HomeMy WebLinkAbout112_A100_Building_F-Floor_PlansD W
CLOSET
CLOSET
LIVING
ROOM
FOYER
PORCH
BEDROOM A
D W
CLOSETLIVING
ROOM
FOYER
PORCH
BEDROOM A
CLOSET
WH
WH
BATH A 2x6 WALL2x6 WALL2x6 WALL
BATH A
2x6 WALL2x6 WALL2x6 WALL
METALTOILET TISSUE HOLDERPURISTK-14377
METALTOILET TISSUE HOLDERPURISTK-14377
METALTOILET TISSUE HOLDERPURISTK-14377
METALTOILET TISSUE HOLDERPURISTK-14377
KITCHEN
REF.
PAN.
KITCHEN
REF.
PAN.
K-14377PURISTTOILET TISSUE HOLDERMETAL
K-14377PURISTTOILET TISSUE HOLDERMETAL
C
1
A200
A
A
B
L
C
C
CC
D
F
E1
E1E1
A1
A1
A1
A2
A2
E1
E1
U
T
A
22-1/2" x 30" ATTIC
ACCESS ABOVE
A1
2
A200
25'-10"8'-0"4'-8"3'-4"25'-10"5'-2"6'-6"5'-0 1/2"3'-4"2'-2"3'-0"2'-10"6'-10"1'-10"5'-6"5'-1 3/4"7'-8"3'-3"3'-3"2'-7 1/2"P1
3'-3 1/2"3'-6"2'-6 1/2"10'-2 1/2"1'-9"1'-9"2'-8 1/2"2'-8 1/2"17'-10"31'-0"
11'-2"19'-10"
5'-7"5'-7"5'-11 1/2"2'-1 1/4"8'-0 3/4"
A
A
E1
A
E12'-10"P1
A2
512"
3'-10"
5'-8 1/2"13'-4 1/2"10'-11"
A1
D
A
A
B
L
C
C
CC
D
F
E1
E1E1
A1
A1
A1
A2
A2
E1
E1
U
T
A
22-1/2" x 30" ATTIC
ACCESS ABOVE
A1 25'-10"8'-0"4'-8"3'-4"25'-10"5'-2"6'-6"5'-0 1/2"3'-4"2'-2"3'-0"2'-10"6'-10"1'-10"5'-6"5'-112"7'-8"3'-3"3'-3"2'-7 1/2"3'-3 1/2"3'-6"2'-6 1/2"10'-2 1/2"1'-9"1'-9"2'-8 1/2"2'-8 1/2"17'-10"31'-0"
11'-2"19'-10"
5'-7"5'-7"5'-11 1/2"
A
A
E1
A
E1
2'-10"A2
512"
3'-10"
5'-8 1/2"13'-412"10'-11"
A1
4
A200 52'-0"3
A20052'-0"4"4"ABOVE1'-0"THIS WINDOW IS ELIMINATEDAT UNITS NOTED WITH AN (X)ON THE A001 I.D. DRAWINGTHIS WINDOW IS ELIMINATEDAT UNITS NOTED WITH AN (X)ON THE A001 I.D. DRAWING1'-10"3'-7"1'-10"3'-7"12'-5"12'-5"I
I 9'-11"9'-11"D
3'-8 1/2"
C
ABOVE
C
2'-1 1/4"8'-0 3/4"
D
ABOVE
D
3'-8 1/2"
C
ABOVE
4:12
SLOPE
10:12SLOPE10:12SLOPE12:12
SLOPE
12:12
SLOPE
12:12
SLOPE
4:12
SLOPE 10:12SLOPE10:12SLOPE12:12
SLOPE
12:12
SLOPE
12:12
SLOPE
4'-0"4'-0"RIDGE VENT REQUIRED TO BE
CLOSED OFF FOR A MINIMUM OF
4'-0" FROM FIRE PARTITION
BETWEEN UNITS
VENTING NOT REQUIRED CLOSE OFF
ROOF DECKING AT RIDGE, TYPICAL AT
OVERHANGS
31'-0"
1'-0"1'-0"
9'-11"1'-0"21'-1"
31'-0"
1'-0"52'-0"1'-0"1'-0"52'-0"2'-0"2'-0"8'-6"43'-6"VENTING NOT REQUIRED
CLOSE OFF ROOF DECKING AT
RIDGE, TYPICAL AT OVERHANGS
AT ALL AREAS WHERE THERE IS ROOFING
OVERBUILD, OPENINGS IN THE ROOF
DECKING BELOW MUST BE CUT OUT TO
ALLOW FOR PROPER ATTIC VENTILATION
9'-11"21'-1"8'-6"AT ALL AREAS WHERE THERE IS ROOFING
OVERBUILD, OPENINGS IN THE ROOF
DECKING BELOW MUST BE CUT OUT TO
ALLOW FOR PROPER ATTIC VENTILATION
1
A301
1 BR COTTAGE L TWIN ALT 1
1
A100
Plan
1/4" = 1'-0"A1002
A100
Roof Plan
1/4" = 1'-0"
THIS DRAWING IS THE PROPERTY OF NEQUETTE ARCHITECTS, INC. NO PERMISSIONS ARE GRANTED TO REUSE, REPRODUCE, OR ALTER, UNLESS GRANTED IN WRITING FOR A SPECIFIC PURPOSE BY NEQ.COTTAGES AT BOZEMANBOZEMAN, MTNEQUETTE PROJECT NUMBER: 20048DISTRIBUTION LOG
07/15/22 SITE PLAN SUBMISSION
07/07/23 SITE PLAN RESUBMISSION1
1
1
1
1