HomeMy WebLinkAbout120_A100_Building_K-Floor_PlansDW
CLOSET
CLOSET
LIVING
ROOM
FOYER
PORCH
BEDROOM A
BATH A
D
KITCHEN
W
CLOSET
CLOSET
LIVING
ROOM
FOYER
PORCH
BEDROOM B
BATH B
BEDROOM A
BATH A
TOILETCLOSET
2x6 FURR OUT
WH
WH 2x6 WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALL
2x6 WALL2x6 FURR OUTK-14377PURISTTOILET TISSUE HOLDERMETAL
METALTOILET TISSUE HOLDERPURISTK-14377 METALTOILET TISSUE HOLDERPURISTK-14377
REF.
PAN.
K-14377PURISTTOILET TISSUE HOLDERMETAL
METALTOILET TISSUE HOLDERPURISTK-14377
METALTOILET TISSUE HOLDERPURISTK-14377
2x6 WALL
2x6 WALLKITCHEN
K-14377PURISTTOILET TISSUE HOLDERMETAL
METALTOILET TISSUE HOLDERPURISTK-14377
METALTOILET TISSUE HOLDERPURISTK-14377
REF.
PAN.
4
A200
1
A200
2
A200
3
A200 64'-0"3'-7 1/2"8'-0"17'-10"31'-0"
11'-2"19'-10"
5'-7"5'-7"4'-8"3'-4"64'-0"25'-10"3'-3 1/2"3'-3 1/2"3'-6"3'-7 1/2"2'-2"3'-0"2'-11"2'-7 1/2"2'-10"5'-1"1'-10"5'-6"5'-112"4"4"10'-11"5'-812"13'-4 1/2"
512"3'-3 1/2"8'-0"29'-10"31'-0"
11'-2"19'-10"
5'-7"5'-7"4'-8"3'-4"12'-2"25'-8"5'-6"6'-11"2'-7 1/2"3'-1 1/2"3'-0"6'-10"1'-10"6'-0"5'-112"
15'-8"5'-8"3'-7"
5'-8"2'-7"1'-1012"1'-9"5'-8"9 1/2"
A
A
A
C
CC
A
A
B
L
B
C
C
CC
D
F
C
PG
P
F
5'-7"
C
C
CC
F
D
B
E1
E1
E1
A1
A1
A1
A2A1
A2E1
P3
P3
E1
E1 E1
E1
A1
A2
A1
A1
A1
A2
A1
A2
A1 A2
A1A1A2 A1
U
T
T
U
ABOVE
2'-5 1/2"10'-6 1/2"3'-7 1/2"10'-8"3'-912"3'-5 1/2"2'-312"1'-9"1'-9"2'-8 1/2"2'-8 1/2"
2'-7"2'-7"
2'-8 1/2"2'-8 1/2"
E1
6'-6"3'-3"3'-3"5'-2"7'-8"E1
A
6'-9"E1
A
A
A
L 6'-6"3'-3"3'-3"7'-8"A
A
A
22-1/2" x 30" ATTIC ACCESS
ABOVE WITH LADDER
22-1/2" x 30" ATTIC ACCESS
ABOVE WITH LADDER
5'-11 1/2"2'-4"
5'-11 1/2"
3'-10"5'-0"3'-2"1'-9"2'-012"A2
A2
14'-2 1/2"1'-6"5'-2"14'-2 1/2"A
8'-3 1/2"5'-5"1'-9"1'-9"3'-10"3'-7"2'-0"A2
A
E1
E13'-7"2'-0"A
512"
13'-4 1/2"5'-612"11'-1 1/2"
C
3'-3"
A
ABOVE
2'-4"
A
8'-3 1/2"3'-3"
1'-7 1/2"
4
A301
1
A301
8'-8"8'-8"A
A
C
6'-8"4:12
SLOPE
12:12
SLOPE
12:12
SLOPE
4:12
SLOPE
12:12
SLOPE
12:12
SLOPE
6:12
SLOPE10:12SLOPE10:12SLOPE10:12SLOPE10:12SLOPE6:12
SLOPE4'-0"4'-0"AT ALL AREAS WHERE THERE IS ROOFING
OVERBUILD, OPENINGS IN THE ROOF
DECKING BELOW MUST BE CUT OUT TO
ALLOW FOR PROPER ATTIC VENTILATION
7'-11 3/4"
VENTING NOT REQUIRED
CLOSE OFF ROOF DECKING AT
RIDGE, TYPICAL AT OVERHANGS
1'-0"1'-0"1'-0"11'-2"19'-10"29'-10"4"25'-10"1'-0"1'-0"37'-10"4"25'-10"21'-1"1'-0"64'-0"64'-0"1'-0"1'-0"1'-0"9'-11"8'-0"3"31'-0"
31'-0"
9'-11"9'-11"
1'-0"13'-0"12'-10"RIDGE VENT REQUIRED TO BE
CLOSED OFF FOR A MINIMUM
OF 4'-0" FROM FIRE PARTITION
BETWEEN UNITS
12'-10"13'-0"2'-0"1CL01-D-T/2CT01-T
1&2 BR COTTAGE TWIN ALT 1
THIS DRAWING IS THE PROPERTY OF NEQUETTE ARCHITECTS, INC. NO PERMISSIONS ARE GRANTED TO REUSE, REPRODUCE, OR ALTER, UNLESS GRANTED IN WRITING FOR A SPECIFIC PURPOSE BY NEQ.COTTAGES AT BOZEMANBOZEMAN, MTNEQUETTE PROJECT NUMBER: 20048DISTRIBUTION LOG
07/15/22 SITE PLAN SUBMISSION
07/07/23 SITE PLAN RESUBMISSION1
1
A100
Floor Plan
3/16" = 1'-0"
A1002
A100
Roof Plan
3/16" = 1'-0"
1
1
1