Loading...
HomeMy WebLinkAbout014 Residential Water Usage & Peaking factorDaily Water Usage Analysis Nexus Point Phase II Average Daily Flow No of Units 142 Residents/unit 1.66 Gallons per Capita/day 170 Average Daily Flow 40,072 gpd Peaking Factor Calculations Zoning Density (residents/unit) Total Popoulation R5 1.66 236 =Q(max)= 18 + P 0.50 P = Population/thousands = 47\3/1000 = 0.236 Q(ave)4 + P 0.50 Peaking Factor = Peak Hour Water Usage Average Daily Usage 40,072 gpd Maximum Hour Usage 120,217 gpd Maximum Hour Usage 5009.1 gph Maximum Hour Usage 83.5 gpm 4.12 Peaking Factor Units/AcreAcres 5.33 26.64