Loading...
HomeMy WebLinkAbout007 C4.0 Civil Utility PlanBLOCK 15 F F F F FFF F F W W W W WWW W W FFF F WWW W W V W V W V ELEC ELECELECELECELECSTDSDS 12''ST 12''ST 12''ST 12''ST 12''ST 12''ST 12''ST12''ST12''ST12''ST12''ST12''ST12''ST12''ST12''ST STSTSTST ST8''ST8'' S T 8''S T 8'' S T 8'' S T W V OSW OSWM UGEUGEUGE UGE UGE 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS UGEP P P UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEP UGEUGEUGEUGEUGEUGEUGEUGEP COMM COMM COMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 2''GAS 4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS4''GAS8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W SSSSSSSS SSSS SSSSHYDW VW V8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 12''SS 12''SS 12''SS 8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS12''SS12''SSW V W VHYDHYD8''SS8''W8''SS8''SSW V W VST ST ST ST ST ST W V W V 1''WOSW 1''WOSWW VW V1''WOSWW VW V STSTSTSTSTSTSTST 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 6''SSOSWW VOSWSSSS 6''SS6''SS6''SS4''SSSSSS 1''W1''W1.5''W1.5''W1.5''W1.5''W1.5''W1.5''W1''W1''W1''W1''W1''W1''W4''SS4''SS4''SS1.5''W1.5''W1.5''W1.5''W4''SS4''SS4''SS4''SS4''SS4''SS1.5''W1.5''W1.5''W1.5''W4''SS4''SS4''SS1.5''W1.5''W1.5''W1.5''WOSW OSWOSW1''W1''W1''W1''W4''SS4''SS4''SS1''W1''W1''W1''W4''SS4''SS4''SSOSWOSW W V8''WOSW 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W 8''W 8''W OSW W VW VUGEOS D 17,900 SF BUILDING #1 41 UNITS 54,059 SQ. FT. BUILDING #2 41 UNITS 54,059 SQ. FT. VICTORIA STREET SOUTH 15THAVENUEWINTERTHURAVENUEEXISTING RETENTION POND 10' PRIVATE UTILITY EASEMENT ROOF LINE (TYP.) ROOF LINE (TYP.) 6" SANITARY SEWER STUB TO BE ABANDONED IN PLACE PER COB WATER AND SEWER DEPT. STANDARDS EXTEND 6" SEWER SERVICE FROM EXISTING 6" PVC SEWER STUB. INSTALL SEWER SERVICE PER COB. STD. DWG. NO. 02730-2 6" SANITARY SEWER STUB TO BE ABANDONED IN PLACE PER COB WATER AND SEWER DEPT. STANDARDS 6" SANITARY SEWER STUB TO BE ABANDONED IN-PLACE PER COB WATER AND SEWER DEPT. STANDARDS CONNECT TO INTERNALLY ROUTED ROOF DRAINS BY OTHERS. DAYLIGHT 8" PVC TO CURB CHASE INSTALLED PER DETAIL 8/C6.1 EXISTING JUNCTION BOX PROPOSED 3-PHASE TRANSFORMER ON 8'X8' CONRETE PAD BY OTHERS EXISTING UNDERGROUND UTILITIES. LOCATION APPROXIMATE. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES PRIOR TO CONSTRUCTION. (TYP.) EXISTING UNDERGROUND UTILITIES. LOCATION APPROXIMATE. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES PRIOR TO CONSTRUCTION. (TYP.) 8" OUTLET PIPE FOR INTERNAL ROOF DRAINS. CONNECT TO 12" STORM SEWER PER COB STD DWG NO. 02720-10 PROPOSED GAS SERVICE AND GAS METER BY OTHERS 9.24'9.59'REMOVE EXISTING CAP AND BLOWOFF. CUT AND REMOVE 8 LF OF WATER MAIN. INSTALL SOLID 8" CAP WITH JOINT RESTRAINTS AT PROPERTY LINE. INSTALL JOINT RESTRAINTS ON ANY JOINTS WITHIN MIN. RESTRAINED LENGTH. LIVE TAP EXISTING 8" WATER MAIN FOR FOUR (4) 4" SERVICES. CONTRACTOR TO COORDINATE TAP WITH COB. CONTRACTOR TO VERIFY DEPTH AND CONDITION OF WATER MAIN AND NOTIFY ENGINEER OF ANY DISCREPANCIES. INSTALL TWO VALVES BOXES IN SIDEWALK AND ONE IN BOULEVARD. INSTALL (2) 4" DIP FIRE SERVICES PER DETAIL 3/C6.0 AND APPROVED FIRE LINE PLANS. INSTALL (2) 4" DOMESTIC WATER SERVICES PER DETAIL 2/C6.0 AND APPROVED WATER SERVICE PLANS. 9.59' 9.24' PROPOSED 3-PHASE TRANSFORMER ON 8'X8' CONRETE PAD BY OTHERS ELECTRICAL SERVICE BY OTHERS ELECTRICAL SERVICE BY OTHERS ELECTRICAL METERS BY OTHERS ELECTRICAL METERS BY OTHERS 10' PRIVATE UTILITY EASEMENT REMOVE EXISTING BLOWOFF. INSTALL SOLID 8" CAP ON WATER MAIN STUB. STORMTECH SC-160LP SYSTEM. SEE C5.0, C6.2, AND C6.3 FOR DETAILS. STORMTECH SC-160LP SYSTEM. SEE C5.0, C6.2, AND C6.3 FOR DETAILS. DRYWELL PER C5.0 AND DETAIL 10/C6.1 EXTEND 6" SEWER SERVICE FROM EXISTING 6" PVC SEWER STUB. INSTALL SEWER SERVICE PER COB. STD. DWG. NO. 02730-2 FIRE RISER ROOM PER ARCHITECTURAL PLANSFIRE RISER ROOM PER ARCHITECTURAL PLANS PROPOSED GAS SERVICE AND GAS METER BY OTHERS ABANDON EXISTING 8" WATER MAIN STUB AT MAIN IN WINTERTHUR AVENUE PER COB WATER AND SEWER DEPT. STANDARDS. BACKFILL WITH SUBBASE COURSE, ROAD MIX, AND ASPHALT TO MATCH EXISTING ROAD SECTION. CONTRACTOR TO REPAIR CURB, SIDEWALK AND BOULEVARD LANDSCAPING TO EXISTING CONDITIONS. TAP EXISTING WATER MAIN STUB FOR 1" IRRIGATION WATER SERVICE. INSTALL IRRIGATION METER PIT PER COB STD DWG NO. 02660-18. C4.0 PROJECT NO: DATE: ENGINEER: REVISIONS DATENO.DESC. SHEET OF 9 22021 August 31, 2023 ELCBLOCK 15 AT BLACKWOOD GROVESBOZEMAN, MONTANABLOCK 15 CIVIL SITE PLANTAOMNNA RN GEO S EF SI NA LROP EINECOTE ETHAN L No. 60593PE ELICNES D8/31/2023 UTILITY PLAN200 40 FEETN 5