIREMENTS: 1.WATER SERVICE LINE INSTALLATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF BOZEMAN WATER SUPERINTENDANT. 2.SERVICE LINES SHALL BE TYPE K COPPER FOR 3/4", 1", 1-1/2", AND 2" SERVICES. REFER TO C.O.B. STANDARD DRAWING NO. 02660-12 FOR 4" AND LARGER DOMESTIC SERVICE LINES. SERVICE LINES BETWEEN 2" AND 4" ARE NOT ALLOWED. 3.STRAIGHT COPPER TUBING SHALL BE USED FOR 1-1/2" AND 2" SERVICES. 4.SERVICE LINES SHALL BE BEDDED 3" UNDER AND OVER THE PIPE WITH SAND. NATIVE MATERIAL MAY BE USED AS BEDDING IF IT CONFORMS TO THE REQUIREMENTS OF MONTANA PUBLIC WORKS STANDARD DRAWING 02221-2 AND DOES NOT CONTAIN ANY MATERIAL LARGER THAN 3/4". 5.PROVIDE FLEXIBLE, WATER TIGHT CONNECTION FOR ALL WALL OR FLOOR PIPE PENETRATIONS. 6.METERS SHALL BE INSTALLED BY THE CITY WATER DEPARTMENT AT CUSTOMERS' EXPENSE. 7.NO SERVICE LINE SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE WATER DEPARTMENT. 8.CONTACT CITY OF BOZEMAN WATER DEPARTMENT FOR APPROVED LIST OF COPPER CONNECTIONS. 9.WATER SERVICE LINE MAY BE REDUCED TO A SMALLER SIZE THAN THE WATER SERVICE STUB. REDUCTION MUST BE MADE WITHIN 18" OF CURB STOP. 10.METER, BACKFLOW PROTECTION, AND INCOMING SERVICE LINE MUST ALL BE THE SAME SIZE. VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! 2023COPYRIGHT © MORRISON-MAIERLE, SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\5659\019 - SWX SITE PLANS 1-3\ACAD\SHEETS\002 BLOCK 5 LOT 2 SHEETS\C600 SITE DETAILS.DWGREVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle PLOTTED BY:CELINE SAUCIER ON Aug/01/2023 SRX BLOCK 5 LOT 2 BOZEMAN MONTANA SITE AND UTILITY DETAILS 5659.019 11 C600 CMS CMS JAU 8/1/2023 8/1/2023 R Know what's below. before you dig.CallKnow what's below. before you dig.Call R 1 CURB AND GUTTER DETAILS CITY OF BOZEMAN STANDARD DRAWING NO. 02528-1 STANDARD CATCH CURB & GUTTER STANDARD SPILL CURB & GUTTER 3 CONCRETE SIDEWALK DETAIL NOT TO SCALE 2 STANDARD DUTY BITUMINOUS PAVEMENT DETAIL NOT TO SCALE SCALE: 1" = 1'-0" No. 49499 CELINE M PROFESSIONAL E N G INEERM O N TANA LICENSED SAUCIER 3 STAIR DETAIL NOT TO SCALE NOT TO SCALE WATER SERVICE LINE FROM CURB STOP TO BUILDING - LINES 2" AND SMALLER 02660-15