HomeMy WebLinkAbout014 L1.2 North Wallace Residence IRRIGATION DETAILSDRAWING NUMBER:PHASE:DATE:DRAWING TITLE:PROJECT NUMBER:DRAWN BY /CHECKED BY:REVISIONS:0"1"2"PERMIT SETGROVE 3 SF SUMMARYLIVING LEVEL843GARAGE LEVEL377UPPER LEVEL1228SOLARIUM345TOTAL2793GARAGE SF568L1.2IRRIGATIONDETAILS22-000545NORTHWALLACERESIDENCES428 NORTH WALLACENO.DESCRIPTIONDATE1 1/2" = 1'-0"SHUT OFF VALVEFINISH GRADE18" BELOW GRADE10" DIAMETER ROUND VALVEBOX, SEE SPECIFICATIONSSET BOX 2" ABOVE GRADE AT SHRUBSSET BOX FLUSH TO GRADE AT LAWNISOLATION VALVE ASSPECIFIEDFOUR COMMONBRICK SUPPORTS10" DIA. PVC PIPE EXTENSION,LENGTH AS REQUIREDPVC MAIN LINESLIP/THREAD COUPLING6" SCHEDULE 80 THREADEDNIPPLEP-RE-BOZ-031DOUBLE CHECK VALVE (DCVA)NTSFINISH GRADE AT LIP OF BOX IN TURF ANDPAVED AREAS (1" BELOW LIP IN ALL OTHER AREAS)VALVE BOX: REFER TO IRRIGATION SHEETNOTES OR SPECIFICATIONSVALVE BOX COVERBRASS UNIONBRASS NIPPLES6" MIN. CLEARANCEBACKFLOW PREVENTORPEA GRAVEL (INSTALL MIN. 2 CU. FT.BELOW BACKFLOW PREVENTOR)PVC MAINLINE2P-RE-BOZ-093/4" X 3" PROTECTIVEGRAVEL SUMP3/4" CLOSE NIPPLE2" PVC SLEEVEREDUCING TEE(2 CU. FT.)PVC NIPPLEMAIN LINE12" MIN.24" MIN.FINISH GRADEVALVE MARKERRAINBIRD #63100MANUAL DRAIN VALVE DETAILNTSCHAMPION #200-075 (OR EQ.)BRASS ANGLE VALVE WITHUNION. INSTALL AT ALLMAINLINE LOW POINTS TOFACILITATE COMPLETEMAINLINE DRAINAGE.3P-CO-OUR-19NOTE: ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO "IN-LINE" WIRE SPLICESALLOWED. TAPE AND BUNDLE WIRES EVERY 20 FEET. PROVIDE EXPANSION COILS AT EACHVALVE - WRAPPING WIRE AROUND 1/2" PIPE 15 TIMES. ALL THREADED CONNECTIONS SHALLBE MADE WITH TEFLON TAPE.VALVE BOX & COVER;REFER TO IRRIGATIONSHEET NOTES AND/ORDETAILS, PROVIDEVALVE BOX EXTENSIONSAS REQUIRED.1"FINISH GRADE AT LIP OFBOX IN TURF AND PAVEDAREAS; 1" BELOW LIP INALL OTHER AREASSCH. 80 PVC UNIONLATERAL PIPE TOSPRINKLERSELECTRIC CONTROL VALVESCH.80 PVC UNIONSCH. 40 PVC & FITTINGSUPPORT VALVEBOX WITH 4BRICKS, TYP.3"PROVIDE A MIN. 3"CLEARANCELOW VOLTAGE WIRESPRESSURE MAINLINESCH. 40 PVC FITTINGMINIMUM 6" DEPTHOF PEA GRAVELELECTRONIC CONTROL VALVE1" = 1'-0"5P-RE-BOZ-12POP-UP SPRINKLER HEADN.T.S.30°-45°3"WALK OR CURBFINISHED GRADESPRINKLER BODY1-SCH. 40 & 2-MARLEXSTREET ELLS ORPRE-ASSEMBLED SWINGJOINT W/ SCH. 40 SWIVELELLSTHREADED RISER(IF NEEDED)LATERAL LINE FITTINGP-RE-BOZ-0561 1/2" = 1'-0"DRIP VALVE W/BASKET FILTER2" ABOVE GRADE ATSHRUBS.SET BOX FLUSHAT TURF.3"512"20" x 14" JUMBO PLASTICVALVE BOXPVC TRUE UNION BALLVALVECONTROLLER WIRE WITH 30 INCH LINEARLENGTH OF COIL, WITH PLASTIC I.D. TAGAND WATERPROOF CONNECTORSRCV AS SPECIFIEDBASKET FILTER AS SPECIFIEDPRESSURE REGULATOR ASSPECIFIEDPVC UNION W/ SHORTNIPPLES3" MIN.45° DOWN AS REQ. TOLATERAL PIPE DEPTHOUTLET PIPE SAME SIZE AS VALVE,24" MIN. LENGTH TO FIRST FITTING12" BELOWGRADESCH. 80 RISERSxT TEE W/ 2" NIPPLEAT MAINLINEPROVIDE FOUR BRICKS TOSUPPORT VALVE BOX.7P-RE-BOZ-07MFMFMFREMOTE CONTROL VALVEWITH DISC FILTER AND PRVTechline® HCVXR DRIPLINETechline® START CONNECTIONISLAND PERIMETERMANUAL FLUSH VALVE PLUMBEDTO Techline® HCVXR (TYP)PVC OR POLY SUPPLY HEADERSEE SPECIFICATIONSFOR ROW SPACINGPERIMETER LATERALS 2"TO 4" FROM EDGENOTE:1.RECOMMENDED MINIMUM FILTRATION: 120 MESH2.PRESSURE AT FLUSH VALVE SHALL BE MIN 21.8PSI3.HIGH CHECK VALVE (MAX 8.5' OF WATER(ELEVATION CHANGE))4.REFER TO MAXIMUM LENGTH OF A SINGLELATERAL CHARTHCVXR LITE ISLAND LAYOUTNTS81 1/2" = 1'-0"QUICK COUPLING VALVE IN BOXQCV2" MAX.1" MIN.6" MIN.FLUSH IN LAWN AREAS.2" IN SHRUB AREAS.12" MAX.10" DIAMETER VALVE BOX.HEAD BRAND "QVC" ONLID WITH 2" HIGHCHARACTERS.FINISHED GRADETWO STAINLESSSTEEL CLAMPS1/2" x 36" GALV.STEEL PIPETHREE PVC SCH. 80ELLS.QUICK COUPLING VALVE ASSPECIFIEDGALV. NIPPLE, LENGTH AS REQ.6" DEEP LAYER OF 3/4"CRUSHED ROCK3" PVC SCHEDULE 80 NIPPLE12" PVC SCHEDULE 80 NIPPLEP-RE-BOZ-024IRRIGATION SPECIFICATIONS1.THIS PLAN IS DIAGRAMMATIC; ALL PIPING, VALVES, ETC. SHALL BE INSTALLED IN SHRUBBEDS WHERE POSSIBLE AND SHALL FOLLOW THE PLAN AS CLOSE AS IS PRACTICAL.2.LOCATE ALL MAINLINES WITHIN THE PROJECT LIMITS.3.PIPE SIZES ARE CONSTANT BETWEEN PIPE SIZE CALL-OUTS. ALL LATERIAL PIPES SHALL BEINSTALLED AT 12" DEPTH AND 24" DEPTH UNDER PAVED AREAS. MAIINLINE PIPE SHALL BEINSTALLED AT 18" BELOW GRADE AND 24" BELOW PAVED AREAS.4.REFER TO DETAILS FOR ADDITIONAL INFORMATION.5.ALL PIPING AND WIRING UNDER PAVED AREAS SHALL BE HOUSED IN CLASS 200 PVCSLEEVES INSTALLED AT A 24" DEPTH. SIZE SLEEVES AS NEEDED TO ACCOMMODATE PIPEAND WIRES, UNLESS OTHERWISE SPECIFIED ON DRAWING.6.CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED TO OBTAIN FULL COVERAGE.LANDSCAPE ARCHITECT RESERVES THE RIGHT TO MAKE NOZZLE CHANGES AS NEEDED ATNO ADDITIONAL COST. ADJUST HEAD POSITIONS AND ADD OR DELETE HEADS AS NEEDEDDEPENDING ON ACTUAL FIELD CONDITIONS.7.ALL MANUAL, GATE AND ELECTRICAL VALVES AND OTHER UNDERGROUND EQUIPMENTSHALL BE HOUSED IN NELSON, AMETEK OR EQUAL RECTANGULAR VALVE BOXES.8.NO IN-LINE WIRE SPLICES ALLOWED. SUPPLY VALVE BOXES AT ALL ELECTRICAL JUNCTIONS.TAPE AND BUNDLE WIRES EVERY 25 LINEAR FEET.9.CONTRACTOR IS RESPONSIBLE FOR COMPLETE SYSTEM DRAINAGE. INSTALL KING BROS.1/2" AUTOMATIC DRAIN VALVES AT LATERAL LINE LOW POINT(S). INSTALL MANUAL DRAINSAT ALL MAINLINE LOW POINT(S) AND WHERE INDICATED ON PLAN. CONTRACTOR SHALLPROVIDE ADJUSTABLE CHECK VALVES ON ANY IRRIGATION HEAD THAT EXPERIENCES LOWHEAD DRAINAGE.10.ALL THREADED PIPE CONNECTIONS SHALL BE MADE USING TEFLON TAPE WRAPPED ATLEAST THREE TIMES AROUND PIPE THREADS.11.ALL GATE AND ELECTRIC VALVES SHALL BE INSTALLED WITH UNIONS ON THE DOWNSTREAMEND OF THE VALVE (REFER TO DETAILS).12.ALL PIPE SHALL HAVE A FIRM UNIFORM BEARING FOR THE ENTIRE LENGTH OF EACH LINE,FREE OF ROCKS OR DEBRIS. ALL TRENCHES CONTAINING PIPE AND/OR WIRES SHALL BEBACKFILLED WITH CLEAN TOPSOIL, FREE OF ALL LUMBER, RUBBISH AND ROCKS OVER 1" INSIZE, OR CLEAN SAND IF CLEAN TOPSOIL IS NOT AVAILABLE.13.CONTRACTOR SHALL PROVIDE OWNER WITH ONE SET OF AS-BUILT RECORD DRAWINGSSHOWING EXACT ACTUAL LOCATIONS OF ALL SPRINKLER EQUIPMENT. CONTRACTOR SHALLORIENT OWNER WITH COMPLETE SYSTEM AND CONTROLLER OPERATIONS, ANDWINTERIZATION PROCEDURES.14.CONTRACTOR SHALL SUPPLY AND INSTALL ALL EQUIPMENT SHOWN ON THE PLANS ANDINDICATED IN THE SPECIFICATIONS TO ACHIEVE PROPER OPERATION OF SAID EQUIPMENT.ALL EQUIPMENT INSTALLATIONS, ELECTRICAL AND PLUMBING CONNECTIONS SHALL BE INCONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES, THESE SPECIFICATIONS,AND THE MANUFACTURERS RECOMMENDATIONS WHETHER INDICATED ON THE DRAWINGSOR NOT.15.CONTRACTOR SHALL INCLUDE IN HIS BID ONE FALL WINTERIZATION AND ONE SPRINGACTIVATION OF IRRIGATION SYSTEM. THESE ACTIVITIES SHALL BE INCLUDED AS PART OFOWNER ORIENTATION PROCEDURES. ANY DAMAGE TO THE IRRIGATION SYSTEM OR THELANDSCAPE AS A RESULT OF FAILURE TO COMPLY WITH THESE REQUIREMENTS SHALL BETHE SOLE RESPONSIBILITY OF THE CONTRACTOR.16.CONTRACTOR SHALL GUARANTEE IN WRITING ON HIS COMPANY LETTERHEAD ALLMATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE FULL YEAR FOLLOWINGACCEPTANCE OF SYSTEM INSTALLATION.17.BACKFLOW PREVENTOR SHALL BE INSPECTED AND TESTED BY A CERTIFIED BACKFLOWDEVICE INSPECTOR. PROVIDE OWNER WITH ONE COPY OF APPROVAL CERTIFICATE.3-6" BELOWMIN. 12" BELOW GRADETECHLINE START CONNECTION (SWING JOINT RISER)N.T.S.34" MIN. TRIPLE SWINGJOINTFINISH GRADETECHLINE COMBINATION TEE(MODEL TL075FTEE)DRIPLINE TUBINGPVC TEE (SXSXT) OR90° (SXT)LATERAL LINE, TYP.NOTE: EACH CONNECTION ISCAPABLE OF MAX 10 GPM9P-RE-BOZ-10PERMITTGAVAUGUST 24, 20231DRAFTIRRIGATION2022-07212SITE PLAN2023-0823MONTANAL A N D SCAPE ARCHITECTLICENSEDNo. 20067MARK S. GARFF