HomeMy WebLinkAbout007 North Wallace Residences NARRATIVEPLUM DESIGN LAB | 875 BRIDGER DRIVE UNIT F | 406-624-6786 Pg1 Concept Site Plan, 12.10.2021 North Wallace Residences Owner: David H. Viciedo Proposed Site Address: 428 N. Wallace Avenue, Bozeman, MT 59715 Legal: Babcock and Davis ADD, S07, T02 S, R06 E, Block 7, 0.299 Acres, W2 Lot 3 Table of Contents 1.Project Summary 2.Site Programming and design elements 3.Requests for Staff Project Summary Plum Design lab was contracted to perform a site design with focus on the site relationships configuring a total number of 11 residential units on a single plot of land currently owned by David Viciedo. The owner currently resides in the existing single-family home currently on the site. This initial design demonstrates a configuration of 2 Duplex units with garages, 1 ADU with designated parking, and 1 single family residence. The grading and property boundary was generally created via online tools and shall be verified going forward if the city considers the project acceptable. Existing Residence and Garage (Street View) PLUM DESIGN LAB | 875 BRIDGER DRIVE UNIT F | 406-624-6786 Pg2 Property Vicinity Map Site Location Map PLUM DESIGN LAB | 875 BRIDGER DRIVE UNIT F | 406-624-6786 Pg3 Site Program Existing Residence and Area Calculations ● Existing Residence is Approximately 600 sq ft ● Existing Garage is Approximately 300 sq ft ● Site records indicate .299 acres, approximately 13,024 sq ft ● Fronting Property Boundary Line is 62.5’ per warranty deed Proposed 4 Buildings with 11 Residential Bedrooms ● 2 duplexes (6 beds) ● 1 ADU (1 bed) ● 1 Single family residence (4 beds) Each Residential Unit will have the following ● (1) 4-bedroom Single family residence, 2,900 – 3,000 gross square feet ● (1) 1-bedroom ADU, 500 - 600 gross square feet ● (2) 3-bedroom duplex units 3,000 – 3,400 gross square feet ● 2-1/2 Bathrooms in the Residence ● 1 Bathroom in ADU unit located toward the rear of the lot ● 2-1/2 Bathrooms per duplex unit ● Connective decks and patios to the site, upper decks toward the drive aisles. ● Standard sized garage of 23 x 23 Intensity: Total estimated square feet of finished area: 6,731 sq ft. Lot size: 13,024 6,731 / 13,024 = 0.52 FAR (0.75:1 allowed per 38.320.030.C in R-2) Lot Coverage: Total estimated square feet of footprint proposed: 3,414 sq ft Lot size: 13,024 3,414 / 13,024 = 0.26 (40% allowed per 38.320.030.C in R-2) Zoning Map (M-1 Designation) PLUM DESIGN LAB | 875 BRIDGER DRIVE UNIT F | 406-624-6786 Pg4 Planning: Road access via Wallace Avenue with compliant Fire truck access is provided. We have indicated on the site plan our proposed fire access. Can staff please provide general feedback on the acceptance of this method or identify further requirements for compliance. The project proposes pedestrian access via a sidewalk of 5’-0” wide located on the North side of the duplex units and single-family residence. This access provides egress to each unit and the open space with enhanced landscaping features and planters surrounding the area. Please confirm that this is acceptable. Landscaping features and general pedestrian features are provided on the site plan for review. Setbacks: Front: 15’ Sides: 5’ Rear: 28’ HT Max: 37’-3” HT Totals: 4:12 = 27’-6” – Residence 8:12 = 27’-8” – ADU/Garage (per accessory building diagram 38.360.030.G) 4:12 = 38’-8” – Duplex Parking Required for each unit: ● 3 parking spaces are required per unit for the 3-bedrooms, 2 are provided in each garage, while 2 parking stalls are provided for the third parking space requirement. ● 4 parking spaces are required for dwellings with more than three bedrooms. The single-family residence has 4 bedrooms. 2 spaced are provided in the garage below the ADU and 2 more compact parking stalls are provided outside the garage. ● 1 parking space is required for the ADU. This is provided next to the parking stalls. Note: Because of the lot frontage being 62.5’ wide we were unable to create an on- street parking stall outside the vision triangle. Please correct us if this is incorrect. Open Space: Residence: 293 sq ft of open space is required for the single-family residence, 2,937 * 0.1 = 293 | 327 sq ft is provided Garage/ADU: 53 sq ft of open space is required for the 1-bedroom dwelling (ADU), 533 * 0.1 = 53 | 284 sq ft is provided Duplex: 326 sq ft of open space is required per unit for the 3-bedroom units (2), 3,261 * 0.1 = 326 | 427 sq ft is provided Parkland: .3 acres of open space has been calculated as required for open space with the 11 residential dwellings proposed, per Table 38.420.020.A (BMC). This is equal to 13,068 sq ft of open space. The site is only 13,024 sq ft in size. Please confirm this method of calculation is correct. Please provide total Cash in Lieu payment amount due. PLUM DESIGN LAB | 875 BRIDGER DRIVE UNIT F | 406-624-6786 Pg5 Engineering Items: Access from Wallace with a fire apparatus on a 20’-0” wide drive aisle. As noted on site plan drive aisle has a length of 149.92’. Please confirm if this approach is acceptable without a turnaround. We propose extending both water Main and Sewer Line Main (8” dia.) from North Wallace to the residences along the South side of this corridor. Drive access is proposed for the units on the provided site plan. We believe the lot can hold the density per the overall land use planning of this area. We are proposing a 20’-0” wide drive access ingress and egress from the site serving the residences. Fire Lanes will be posted with signs and paint indicating no parking areas. Snow storage and water retention areas are proposed on the site plan. Full calculations will be provided via preliminary site plan. Lighting: All pedestrian lighting will be provided from the residence entries for the road and sidewalk circulation paths. PLUM DESIGN LAB | 875 BRIDGER DRIVE UNIT F | 406-624-6786 Pg6 Perspective View West Elevation East Elevation South Elevation North Elevation