Loading...
HomeMy WebLinkAbout025 - P9.0 - PLUMBING DETAILS2 P9.0 11' - 6 1/2"7' - 6"WATER SERVICE FIRE SERVICE FDC GAS SERVICE ELECTRIC SERVICE Level 1 0' -0" LEVEL 1 0' -0" 00 T.O. SLAB 100' -0" SERVICE ANGLE STOP METER/STRAINER ASSEMBLY REDUCED PRESSURE ZONE ASSEMBLY BACKFLOW PREVENTER PRESSURE REDUCING VALVE BUILDING ISOLATION VALVE WATER HEATER2" COLD WATER SERVICE ACE JOB 23BZ5752 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 Client is responsible for notifying architect in writing for any discovered errors or omissions in the plans and specifications during construction of the project. Failure for Client to notify Architect of any known errors or omissions in the plans or specifications, and proceeding with constructing the portion of work shown in the plans or specifications containing known errors or omissions shall be a waiver by Client for any liability of Architect for such known errors or omissions. Client releases Architect for any liability for such portions of work, and Architect shall not be liable for any delay damages, change orders, repair costs, removal or demolition costs, or replacement of any such portions of work. COPYRIGHT 2022 KTGY GROUP INC. These plans and specifications are protected by United States copyright law and may not be used, reproduced, distributed, transmitted, displayed, or modified in any way without the prior written consent of KTGY Group, Inc. or the authorized copyright holder or licensee.Printed : File Path: 07/07/2023 10:05:19 AMAutodesk Docs://5752 - South Range Development Clubhouse/23BZ5752 - Mechanical_R22.rvtBOZEMAN, MTSouth Range CrossingP9.0 PLUMBING DETAILS 07/07/23PRELIMINARY - NOT FOR CONSTRUCTION ktgy Project Number Contact Email Principal Designer Architecture | Branding | Interiors | Planning 3660 Blake St. Suite 500 Denver, CO 80205 ktgy.com 303.825.6400 Ken Hurt khurt@ktgy.com William Ramsey Developer PROVIDENCE DEVELOPMENT CO. 529 E. MAIN STREET BOZEMAN, MT 59772 PROVIDENCEDEVCO.COM 406-551-7939 No. DATE DESCRIPTION 1/4" = 1'-0"1 WATER RISER ROOM ENLARGED PLAN 1/4" = 1'-0"2 WATER RISER SECTION 80 128.5 2" 2" 2" RPZA 60 2" 75 PEAK DEMAND (GPM) PEAK DEMAND (WSFU) SERVICE LINE SIZE METER SIZE BACKFLOW PREVENTER SIZE BACKFLOW PREVENTER TYPE STATIC PRESSURE AT SERVICE PRESSURE REDUCING VALVE SIZE PRESSURE REDUCING VALVE SETPOINT CLUBHOUSE WATER SERVICE SCHEDULE NOTES: 1. CONTRACTOR SHALL VERIFY SITE WATER SUPPLY STATIC PRESSURE AND SHALL NOTE DISCREPENCIES TO THE ENGINEER. 2. SITE CONTRACTOR SHALL PROVIDE WATER SERVICE PIPING AND ACCESSORIES UP TO AND INCLUDING THE SERVICE ANGLE STOP. SITE CONTRACTOR SHALL PROVIDE DISINFECTION, FLUSHING, PRESSURE TESTING, AND BACTERIOLOGICAL TESTING OF THE SERVICE PIPING. PLUMBING CONTRACTOR SHALL PROVIDE PIPING AND ACCESSORIES DOWNSTREAM OF THE SERVICE ANGLE STOP. 3. COORDINATE WITH THE CITY OF BOZEMAN FOR PROCUREMENT AND INSTALLATION OF THE SERVICE WATER METER. 4. SEE PLUMBING SECTIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS. TOTAL 1,150 MBH EQ-### OUTDOOR BBQ 100 MBH EQ-### RANGE 125 MBH EQ-### INDOOR FIRE PLACE 125 MBH POOL EQIUPMENT POOL EQUIPMENT 800 MBH TAG DESCRIPTION ITEM INPUT DEMAND DEMAND UNITS CLUBHOUSE NATURAL GAS FUEL LOAD SUMMARY NOTES: 1. EQUIPMENT INPUT DEMAND AT SITE ELEVATION IS BASED ON "ANSI Z21-13/CSA 4.9 INPUT RATING REQUIREMENTS AT SITE ELEVATION" OR THE PUBLISHED INPUT DEMAND RATING AT SITE ELEVATION BY THE EQUIPMENT MANUFACTURER. 2. SYSTEM DELIVERY PRESSURE SHALL BE 2 PSIG AND SHALL BE REDUED TO 14" W.C. AT EACH PIECE OR GROUP OF EQUIPMENT. COORDINATE WITH THE LOCAL UTILITY PROVIDER. 3. MOST REMOTE FIXTURE IS EQ-### ~#### FEET EQUIVALENT PIPE LENGTH FROM METER. 4. PLUMBING CONTRACTOR SHALL PRIME AND PAINT ALL NATURAL GAS PIPING ON THE BUILDING EXTERIOR TO MATCH THE BUILDING COLOR. COORDINATE WITH GENERAL CONTRACTOR. 5. SEE BUILDING PLUMBING DRAWINGS FOR COORDIANTION AND ADDITIONAL REQUIREMENTS. TOTAL FIXTURE LOAD 128.5 WSFU WATER CLOSET, FLUSHOMETER VALVE UPC TABLE 610.10 4 90 URINAL, FLUSHOMETER VALVE UPC TABLE 610.10 1 20 SINK - LAUNDRY 1.5 0 0 SINK - KITCHEN, DOMESTIC 1.5 2 3 LAVATORY 1 2 2 SERVICE / MOP BASIN 3 1 3 DRINKING FOUNTAIN 0.5 2 1 HOSE BIBB, EACH ADDITIONAL 1 4 4 HOSE BIBB 2.5 1 2.5 DISHWASHER, DOMESTIC 1.5 2 3 CLOTHES WASHER 4 0 0 SHOWER (PER HEAD) 2 0 0 SOAKER TUB 10 0 0 BATHTUB OR COMBINATION BATH/SHOWER 4 0 0 FIXTURE TYPE WATER SUPPLY FIXTURE UNITS / FIX.FIXTURE COUNT WSFU CITY OF BOZEMAN WATER SERVICE CALCULATION - COMMERCIAL NOTES: 1. FIXTURE LOADS IN ACCORDANCE WITH THE CITY OF BOZEMAN COMMERCIAL WATER SERVICE CALCULATION WORKSHEET AND CHAPTER 6 OF THE UNIFORM PLUMBING CODE. 2. DISTRIBUTION PIPE SIZING PROVIDED IN ACCORDANCE WITH CHAPTER 6 OF THE UNIFORM PLUMBING CODE.