Loading...
HomeMy WebLinkAboutCOTTONWOOD_(OXBOW) APARTMENTS_Water-Sewer-Record-Dwg484548504860487048454850486048704866.281+004865.81 4867.621+254865.23 4867.201+504864.87 4866.571+752+004864.19 4866.39 4863.84 4866.002+254863.48 4865.602+504863.19 4865.132+753+004862.86 4864.77 4862.56 4863.443+254862.17 4863.123+504861.76 4863.133+754+004861.30 4862.90 4861.06 4862.364+254860.87 4861.474+50PROPOSED GROUNDELEV. AT ALIGNMENTEXISTING GROUND ELEV.(APPROX.) AT ALIGNMENTPROPOSED GROUND ATALIGNMENTEXISTING GROUND (APPROX.)AT ALIGNMENTEXISTING 8" WATERMAIN & TEE.EXISTING 8" WATER MAINSTUBBED INTO PROPERTY.ELEVATION AT CONNECTIONPOINT IS APPROXIMATE.CONTRACTOR TO VERIFY.STA: 1+35.09 OFF: -5.31 8" GATE VALVE STA: 1+35.85 OFF:-6.40 8" 11.25 DEG BEND BLDG #5 WATER SERVICE STA: 3+24.81 OFF:-5.50 8"X8"X4" TEE BLDG #7 WATER SERVICE STA: 3+39.56 OFF:-5.50 8"X8"X4" TEE BLDG #7 FIRE SERVICE STA: 3+29.86 OFF:-5.50 8"X8"X6" TEE BLDG #5 FIRE SERVICE STA: 3+34.27 OFF:-5.50 8"X8"X6" TEE STA: 1+38.52 OFF:-7.52 8" 22.5 DEG BEND R.O.W BOUNDARY OPEN SPACE BOUNDARY PIPE CROSSING: STORM DRAIN STA:2+15.85 PIPE CROSSING: SEWER SERVICE STA:3+62.57 PIPE CROSSING: STORM DRAIN STA:4+43.46INSULATE STORM XING4" XPS RIGIDFOAM OVER 6" OF SANDINSULATE STORM XING4" XPS RIGIDFOAM OVER 6" OF SAND4.01 18" MIN. CVR 4.91 18" MIN. CVR 1.87 18" MIN. CVR FG @ 5.5' L. (TYP.)8.18' (6.5' MIN)316.5'8" CL51 DIP - WATER MAINTYPE 'A' TRENCH BACKFILLTYPE 1 PIPE BEDDINGUPBUILDING #5APARTMENTTYPE B8,847 SFFFE = 4,864.004675 LOYAL DR.UNITS 1-28BUILDING #6APARTMENTTYPE A3,895 SFFFE = 4,866.404685 LOYAL DR.UNITS 1-121+002+003+004+005+00SSDSTSTSTSTSTSTST STSTSTSTST ST STSTWMWMWMWMWMWMWMWMWMSSSSSSSSSSFFFFFWSWSWSWSSSSSSS SHYDSBPBPBPBPTFFFFWSWSWSBPBPBPBPSSWVWVWVWVWVFFWSBPBPBPBPBPBP WVWVcoBPBPBPBPWVOSWWVWVNEW 30.00'PUBLIC UTILITYEASEMENT11.0SSMH-02 (48"∅)SSMH-01 (48"∅)OPEN SPACELOT 1 0.25 AC.LOT 2BLK. 32.51 AC.ABCDABCD1234512345COPYRIGHT GGLO. ALL RIGHTS RESERVED.ORIGINAL SHEET SIZE IS 24"x36"SHEET NO.SHEET TITLEGGLO PROJECT MANAGER:GGLO PRINCIPAL IN CHARGE:PROJECT NO.:OWNER APPROVAL:MARKDATEDESCRIPTION07-31-2023 - RECORD DRAWINGSREVISIONSPROJECT:OWNER:PROJECT ADDRESS:1301 First Avenue, Suite 301Seattle, WA 98101http://www.gglo.comCONNIE ST. GEORGETOM SHELDONCOTTONWOOD SUBDIVISION5500 S COTTONWOOD RDBOZEMAN, MT 59718THE COTTONWOODPROJECTTHE COTTONWOOD PROJECT, LLC3112 LOS FELIZ BOULEVARDLOS ANGELES, CALIFORNIA 90039MARKDATEDESCRIPTION2019111.01®RECORD DRAWINGC310AWATER MAIN PROFILESITE PLAN PACKAGE 'A'1C310AWATER MAIN PROFILEHORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 4'COB STANDARD NOTES:1.ALL CONSTRUCTION WILL CONFORM TO MPWSS, (LATEST) EDITION,AND COB MODIFICATIONS TO MPWSS.2.ANY EXISTING OR NEW VALVES WHICH CONTROL THE COB'S WATERSUPPLY SHALL BE OPERATED BY COB PERSONNEL ONLY.3.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT AMINIMUM OF 24-HOURS PRIOR TO BEGINNING ANY WORK.4.CONTRACTOR SHALL FIELD-VERIFY LINE AND GRADE OF EXISTINGCONNECTIONS PRIOR TO CONSTRUCTION.11.25° BEND22.50° BENDREMOVE BLOWOFF ASSEMBLYCONNECT TO EXISTING STUB.NEW6" G.V.NEW4" G.V.NEW4" G.V.NEW6" G.V.NEW8" G.V.NEW 8" WATER MAIN 484548504860487048454850486048704860.874861.474+504860.48 4860.804+755+004860.07 4860.04 4859.65 4859.555+254858.55 4859.485+504856.96 4859.175+756+004855.50 4858.89 4855.21 4858.716+254854.96 4858.726+504854.38 4858.086+757+004854.59 4857.24 4855.02 4857.227+254855.58 4857.667+504856.02 4858.147+758+00PROPOSED GROUNDELEV. AT ALIGNMENTEXISTING GROUND ELEV.(APPROX.) AT ALIGNMENTPROPOSED GROUND ATALIGNMENTEXISTING GROUND(APPROX.) ATALIGNMENTSTA: 7+57.10 OFF: -8.96 8" GATE VALVE BLDG #4 FIRE SERVICE STA: 5+75.63 OFF:-5.49 8"X8"X6" TEE HYDRANT LEAD STA: 4+51.89 OFF:-5.50 8"X8"X6" TEE STA: 7+55.29 OFF:-8.93 8" 45 DEG BEND STA: 7+51.88 OFF:-5.50 8" 45 DEG BEND BLDG #3 FIRE SERVICE STA: 5+55.32 OFF:-5.51 8"X8"X6" TEE BLDG #4 WATER SERVICE STA:5+79.16 2" SERVICE SADDLE BLDG #3 WATER SERVICE STA: 5+52.61 OFF:-5.50 8"X8"X4" TEE BLDG #2 WATER SERVICE STA:6+90.42 2" SERVICE SADDLE BLDG #1 WATER SERVICE STA:7+42.31 2" SERVICE SADDLE R.O.W BOUNDARY BURIED POWER, GASUTILITIES, & CONDUIT.CONTRACTOR TOVERIFY LOCATIONOPEN SPACE BOUNDARY PIPE CROSSING: STORM DRAIN STA:6+03.71 PIPE CROSSING: SANITARY SEWER STA:5+86.08 EXISTING 8" WATERMAIN STUBBED INTOPROPERTYPIPE CROSSING: SANITARY SEWER STA:7+27.31INSULATESTORM XING4" XPS RIGIDFOAM OVER 6"OF SAND4.35 18" MIN. CVR 5.02 18" MIN. CVR INSULATESTORM XING4" XPS RIGIDFOAM OVER 6"OF SAND2.34 18" MIN. CVR 2.09 18" MIN. CVR INSULATESTORM XING4" XPS RIGIDFOAM OVER 6"OF SANDFG @ 5.5' L. (TYP.)6.58' (6.5' MIN)307.9'8" CL51 DIP - WATER MAINTYPE 'A' TRENCH BACKFILLTYPE 1 PIPE BEDDINGSTA: 6+87.41 OFF:-5.50 BLDG #2 FIRE SERVICE STA: 4+54.57 OFF: -5.50 8" GATE VALVEIE:4853.72BUILDING #1FITNESS CENTER2,499 SFFFE = 4,857.204680 W GARFIELD STBUILDING #3APARTMENTTYPE B8,847 SFFFE = 4,860.404670 W GARFIELD STUNITS 1-28MEV-1EV-1EV-14+005+006+007+008+00SSDSTST STSTSTSTSTSTSTSTST ST ST STSTWM WMWMWMWMWMWMWMSSSSSSSSSSSSSSSSSSSSHYDSWSWSWSFFFFWSWSWSSS BPBPBPBPBPGASGASGASGASGASGASGASGASGASBPBPSSOSWWSWSWSWSOSWOSWWVWVWVWVWVWSWSWSSSBPBPBPBPBPBPBPBPBPBPPHCNDTCNDTCNDTSWVSS WVFFFFFFFFFBP BP BP BPPHNEW 30.00'PUBLIC UTILITYEASEMENT11.0SSMH-02 (48"∅)SSMH-03 (60"∅)LOT 1OPEN SPACELOT 1 0.25 AC.ABCDABCD1234512345COPYRIGHT GGLO. ALL RIGHTS RESERVED.ORIGINAL SHEET SIZE IS 24"x36"SHEET NO.SHEET TITLEGGLO PROJECT MANAGER:GGLO PRINCIPAL IN CHARGE:PROJECT NO.:OWNER APPROVAL:MARKDATEDESCRIPTION07-31-2023 - RECORD DRAWINGSREVISIONSPROJECT:OWNER:PROJECT ADDRESS:1301 First Avenue, Suite 301Seattle, WA 98101http://www.gglo.comCONNIE ST. GEORGETOM SHELDONCOTTONWOOD SUBDIVISION5500 S COTTONWOOD RDBOZEMAN, MT 59718THE COTTONWOODPROJECTTHE COTTONWOOD PROJECT, LLC3112 LOS FELIZ BOULEVARDLOS ANGELES, CALIFORNIA 90039MARKDATEDESCRIPTION2019111.01®RECORD DRAWINGC311AWATER MAIN PROFILESITE PLAN PACKAGE 'A'1C311AWATER MAIN PLAN & PROFILEHORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 4'COB STANDARD NOTES:1.ALL CONSTRUCTION WILL CONFORM TO MPWSS, (LATEST) EDITION,AND COB MODIFICATIONS TO MPWSS.2.ANY EXISTING OR NEW VALVES WHICH CONTROL THE COB'S WATERSUPPLY SHALL BE OPERATED BY COB PERSONNEL ONLY.3.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT AMINIMUM OF 24-HOURS PRIOR TO BEGINNING ANY WORK.4.CONTRACTOR SHALL FIELD-VERIFY LINE AND GRADE OF EXISTINGCONNECTIONS PRIOR TO CONSTRUCTION.REMOVE BLOWOFFASSEMBLY AND CONNECTTO EXISTING STUBNEW HYDRANTASSEMBLY.BURY EL = 4861.50NEW 8" G.V.NEW 45° BEND.NEW 45° BEND.NEW 2" CURBSTOP.NEW 6" G.V.NEW 6" G.V.NEW 4" G.V.NEW 2" TRAFFICRATED CURBSTOP.NEW 6" G.V.NEW 2" TRAFFICRATED CURBSTOP.NEW 8" WATER MAIN 484248504860487048424850486048704863.484865.602+504863.194865.132+753+004862.864864.774862.564863.443+254862.174863.123+504861.764863.133+754+004861.304862.904861.064862.364+254860.87 4861.474+504860.48 4860.804+755+004860.07 4860.04 4859.65 4859.555+254858.55 4859.485+504856.96 4859.175+756+004855.50 4858.89 4855.21 4858.716+254854.96 4858.726+504854.38 4858.086+757+004854.59 4857.24 4855.02 4857.227+254855.58 4857.667+504856.02 4858.147+758+00PROPOSED GROUNDELEV. AT ALIGNMENTEXISTING GROUND ELEV.(APPROX.) AT ALIGNMENTPROPOSED GROUND ATALIGNMENTEXISTING GROUND (APPROX.)AT ALIGNMENTSSMH-01 (48"∅)STA:3+14.88 OFF:5.50RRIM:4864.23IE OUT (N):4857.60 8" SSMH-02 (48"∅) STA:4+95.80 OFF:5.50R RIM:4860.23 IE IN (S):4853.90 8" IE OUT (N):4853.71 8" SSMH-03 STA:7+52.52 OFF:5.50R RIM:4857.96 IE IN (S):4850.06 8" IE OUT (N) 4845.02* *CONTRACTOR TO FIELD VERIFY PRIOR TO PROCURING MANHOLE.257' of 8" @ 1.42%181' of 8" @ 2.05%BLDG #7 SS SERVICE6" SDR 26 PVCSTA:3+18.88SEE DETAIL 2/C404A, TYP.PIPE CROSSING: WATER LINESTA:3+38.88 BLDG #5 SS SERVICE6" SDR 26 PVCSTA:3+62.57 PIPE CROSSING: STORM DRAIN STA:4+43.46 PIPE CROSSING: WATER LINE STA:5+76.09 PIPE CROSSING: WATER LINE STA:5+79.09 BLDG #3 SS SERVICE 6" SDR 26 PVC STA:5+86.05 BUILDING #4 SS SERVICE 4" SDR 26 PVC STA:5+36.61 BLDG#2 SS SERVICE 4" SDR 26 PVC STA:6+32.85 PIPE CROSSING: STORM DRAIN STA:6+41.33 BLDG #1 SS SERVICE 4" SDR 26 PVC STA:7+27.30 PIPE CROSSING: WATER LINESTA:3+29.87 1.55 DROP MANHOLE PERDETAIL 3/C404A.BURIED POWER & GASUTILITIES.CONTRACTOR TOVERIFY LOCATIONEXISTING 8" SEWERSANITARY SEWER MANHOLEPER DETAIL 1/C404A.R.O.W BOUNDARY CITY PARK BOUNDARY CITY PARK BOUNDARYSANITARY SEWER MANHOLEPER DETAIL 1/C404A.FG @ 5.5' R. (TYP.)IE:4857.56IE:4858.56IE:4854.32IE:4853.53IE:4852.78IE:4851.18INSULATE STORM XING4" XPS RIGID FOAMOVER 6" OF SANDINSULATE STORM XING4" XPS RIGID FOAMOVER 6" OF SAND1.501.52 PIPE CROSSING: WATER LINE STA:6+87.42 PIPE CROSSING: WATER LINE STA:6+92.67 1.65 1.55 1.56 INSULATESTORM XING4" XPS RIGIDFOAM OVER 6"OF SANDPIPE CROSSING: STORM DRAIN STA:6+03.71APPROX HIGHGROUNWATERADA UNITBUILDING #2CLUBHOUSE6,907 SFFFE = 4,860.104650 W GARFIELD STBUILDING #1FITNESS CENTER2,499 SFFFE = 4,857.204680 W GARFIELD STBUILDING #3APARTMENTTYPE B8,847 SFFFE = 4,860.404670 W GARFIELD STUNITS 1-28BUILDING #5APARTMENTTYPE B8,847 SFFFE = 4,864.004675 LOYAL DR.UNITS 1-28MEV-1EV-1EV-111.752.004.00STSTco3+004+005+006+007+008+00SSSDSTSTSTSTSTST STSTSTSTSTSTSTSTST ST ST ST ST STSTSTSTSTSTSTDWMWMWMWMWMWMWMWMWMWMWMWMWMSSSSSSSSSSSSSSSSSSSSSSFFFFFWSWSWSWSSSSSSSSHYDSSS coWSWSWSFFFFFFFFFWSWSWSWSWSWSWSWSSS SS BPBPFFFFFFFFFWSWSWSWSWSWSWSGASGASGASGASGASGASGASGASGASGASGASGASSSSSOSWWSWSWSWSOSWOSWWVWVWVWVWVWVWVWSWSWSWSWSWSWSWSSSSSBPBPBPBPBPBPBPBPBPBPBPBPBPPHCNDTCNDTCNDTCNDTSSSWVWVWVcococoSS SS WVFFFFFFFFFFFFFFBP BP BP BP BP BPPHNEW 30.00'PUBLIC UTILITYEASEMENT11.0SSMH-02 (48"∅)SSMH-03 (60"∅)SSMH-01 (48"∅)LOT 1BLK. 32.42 AC.OPEN SPACELOT 1 0.25 AC.LOT 2BLK. 32.51 AC.ABCDABCD1234512345COPYRIGHT GGLO. ALL RIGHTS RESERVED.ORIGINAL SHEET SIZE IS 24"x36"SHEET NO.SHEET TITLEGGLO PROJECT MANAGER:GGLO PRINCIPAL IN CHARGE:PROJECT NO.:OWNER APPROVAL:MARKDATEDESCRIPTION07-31-2023 - RECORD DRAWINGSREVISIONSPROJECT:OWNER:PROJECT ADDRESS:1301 First Avenue, Suite 301Seattle, WA 98101http://www.gglo.comCONNIE ST. GEORGETOM SHELDONCOTTONWOOD SUBDIVISION5500 S COTTONWOOD RDBOZEMAN, MT 59718THE COTTONWOODPROJECTTHE COTTONWOOD PROJECT, LLC3112 LOS FELIZ BOULEVARDLOS ANGELES, CALIFORNIA 90039MARKDATEDESCRIPTION2019111.01®RECORD DRAWINGC314ASEWER MAIN PROFILESITE PLAN PACKAGE 'A'1C314ASEWER MAIN PLAN & PROFILEHORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 4'NORTHNEW 8" SEWER MAINNEW CLEANOUT.IE OUT= 4854.71±IE IN = 4854.96±NEW GREASEINTERCEPTORNEW VENT LINES.SEE PLUMBING.SEE PLUMBING FORGREASE WASTECONNECTION.NEW 4" SANITARYSERVICE @ 2% MIN.NEW 4" SANITARYSERVICE @ 2% MIN.NEW CLEANOUT.CONNECT TO EXISTING SANITARYSTUB. FIELD VERIFY INVERT.NEW 4" SANITARYSERVICE @ 2% MIN.NEW 6" SANITARYSERVICE @ 1% MIN.NEW 6" SANITARYSERVICE @ 1% MIN.NEW 6" SANITARYSERVICE @ 1% MIN.NEW CLEANOUT.NEW 4" SANITARYSERVICE @ 2% MIN.NEW CLEANOUT.09.28.2021INFRA_RISER ROOM MODS3 4854486048704854486048704862.791+004862.321+254862.26 4864.711+504862.52 4864.771+752+004862.85 4865.30 4864.43 4865.222+254865.14 4865.582+504865.71 4865.762+753+004865.93 4865.81 4866.26 4865.953+253+50PROPOSED GROUNDELEV.EXISTING GROUNDELEV. (APPROX.)PROPOSED GROUNDEXISTING GROUND(APPROX)6.50' MIN COVER STA: 1+59.01 OFF:0.00 8" 45 DEG BEND BLDG 12 FIRE SERVICE STA: 3+10.23 OFF:0.00 8"X8"X6" TEE BLDG 11 WATER SERVICE STA: 3+17.30 OFF:0.00 8"X8"X4" TEE BLDG 11 FIRE SERVICE STA: 3+15.33 OFF:0.00 8"X8"X6" TEE BLDG 12 WATER SERVICE STA: 3+13.22 OFF:0.00 8"X8"X4" TEE STA: 3+28.44 OFF:0.00 8" 90 DEG BEND W/ HYDRANT ASSEMLY. FG @ HYD = 4866.52 REMOVE CAP AND BLOW OFF INSTALL 8" GATE VALVE STA:1+56.85 STORM SEWER CROSSING STA:2+18.32 4.04 18" MIN. CVR INSULATESTORM XING4" XPS RIGIDFOAM OVER 6"OF SAND171.7'8" CL51 DIP - WATER MAINTYPE 'A' TRENCH BACKFILLTYPE 1 PIPE BEDDINGEXISTING 8" DI WATER MAIN.ELEVATION AT CONNECTIONPOINT IS APPROXIMATE.CONTRACTOR TO VERIFY.8" IE = 4858.10 ±STORMDRAINCROSSINGINSULATESTORM XING4" XPS RIGIDFOAM OVER 6"OF SANDSTAFFORD AVE. -APPROXIMATE SECTION.HIGHGROUNDWATER(APPROX)UPUPUPADA UNITADA UNITBUILDING #10APARTMENTTYPE A3,895 SFFFE = 4,865.001340 S. STAFFORD AVEUNITS 1-12BUILDING #11APARTMENTTYPE C8,234 SFFFE = 4,866.001346 S. STAFFORD AVEUNITS 1-24DDD1+00 2+003+003+50SSHYDWS WS WMWMWMWMTBP BP BP BP BP BP BP BP BP BP BP TB P BPBPBPPHBPBPBPBPBPBPPHTBPBP BPBPBPBP WSWSWSFFFFFWV WV WV WVBPBPBPBPBPBPBPBPWV WV coF F F BPBPBPBPBPBPBPBPBPBPPHPHPHPHWVOSWNEW 30.0' PUBLIC UTILITY EASEMENTAB CDABCD1234512345COPYRIGHT GGLO. ALL RIGHTS RESERVED.ORIGINAL SHEET SIZE IS 24"x36"SHEET NO.SHEET TITLEGGLO PROJECT MANAGER:GGLO PRINCIPAL IN CHARGE:PROJECT NO.:OWNER APPROVAL:MARKDATEDESCRIPTION07-31-2023 - RECORD DRAWINGSREVISIONSPROJECT:OWNER:PROJECT ADDRESS:1301 First Avenue, Suite 301Seattle, WA 98101http://www.gglo.comCONNIE ST. GEORGETOM SHELDONCOTTONWOOD SUBDIVISION5500 S COTTONWOOD RDBOZEMAN, MT 59718THE COTTONWOODPROJECTTHE COTTONWOOD PROJECT, LLC3112 LOS FELIZ BOULEVARDLOS ANGELES, CALIFORNIA 90039MARKDATEDESCRIPTION2019111.01®RECORD DRAWINGC310CWATER MAIN PROFILESITE PLAN PACKAGE 'C'1C310CWATER MAIN PROFILEHORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 4'COB STANDARD NOTES:1.ALL CONSTRUCTION WILL CONFORM TO MPWSS, (LATEST) EDITION,AND COB MODIFICATIONS TO MPWSS.2.ANY EXISTING OR NEW VALVES WHICH CONTROL THE COB'S WATERSUPPLY SHALL BE OPERATED BY COB PERSONNEL ONLY.3.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT AMINIMUM OF 24-HOURS PRIOR TO BEGINNING ANY WORK.4.CONTRACTOR SHALL FIELD-VERIFY LINE AND GRADE OF EXISTINGCONNECTIONS PRIOR TO CONSTRUCTION.NORTHNEW FIRE HYDRANTASSEMBLY. SEE5/C401C.SEE 1/C311C FORFIRE LINEPROFILE.NEW8" G.V.NEW4" G.V.NEW 8" 22.5° &11.25° BEND.SEE 2/C311C FORPROFILES.SEE 3/C311C FORPROFILES.NEW8" 90°BEND.NEW 8" WATER MAINNEW6" G.V.NEW6" G.V.NEW4" G.V.