HomeMy WebLinkAbout009 Gran Cielo Block 14 Concept Review Comments Response Narrative
1 | P a g e
895 Technology Boulevard, Suite 203, Bozeman, MT 59718 | 406.586.0262
Gran Cielo – Block 14
Concept Review Comments Narrative
Application 22027
Thank you for your comments regarding Gran Cielo Subdivision Phase II Block 14 Multi
Residential concept application. Please find the following responses to your comments from your
letter dated August 12, 2022.
Madison Engineering comments are in bold below.
Concept Review Comments
1. Need to make sure enclosure is out far enough that if cars are parked in spaces
next to enclosure that doors are still able to open 180 degrees without hitting
parked cars.
Response: Acknowledged. Refer to Architectural sheets for trash enclosure.
2. (1) Need a detailed plan for refuse enclosures. (2) Refuse enclosures will need to be
covered
Response: Details for the refuse enclosure is located on the Architectural sheets.
3. BMC 38.410.070 and DSSP V.A and V.B - Water and Sewer Design Criteria - Prior to a
determination of adequacy the applicant must provide an estimate of the peak-hour sanitary
sewer demand as well as the average and max day demands of domestic water usage for the
proposed site development. The estimates must be certified by a professional engineer. The
applicant must confirm water and sewer demands are within the approved subdivision
reports.
Response: Certified peak-hour sanitary sewer demand is included in submittal.
4. BMC 38.220.080.A (2.g) - The applicant must submit a peak hour trip generation value
to the City to determine whether a traffic impact study is required. The applicant must
confirm traffic generation numbers are within the approved subdivision TIS.
Response: Previous TIS report and TIS report correspondence is included. See
document 010 Gran Cielo TIS Report and document 011 Gran Cielo Block
14 TIS Correspondence.
5. Will need to see proposed transformer and electric service locations. All electric primary
2 | P a g e
needs to be installed within utility easements. Will need to see proposed screening methods
for electric service & transformer.
Response: Northwest Energy has been reached out to regarding their power design.
6. BMC 38.410.060 (C.1) - The applicant must provide a thirty (30) foot public utility
easement to accommodate both water and sewer. An additional ten (10) feet of width is
required for each additional main that occupies the easement.
Response: Draft 30’ public utility easement is included. See document 008 Sewer
Pipeline Access Easement.
7. DSSP Fire Service Line Standard Plans for all fire service lines must be submitted to the
City Engineering Department (engsubmittals@bozeman.net) for review. The applicant must
prepare plans and specifications for any fire service line in accordance with the City’s Fire
Service Line Policy. The plans must be prepared by a Professional Engineer and be
provided to and approved by the City Engineer prior to initiation of construction of the fire
service or fire protection system. The applicant must also provide Professional Engineering
services for construction inspection, post-construction certification and preparation of
mylar record drawings. Fire service plans, and domestic services 4" or larger, must be a
standalone submittal, separate from the site plan submittal. City of Bozeman applications
for service must be completed by the applicant.
Response: Acknowledged.
8. Provide text on cover sheet that states all required parkland was given at subdivision.
Park also recommends keeping an up-to-date parkland tracking table that shows the current
balance of IILP carried over from subdivision and previous phases.
Response: Text is now included on cover sheet. See drawings 001 Cover sheet
9. W/S Sewer service for Southwest building
This private sewer service can't be located through the easement to maintain our water
main.
Response: Per correspondence with Bozeman Engineering and the Fire Marshall, the
utility plan has been updated.
10. W/S Sewer Main
This is a bad choice for the location of a sewer main. We won't allow large trees or
structures in this easement and it looks like that is exactly what you will want to put there
with this segment being under a sidewalk surrounded by open space. This sewer main
should be in a drive aisle along with the water in a common easement. In addition, we have
private segments of water service crossing through the separate sewer easement.
Response: The sewer manhole is located in the blvd because we are trying to utilize
and existing sewer main stub. The tree located near the manhole has been
removed.
11. ENG Water Service Line
BMC 38.410.070.B.2 - The proposed water service line exceeds 150 feet in length. The
3 | P a g e
length of service lines from the main to the structure may not exceed 150 feet in length,
unless approved in writing by the city.
Response: Acknowledged. Utility layout has been adjusted. See drawing 004 C0.3
Utility Plan
12. ENG Proposed Sewer Main
Please show the proposed sewer main on this and all other plans.
Response: The proposed sewer main is shown on all sheets besides the existing
conditions sheet and detail sheets.
13. ENG Proposed water/sewer mains
The option exists to connect service lines directly to the water/sewer mains located around
the subject property. The applicant needs to describe reasoning for proposing new
water/sewer main extensions into the site instead.
Response: Correspondence has taken place with City Engineering and Bozeman Fire
Marshal. Layout has been updated to install services off existing water main
lines. Previously proposed water main has been removed.
14. As proposed fire supports the project. Please ensure that sidewalks are included from
the fire riser room exterior door to public way.
Response: Sidewalks have been included from fire riser room exterior door to public
way.
15. Process – BMC 38.230.020. A site plan is required for the proposed project. A master
site plan is a generalized development plan that establishes building envelopes and overall
entitlements for complex, large-scale projects that will require multiple years to reach
completion. A master site plan application is not required, however if phasing is proposed
to extend beyond 2 years, a Master Site Plan allows that entitlement to be extended to 5
years.
Response: Acknowledged. Master site plan was previously submitted for review.
16. In addition to, or as listed in the submittal checklist, a Site Plan must include: 1. A
detailed phasing plan that includes: a) Detailed construction management plan, b) Project
phasing and associated improvements necessary for the independent function of each phase
such as parking, pedestrian connections to the street, and open space. Without an approved
phasing plan, final occupancy may not be granted until the entire site is built out and ready
for occupancy. 2. If submitting a master site plan, the Phase 1 site plan may be reviewed
concurrently. Subsequent phases require additional site plan application reviews. 3. Provide
a legal framework for shared access between lots to establish access to shared facilities such
as parking and open space. 4. With the formal submittal, provide screening and amenity
details for each shared open space area.
Response: Acknowledged.
17. PLNG Phasing - Transportation Pathways
The east-west and north-south pedestrian sidewalks and associated landscaping, as
4 | P a g e
transportation pathways, must be included with the phase 1 construction.
Response: Acknowledged.
18. PLNG Phasing - Open Space
No common open space is to be provided with phase 1. Each phase must be fully functional
if subsequent phases are not complete prior to occupancy. BMC 38.220.080.A.2.q. Only
50% of required open space may be provided by balconies. Demonstrate with the formal
submittal how 100% of the required open space will be provided with phase 1, it occupancy
is granted prior to the completion of future phases.
Response: Open space areas and calculations have been adjusted. Refer to document
016 Open Space Calculations and drawing 005 C0.4 Open Space
19. PLNG Bicycle Parking
Provide pad and bicycle rack details showing the shared bicycle parking is meeting the
required dimensions. BMC 38.540.050
Response: Acknowledged. Bicycle detail on drawing 011 C2.2 Site Details
20. PLNG Coversheet - Phasing
Provide open space and parking calculations per phase, as well as the total.
Response: Total open space and parking calculations provided with MSP application
and Phase 1 site plan application. Phase 1 shows phased open space and
parking calculations on drawings and documents.
21. PLNG Lighting
Provide a photometric plan with associated light fixture details demonstrating compliance
with 38.570.
Response: Acknowledged.
22. PLNG Landscaping
Landscaping â BMC 38.550. Provide a phased landscaping plan that addresses mandatory
landscaping provisions in Section 38.550.050 including street frontages, open space,
parking lot landscaping requirements, landscaping used for screening of service areas, open
spaces, and parking areas, and internal landscaped areas with the formal submittal.
Response: Acknowledged. See Landscape drawings.
23. PLNG - Block Frontages
Block frontage â BMC 38.510. This project will include multiple block frontages: A.
Special Residential: For residences with ground floor living spaces facing a sidewalk or
pedestrian path within a residential development, the building must feature at least one of
the public/private space transition elements described in Section 38.530.030.J. Identify all
special residential frontages interior to the site, and describe the transition method in the
formal submittal. B. Landscaped Block Frontage: In the formal submittal narrative and
drawings demonstrate compliance with the block frontage required design elements
including but not limited to: Building placement, building entrances, façade transparency
(provide on elevation sheets), weather protection, and parking location.
5 | P a g e
Response: Please see Architects response. Refer to document 017 Site Concept Review
Architectural Response.
24. PLNG - Open Space
On-site residential open space â BMC 38.520.060.B. All multi-household development
must provide minimum usable open space equal to 100 square feet per dwelling unit for
studio and one bedroom dwellings and 150 square feet per dwelling unit for dwellings with
two or more bedrooms. The required open space may be provided in a combination of
ways: shared open space, ground level private outdoor space, balconies, common indoor
recreation areas, and shared roof decks. Provide an exhibit detailing proposed open space
overall and by phase. The open space plan shows all areas not being used for buildings,
parking, and circulation as open space, this will not work in the formal submittal.
Demonstrate compliance in the formal submittal how each type of open space proposed will
meet the listed design standards in this section including dimensional standards, amenities
provided, and separation from residential windows and service areas.
Response: Open space has been updated. Refer to document 016 Open Space
Calculations.
25. PLNG - Open Space
The gym, community lounge, outdoor plaza, and dog wash may be counted towards
required residential open space as indoor recreational areas. BMC 38.520.060.
Response: Acknowledged.
26. PLNG Building Design
Building massing and articulation BMC 38.530.040.C. Residential buildings must include
articulation features at appropriate intervals relative to the scale of the façade in order to
reduce the perceived massing of the building and add visual interest. At least three of the
features listed in this section must be employed at intervals relative to the individual
dwelling units or at a maximum of every 30 feet. The scale of the façade articulation
should be compatible with the surrounding context. Provide details in the narrative and
elevations.
Response: Refer to the Architectural Sheets.
27. PLNG - Blank Walls
Blank walls BMC 38.530.070. Untreated blank walls visible from a public street,
pedestrian-oriented space, common usable open space, or pedestrian pathway are
prohibited. Methods to treat blank walls are listed in this section and must be included in
the formal submittal.
Response: Refer to the Landscape Sheets.
28. Signs 38.560.060. The following on-premises signs may be permitted in R-5 with an
approved sign permit: 1. Subdivision and residential complex signs. For residential
subdivisions consisting of more than four residential lots and for residential complexes with
more than four dwellings and more than one building, one low profile, freestanding, sign
per development entrance may be permitted. No sign may exceed 16 square feet in area or
five feet in height from the finished grade. The sign must be set back at least five feet from
6 | P a g e
the property line. 2. Residential building signs. For properties used for multi-household
residential, one wall sign per street frontage may be permitted. No sign may exceed eight
square feet in area. Addressing is not subject to these standards.
Response: Acknowledged.