HomeMy WebLinkAboutHOA approved combined plan set e (1)ISANTI DOGWOOD (Cornus sericea 'Isanti' )
RUSSIAN SAGE (Perovskia atriplicifolia)
KARL FOERSTER REED GRASS (Calamagrostis acutiflora)
SNOWDRIFT CRABAPPLE TREE (Malus 'Snowdrift')
-2" CALIPER PLANTING
-5 GALLON PLANTING
-48" Height and Spread
-5 GALLON PLANTING
-48" Height
-24"-48" Spread
-1 GALLON PLANTING
-48" Height
-36" Spread
JAPANESE MAPLE TREE (Acer palmatum)
-2" CALIPER PLANTING
SALVIA MARCUS (Sylvestris)
-1 GALLON PLANTING
-24" Height
-16" Spread
BLANKET FLOWER VARIETY
-1 GALLON PLANTING
-16" Height
-16" Spread
GENERAL LANDSCAPE NOTES:
• ALL SOD TO HAVE AUTOMATED U.G. SPRINKLERS.
• ALL PERENIAL PLANTING BEDS TO HAVE AUTOMATED
DRIP IRRIGATION AND / OR SPRAY HEADS.
• ALL PERENIAL BEDS TO HAVE WEED CONTROL MAT AND
WASHED ROCK OR MULCH.
• ALL TREES TO BE 2"-3" CALIPER.
• ALL TREES TO HAVE AUTOMATED BUBBLERS AS
REQUIRED.
• ALL TREES TO BE PLANTED W/IN PLANTING BED / RING.0° 13' 52"75.21'SWLOT 4A
15,327 SQFT
LOT 4B
15,506 SQFT FEN WAYDAVIS LANEUTILITY EASEMENT
12' - 0"P.U.E. / ACCESS12' - 0"P.U.E. / ACCESS12' - 0"P.U.E. / ACCESS
70' - 0"
89° 46' 08"
203.63'
S W 0° 13' 52"75.21'SWSETBACK5' - 0"SETBACK5' - 0"SETBACK
15' - 0"SETBACK5' - 0"SETBACK
15' - 0"
WATER
LINE
89° 46' 08"
203.83'
S E
0° 09' 17"75.22'NE0° 09' 17"77.04'NECONCRETE SIDEWALKCONCRETE SIDEWALKSTREET VISION TRIANGLE
LAWN
LAWN
CONC. WALKWAY
Entry Planting
-4ft Min. Dim
-20sqft Min. Area
entry entry
entry
entryentry
entry entryentryentryentry
entry
12'x12' Open Space
-min/ 10% of Living Space
CONC. WALKWAY
#1 #2 #3 #4 #5
#6#7#8#9#10#11
PERMEABLE PLANTING
AREA BETWEEN
DRIVEWAYS
-XERISCAPING w/
CRUSHED
GRANITE/STONE BEDDING 24' - 2"SNOW STORAGE
BIKE RACKSNOW STORAGESNOW STORAGESNOW STORAGEBIKE RACKASPHALT w/ CONC. CURB AISLES AND DRIVEWAYS
PERENNIAL PLANTING
BEDS w/ METAL EDGING
LAWN
LAWN
LAWN
12' - 0"12' - 0"SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
As indicated
l2.1
Landscape Plan
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
PLANTING LEGEND
1" = 10'-0"1
Landscape Plan
OPEN SPACE REQUIREMENT CALCULATION
-10% OF LIVING SPACE TO BE ALLOCATED TO EXTERIOR
OPEN SPACE PER UNIT.
-1,247 SQFT PER UNIT x 10% = 125 SQFT PER UNIT
MEET MIN REQUIREMENT OF 12FT X 12FT = 144 SQFT.
REV. DATE REMARKS
• R310.2.1 : MINIMUM OPENING AREA REQUIRING THAT NET OPENING NOT LESS THAN 5.7 SQ. FT., MINIMUM OPENING HEIGHT
NOT LESS THAN 24”, MINIMUM WIDTH NOT LESS 20”. THE CLEAR OPENING HEIGHT (SILL) FROM FINISHED FLOOR NOT MORE
THAN 44”.
• R311.2 : EGRESS DOOR REQUIRED TO BE LABEL ON DRAWINGS. PLEASE ADD NOTATION. CLEAR OPENING WIDTH SHALL NOT
BE LESS THAN 32”AND SHALL NOT BE LESS THAN 78”IN CLEAR HEIGHT.
• R311.3 : LANDING SHALL BE REQUIRED ON BOTH SIDE OF THE EGRESS DOOR, WIDTH SHALL BE NO LESS THAN THE DOOR
SERVED, AND MEASURING NO LESS THAN 36”IN THE DIRECTION OF TRAVEL.
• OPENINGS BETWEEN GARAGE AND DWELLING SHALL HAVE MIN. 20 MINUTE RATING AND EQUIPPED WITH SELF-CLOSING
DEVICE.
• R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS
DOOR SHALL BE NOT MORE THAN 11/2 INCHES (38 MM) LOWER THAN THE TOP OF THE THRESHOLD.
1. EXCEPTION: THE LANDING OR FLOOR ON THE EXTERIOR SIDE SHALL BE NOT MORE THAN 73/4 INCHES (196 MM)
BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR.
2. WHERE EXTERIOR LANDINGS OR FLOORS SERVING THE REQUIRED EGRESS DOOR ARE NOT AT GRADE, THEY SHALL
BE PROVIDED WITH ACCESS TO GRADE BY MEANS OF A RAMP IN ACCORDANCE WITH SECTION R311.8 OR A STAIRWAY
IN ACCORDANCE WITH SECTION R311.7.
R311.7.1 WIDTH
STAIRWAYS SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL
HEIGHT AND BELOW THE REQUIRED HEADROOM
HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 41/2 INCHES (114 MM) ON EITHER SIDE OF THE STAIRWAY AND THE CLEAR
WIDTH OF THE STAIRWAY AT AND BELOW THE
HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL BE NOT LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS
INSTALLED ON ONE SIDE AND 27 INCHES (698
MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES.
EXCEPTION: THE WIDTH OF SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH SECTION R311.7.10.1.
R311.7.2 HEADROOM
THE HEADROOM IN STAIRWAYS SHALL BE NOT LESS THAN 6 FEET 8 INCHES (2032 MM) MEASURED VERTICALLY FROM THE SLOPED
LINE ADJOINING THE TREAD NOSING OR FROM
THE FLOOR SURFACE OF THE LANDING OR PLATFORM ON THAT PORTION OF THE STAIRWAY.
EXCEPTIONS:
1. WHERE THE NOSINGS OF TREADS AT THE SIDE OF A FLIGHT EXTEND UNDER THE EDGE OF A FLOOR OPENING THROUGH WHICH
THE STAIR PASSES, THE FLOOR
OPENING SHALL BE ALLOWED TO PROJECT HORIZONTALLY INTO THE REQUIRED HEADROOM NOT MORE THAN 43/4 INCHES (121 MM).
2. THE HEADROOM FOR SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH SECTION R311.7.10.1.
R311.7.3 VERTICAL RISE
A FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL RISE LARGER THAN 151 INCHES BETWEEN FLOOR LEVELS OR LANDINGS.
R311.7.5.2 TREADS
THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY
BETWEEN THE VERTICAL PLANES OF THE FOREMOST
PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN
ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE
SMALLEST BY MORE THAN 3/8 INCH (9.5 MM).
R311.7.5.2.1 WINDER TREADS
WINDER TREADS SHALL HAVE A TREAD DEPTH OF NOT LESS THAN 10 INCHES (254 MM) MEASURED BETWEEN THE VERTICAL PLANES
OF THE FOREMOST PROJECTION OF
ADJACENT TREADS AT THE INTERSECTIONS WITH THE WALKLINE. WINDER TREADS SHALL HAVE A TREAD DEPTH OF NOT LESS THAN
6 INCHES (152 MM) AT ANY POINT WITHIN
THE CLEAR WIDTH OF THE STAIR. WITHIN ANY FLIGHT OF STAIRS, THE LARGEST WINDER TREAD DEPTH AT THE WALKLINE SHALL
NOT EXCEED THE SMALLEST WINDER TREAD BY
MORE THAN 3/8 INCH (9.5 MM). CONSISTENTLY SHAPED WINDERS AT THE WALKLINE SHALL BE ALLOWED WITHIN THE SAME FLIGHT
OF STAIRS AS RECTANGULAR TREADS AND DO
NOT HAVE TO BE WITHIN 3/8 INCH (9.5 MM) OF THE RECTANGULAR TREAD DEPTH.
EXCEPTION: THE TREAD DEPTH AT SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH SECTION R311.7.10.1.
R311.7.8 HANDRAILS
HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR
MORE RISERS.
R311.7.8.1 HEIGHT
HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF
RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES
(864 MM) AND NOT MORE THAN 38 INCHES (965 MM).
EXCEPTIONS:
1. THE USE OF A VOLUTE, TURNOUT OR STARTING EASING SHALL BE ALLOWED OVER THE LOWEST TREAD.
2. WHERE HANDRAIL FITTINGS OR BENDINGS ARE USED TO PROVIDE CONTINUOUS TRANSITION BETWEEN FLIGHTS, TRANSITIONS AT
WINDER TREADS, THE TRANSITION
FROM HANDRAIL TO GUARD, OR USED AT THE START OF A FLIGHT, THE HANDRAIL HEIGHT AT THE FITTINGS OR BENDINGS SHALL BE
PERMITTED TO EXCEED 38
INCHES (956 MM).
R311.7.8.2 CONTINUITY
HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE
TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE
THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY
TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL
HAVE A SPACE OF NOT LESS THAN 11/2 INCHES (38 MM) BETWEEN THE WALL AND THE HANDRAILS.
EXCEPTIONS:
1. HANDRAILS SHALL BE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AT THE TURN.
2. THE USE OF A VOLUTE, TURNOUT, STARTING EASING OR STARTING NEWEL SHALL BE ALLOWED OVER THE LOWEST TREAD.
R311.7.8.3 GRIP-SIZE
REQUIRED HANDRAILS SHALL BE OF ONE OF THE FOLLOWING TYPES OR PROVIDE EQUIVALENT GRASPABILITY.
1. TYPE I. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 11/4 INCHES (32
MM) AND NOT GREATER THAN 2
INCHES (51 MM). IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF NOT LESS THAN 4 INCHES (102 MM)
AND NOT GREATER THAN
61/4 INCHES (160 MM) WITH A CROSS SECTION OF DIMENSION OF NOT MORE THAN 21/4 INCHES (57 MM). EDGES SHALL HAVE A
RADIUS OF NOT LESS THAN
0.01 INCH (0.25 MM).
2. TYPE II. HANDRAILS WITH A PERIMETER GREATER THAN 61/4 INCHES (160 MM) SHALL HAVE A GRASPABLE FINGER RECESS AREA
ON BOTH SIDES OF THE
PROFILE. THE FINGER RECESS SHALL BEGIN WITHIN A DISTANCE OF 3/4 INCH (19 MM) MEASURED VERTICALLY FROM THE TALLEST
PORTION OF THE PROFILE AND
ACHIEVE A DEPTH OF NOT LESS THAN 5/16 INCH (8 MM) WITHIN 7/8 INCH (22 MM) BELOW THE WIDEST PORTION OF THE PROFILE. THIS
REQUIRED DEPTH SHALL
CONTINUE FOR NOT LESS THAN 3/8 INCH (10 MM) TO A LEVEL THAT IS NOT LESS THAN 13/4 INCHES (45 MM) BELOW THE TALLEST
PORTION OF THE PROFILE. THE
WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE NOT LESS THAN 11/4 INCHES (32 MM) AND NOT MORE THAN 23/4 INCHES (70
MM). EDGES SHALL
HAVE A RADIUS OF NOT LESS THAN 0.01 INCH (0.25 MM).
R311.7.8.4 EXTERIOR PLASTIC COMPOSITE HANDRAILS
PLASTIC COMPOSITE EXTERIOR HANDRAILS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION R507.3.
R317.1 LOCATION REQUIRED
PROTECTION OF WOOD AND WOOD-BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS BY THE USE
OFN ATURALLY DURABLE WOOD OR WOOD THAT
IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE.
PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA
U1.
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHEN
CLOSER THAN 12 INCHES (305
MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE PERIPHERY OF THE BUILDING
FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES
(203 MM) FROM THE EXPOSED
GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED FROM
SUCH SLAB BY AN IMPERVIOUS
MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH
(12.7 MM) ON TOPS, SIDES AND
ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152
MM) FROM THE GROUND OR
LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL
SURFACES EXPOSED TO THE
WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER,
SUCH AS CONCRETE OR MASONRY
SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY WALLS
OR CONCRETE WALLS BELOW
GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL AND THE FURRING STRIPS OR FRAMING
MEMBERS.
R317.1.1 FIELD TREATMENT
FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE
WITH AWPA M4.
R317.1.2 GROUND CONTACT
ALL WOOD IN CONTACT WITH THE GROUND, EMBEDDED IN CONCRETE IN DIRECT CONTACT WITH THE GROUND OR EMBEDDED IN
CONCRETE EXPOSED TO THE WEATHER THAT
SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL BE APPROVED PRESSURE-PRESERVATIVE-TREATED
WOOD SUITABLE FOR GROUND CONTACT
USE, EXCEPT THAT UNTREATED WOOD USED ENTIRELY BELOW GROUNDWATER LEVEL OR CONTINUOUSLY SUBMERGED IN FRESH
WATER SHALL NOT BE REQUIRED TO BE
PRESSURE-PRESERVATIVE TREATED.
R317.1.3 GEOGRAPHICAL AREAS
IN GEOGRAPHICAL AREAS WHERE EXPERIENCE HAS DEMONSTRATED A SPECIFIC NEED, APPROVED NATURALLY DURABLE OR
PRESSURE-PRESERVATIVE-TREATED WOOD SHALL
BE USED FOR THOSE PORTIONS OF WOOD MEMBERS THAT FORM THE STRUCTURAL SUPPORTS OF BUILDINGS, BALCONIES, PORCHES
OR SIMILAR PERMANENT BUILDING
APPURTENANCES WHEN THOSE MEMBERS ARE EXPOSED TO THE WEATHER WITHOUT ADEQUATE PROTECTION FROM A ROOF, EAVE,
OVERHANG OR OTHER COVERING THAT
WOULD PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE OR AT JOINTS BETWEEN MEMBERS. DEPENDING ON LOCAL
EXPERIENCE, SUCH MEMBERS MAY
INCLUDE:
1. HORIZONTAL MEMBERS SUCH AS GIRDERS, JOISTS AND DECKING.
2. VERTICAL MEMBERS SUCH AS POSTS, POLES AND COLUMNS.
3. BOTH HORIZONTAL AND VERTICAL MEMBERS.
R317.1.4 WOOD COLUMNS
WOOD COLUMNS SHALL BE APPROVED WOOD OF NATURAL DECAY RESISTANCE OR APPROVED PRESSURE-PRESERVATIVE-TREATED
WOOD.
EXCEPTIONS:
1. COLUMNS EXPOSED TO THE WEATHER OR IN BASEMENTS WHERE SUPPORTED BY CONCRETE PIERS OR METAL PEDESTALS
PROJECTING 1 INCH (25 MM)
ABOVE A CONCRETE FLOOR OR 6 INCHES (152 MM) ABOVE EXPOSED EARTH AND THE EARTH IS COVERED BY AN APPROVED IMPERVIOUS
MOISTURE
BARRIER.
2. COLUMNS IN ENCLOSED CRAWL SPACES OR UNEXCAVATED AREAS LOCATED WITHIN THE PERIPHERY OF THE BUILDING WHEN
SUPPORTED BY A CONCRETE
PIER OR METAL PEDESTAL AT A HEIGHT MORE THAN 8 INCHES (203 MM) FROM EXPOSED EARTH AND THE EARTH IS COVERED BY AN
IMPERVIOUS
MOISTURE BARRIER.
3. DECK POSTS SUPPORTED BY CONCRETE PIERS OR METAL PEDESTALS PROJECTING NOT LESS THAN 1 INCH (25 MM) ABOVE A
CONCRETE FLOOR OR 6 INCHES
(152 MM) ABOVE EXPOSED EARTH.
R317.1.5 EXPOSED GLUED-LAMINATED TIMBERS
THE PORTIONS OF GLUED-LAMINATED TIMBERS THAT FORM THE STRUCTURAL SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND
ARE EXPOSED TO WEATHER AND NOT
PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BE PRESSURE TREATED WITH PRESERVATIVE, OR BE
MANUFACTURED FROM NATURALLY DURABLE OR
PRESERVATIVE-TREATED WOOD.
R317.1.1 FIELD TREATMENT
FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE
WITH AWPA M4.
R317.1.2 GROUND CONTACT
ALL WOOD IN CONTACT WITH THE GROUND, EMBEDDED IN CONCRETE IN DIRECT CONTACT WITH THE GROUND OR EMBEDDED IN
CONCRETE EXPOSED TO THE WEATHER THAT
SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL BE APPROVED PRESSURE-PRESERVATIVE-TREATED
WOOD SUITABLE FOR GROUND CONTACT USE,
EXCEPT THAT UNTREATED WOOD USED ENTIRELY BELOW GROUNDWATER LEVEL OR CONTINUOUSLY SUBMERGED IN FRESH WATER
SHALL NOT BE REQUIRED TO BE PRESSUREPRESERVATIVE
TREATED.
R317.3 FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED AND
FIRE-RETARDANT-TREATED WOOD
FASTENERS, INCLUDING NUTS AND WASHERS, AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED WOOD AND FIRE-
RETARDANT-TREATED WOOD SHALL BE IN ACCORDANCE
WITH THIS SECTION. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. STAINLESS
STEEL DRIVEN FASTENERS SHALL BE IN
ACCORDANCE WITH THE MATERIAL REQUIREMENTS OF ASTM F1667.
R317.3.1 FASTENERS FOR PRESERVATIVE-TREATED WOOD
FASTENERS, INCLUDING NUTS AND WASHERS, FOR PRESERVATIVE-TREATED WOOD SHALL BE OF HOT-DIPPED, ZINC-COATED
GALVANIZED STEEL, STAINLESS STEEL, SILICON
BRONZE OR COPPER. COATING TYPES AND WEIGHTS FOR CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE IN
ACCORDANCE WITH THE CONNECTOR
MANUFACTURER'S RECOMMENDATIONS. IN THE ABSENCE OF MANUFACTURER'S RECOMMENDATIONS, A MINIMUM OF ASTM A 653 TYPE
G185 ZINC-COATED GALVANIZED
STEEL, OR EQUIVALENT, SHALL BE USED.
EXCEPTIONS:
1. 1/2-INCH-DIAMETER (12.7 MM) OR GREATER STEEL BOLTS.
2. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC-COATED STEEL
WITH COATING WEIGHTS
IN ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM.
3. PLAIN CARBON STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT
SHALL BE PERMITTED.
R317.3.2 FASTENINGS FOR WOOD FOUNDATIONS
FASTENINGS, INCLUDING NUTS AND WASHERS, FOR WOOD FOUNDATIONS SHALL BE AS REQUIRED IN AF&PA; PWF.
R317.3.3 FASTENERS FOR FIRE-RETARDANT-TREATED WOOD USED IN EXTERIOR APPLICATIONS OR WET OR DAMP LOCATIONS
FASTENERS, INCLUDING NUTS AND WASHERS, FOR FIRE-RETARDANT-TREATED WOOD USED IN EXTERIOR APPLICATIONS OR WET OR
DAMP LOCATIONS SHALL BE OF HOT-DIPPED,
ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS
SHALL BE PERMITTED TO BE OF
MECHANICALLY DEPOSITED ZINC-COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM.
R317.3.4 FASTENERS FOR FIRE-RETARDANT-TREATED WOOD USED IN INTERIOR APPLICATIONS
FASTENERS, INCLUDING NUTS AND WASHERS, FOR FIRE-RETARDANT-TREATED WOOD USED IN INTERIOR LOCATIONS SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS. IN THE ABSENCE OF THE MANUFACTURER'S RECOMMENDATIONS, SECTION R317.3.3 SHALL APPLY.
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
ROSET & ASSOCIATES
PoBox 10234
BOZEMAN, MT 59719
BUILDER
406.581.5634
eric@rosetassociates.com
ERIC ROSET
12" = 1'-0"
a0.1
Schedules / Notes
CATTAIL DUPLEXES
Author
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
12" = 1'-0"1
EGRESS NOTES
12" = 1'-0"
2 STAIR NOTES
12" = 1'-0"
3 PROTECTION OF WOOD PRODUCTS NOTES
REV. DATE REMARKS
R302.5 DWELLING-GARAGE OPENING AND PENETRATION PROTECTION
• OPENINGS AND PENETRATIONS THROUGH THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE IN ACCORDANCE WITH SECTIONS
R302.5.1 THROUGH 302.5.3.
• R302.5.1 OPENING PROTECTION = OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER
OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES (35 MM) IN THICKNESS, SOLID OR
HONEYCOMB-CORE STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR 20-MINUTE FIRE-RATED DOORS, EQUIPPED WITH A SELF-CLOSING DEVICE OR
AUTOMATIC-CLOSING DEVICE. .
• R302.5.2 DUCT PENETRATION = DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL
BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE OPENINGS INTO THE GARAGE.
• R302.5.3 OTHER PENETRATIONS = PENETRATIONS THROUGH THE SEPARATION REQUIRED IN SECTION R302.6 SHALL BE PROTECTED AS REQUIRED BY SECTION
R302.11, ITEM 4.
R302.4.2 MEMBRANE PENETRATIONS
• MEMBRANE PENETRATIONS SHALL COMPLY WITH SECTION R302.4.1. WHERE WALLS ARE REQUIRED TO HAVE A FIRE-RESISTANCE RATING, RECESSED FIXTURES
SHALL BE INSTALLED SO THAT THE REQUIRED FIRE-RESISTANCE RATING WILL NOT BE REDUCED.
EXCEPTIONS:
1. MEMBRANE PENETRATIONS OF NOT MORE THAN 2-HOUR FIRE-RESISTANCE-RATED WALLS AND PARTITIONS BY STEEL ELECTRICAL BOXES THAT DO NOT EXCEED
16 SQUARE INCHES (0.0103 M2) IN AREA PROVIDED THAT THE AGGREGATE AREA OF THE OPENINGS THROUGH THE MEMBRANE DOES NOT EXCEED 100
SQUARE INCHES (0.0645 M2) IN ANY 100 SQUARE FEET (9.29 M2) OF WALL AREA. THE ANNULAR SPACE BETWEEN THE WALL MEMBRANE AND THE BOX SHALL
NOT EXCEED 1/8 INCH (3.1 MM). SUCH BOXES ON OPPOSITE SIDES OF THE WALL SHALL BE SEPARATED BY ONE OF THE FOLLOWING:
1.1. BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES (610 MM) WHERE THE WALL OR PARTITION IS CONSTRUCTED WITH INDIVIDUAL
NONCOMMUNICATING STUD CAVITIES.
1.2. BY A HORIZONTAL DISTANCE OF NOT LESS THAN THE DEPTH OF THE WALL CAVITY WHERE THE WALL CAVITY IS FILLED WITH CELLULOSE LOOSE-FILL,
ROCKWOOL OR SLAG MINERAL WOOL INSULATION.
1.3. BY SOLID FIREBLOCKING IN ACCORDANCE WITH SECTION R302.11.
1.4. BY PROTECTING BOTH BOXES WITH LISTED PUTTY PADS.
1.5. BY OTHER LISTED MATERIALS AND METHODS.
2. MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIALS PROVIDED THAT THE BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCERATED
ASSEMBLIES AND ARE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED IN THE LISTING. THE ANNULAR SPACE BETWEEN THE WALL
MEMBRANE AND THE BOX SHALL NOT EXCEED 1/8 INCH (3.1 MM) UNLESS LISTED OTHERWISE. SUCH BOXES ON OPPOSITE SIDES OF THE WALL SHALL BE
SEPARATED BY ONE OF THE FOLLOWING:
2.1. BY THE HORIZONTAL DISTANCE SPECIFIED IN THE LISTING OF THE ELECTRICAL BOXES.
2.2. BY SOLID FIREBLOCKING IN ACCORDANCE WITH SECTION R302.11.
2.3. BY PROTECTING BOTH BOXES WITH LISTED PUTTY PADS.
2.4. BY OTHER LISTED MATERIALS AND METHODS.
3. THE ANNULAR SPACE CREATED BY THE PENETRATION OF A FIRE SPRINKLER PROVIDED THAT IT IS COVERED BY A METAL ESCUTCHEON PLATE.
4. CEILING MEMBRANE PENETRATIONS BY LISTED LUMINAIRES OR BY LUMINAIRES PROTECTED WITH LOSTED MATERIALS THAT HAVE BEEN TESTED FOR USE IN FIRE-
RESISTANCE RELATED ASSEMBLIES AND ARE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED IN THE LISTING.
R302.4.1 THROUGH PENETRATIONS
THROUGH PENETRATIONS OF FIRE-RESISTANCE-RATED WALL OR FLOOR ASSEMBLIES SHALL COMPLY WITH SECTION R302.4.1.1 OR R302.4.1.2.
EXCEPTION: WHERE THE PENETRATING ITEMS ARE STEEL, FERROUS OR COPPER PIPES, TUBES OR CONDUITS, THE ANNULAR SPACE SHALL BE PROTECTED AS FOLLOWS:
1. IN CONCRETE OR MASONRY WALL OR FLOOR ASSEMBLIES, CONCRETE, GROUT OR MORTAR SHALL BE PERMITTED WHERE INSTALLED TO THE FULL THICKNESS OF
THE WALL OR FLOOR ASSEMBLY OR THE THICKNESS REQUIRED TO MAINTAIN THE FIRE-RESISTANCE RATING, PROVIDED THAT BOTH OF THE FOLLOWING ARE
COMPLIED WITH:
1.1. THE NOMINAL DIAMETER OF THE PENETRATING ITEM IS NOT MORE THAN 6 INCHES (152 MM).
1.2. THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE INCHES (92 900 MM2).
2. THE MATERIAL USED TO FILL THE ANNULAR SPACE SHALL PREVENT THE PASSAGE OF FLAME AND HOT GASES SUFFICIENT TO IGNITE COTTONW ASTE WHERE
SUBJECTED TO ASTM E 119 OR UL 263 TIME TEMPERATURE FIRE CONDITIONS UNDER A POSITIVE PRESSURE DIFFERENTIAL OF NOT LESS THAN 0.01 INCH OF
WATER (3 PA) AT THE LOCATION OF THE PENETRATION FOR THE TIME PERIOD EQUIVALENT TO THE FIRE-RESISTANCE RATING OF THE CONSTRUCTION PENETRATED.
R302.4.1.1 FIRE-RESISTANCE-RATED ASSEMBLY
PENETRATIONS SHALL BE INSTALLED AS TESTED IN THE APPROVED FIRE-RESISTANCE-RATED ASSEMBLY.
R302.4.1.2 PENETRATION FIRESTOP SYSTEM
PENETRATIONS SHALL BE PROTECTED BY AN APPROVED PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479, WITH A
POSITIVE PRESSURE DIFFERENTIAL OF NOT LESS THAN 0.01 INCH OF WATER (3 PA) AND SHALL HAVE AN F RATING OF NOT LESS THAN THE REQUIRED FIRE-RESISTANCE
RATING OF
THE WALL OR FLOOR-CEILING ASSEMBLY PENETRATED.
R302.7 UNDER-STAIR PROTECTION
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS THAT IS ACCESSED BY A DOOR OR ACCESS PANEL SHALL HAVE WALLS, UNDER-
STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2-INCH (12.7 MM)
GYPSUM BOARD.
R302.9 Flame Spread Index and Smoke-Developed Index for Wall and Ceiling
Finishes
Flame spread and smoke developed indexes for wall and ceiling finishes shall be in accordance with Sections R302.9.1 through R302.9.4.
R302.9.1 Flame Spread Index
Wall and ceiling finishes shall have a flame spread index of not greater than 200.
Exception: Flame spread index requirements for finishes shall not apply to trim defined as picture molds, chair rails, baseboards and handrails; to
doors and windows or their frames; or to materials that are less than 1/28 inch (0.91 mm) in thickness cemented to the surface of walls or ceilings if
these materials exhibit flame spread index values not greater than those of paper of this thickness cemented to a noncombustible backing.
R302.9.2 Smoke-Developed Index
Wall and ceiling finishes shall have a smoke-developed index of not greater than 450.
R302.9.3 Testing
Tests shall be made in accordance with ASTM E 84 or UL 723.
R302.9.4 Alternative Test Method
As an alternative to having a flame spread index of not greater than 200 and a smoke-developed index of not greater than 450 where tested in
accordance with ASTM E 84 or UL 723, wall and ceiling finishes shall be permitted to be tested in accordance with NFPA 286. Materials tested in
accordance with NFPA 286 shall meet the following criteria:
The interior finish shall comply with the following:
1. During the 40 kW exposure, flames shall not spread to the ceiling.
2. The flame shall not spread to the outer extremity of the sample on any wall or ceiling.
3. Flashover, as defined in NFPA 286, shall not occur.
4. The peak heat release rate throughout the test shall not exceed 800 kW.
5. The total smoke released throughout the test shall not exceed 1,000 m2.
R302.11 Fireblocking
In combustible construction, fireblocking shall be provided to cut off both vertical and horizontal concealed draft openings and to form an effective fire
barrier between stories, and between a top story and the roof space.
Fireblocking shall be provided in wood-framed construction in the following locations:
1. In concealed spaces of stud walls and partitions, including furred spaces and parallel rows of studs or staggered studs, as follows:
1.1. Vertically at the ceiling and floor levels.
1.2. Horizontally at intervals not exceeding 10 feet (3048 mm).
2. At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings.
3. In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces under stairs shall comply with Section
R302.7.
4. At openings around vents, pipes, ducts, cables and wires at ceiling and floor level, with ana pproved material to resist the free passage of
flame and products of combustion. The material filling this annular space shall not be required to meet the ASTM E 136 requirements.
5. For the fireblocking of chimneys and fireplaces, see Section R1003.19.
6. Fireblocking of cornices of a two-family dwelling is required at the line of dwelling unit separation.
R302.11.1 Fireblocking Materials
Except as provided in Section R302.11, Item 4, fireblocking shall consist of the following materials.
1. Two-inch (51 mm) nominal lumber.
2. Two thicknesses of 1-inch (25.4 mm) nominal lumber with broken lap joints.
3. One thickness of 23/32-inch (18.3 mm) wood structural panels with joints backed by 23/32-inch (18.3 mm) wood structural panels.
4. One thickness of 3/4-inch (19.1 mm) particleboard with joints backed by 3/4-inch (19.1 mm) particleboard.
5. One-half-inch (12.7 mm) gypsum board.
6. One-quarter-inch (6.4 mm) cement-based millboard.
7. Batts or blankets of mineral wool or glass fiber or other approved materials installed in such a manner as to be securely retained in
place.
8. Cellulose insulation installed as tested in accordance with ASTM E119 or UL 263, for the specific application.
R302.11.1.1 Batts or Blankets of Mineral or Glass Fiber
Batts or blankets of mineral or glass fiber or other approved nonrigid materials shall be permitted for compliance with the 10-foot (3048 mm)
horizontal fireblocking in walls constructed using parallel rows of studs or staggered studs.
R302.11.1.2 Unfaced Fiberglass
Unfaced fiberglass batt insulation used as fireblocking shall fill the entire cross section of the wall cavity to a height of not less than 16 inches (406
mm) measured vertically. Where piping, conduit or similar obstructions are encountered, the insulation shall be packed tightly around the
obstruction.
R302.11.1.3 Loose-Fill Insulation Material
Loose-fill insulation material shall not be used as a fireblock unless specifically tested in the form and manner intended for use to demonstrate its
ability to remain in place and to retard the spread of fire and hot gases.
R302.11.2 Fireblocking Integrity
The integrity of fireblocks shall be maintained.
R302.11.1 Fireblocking Materials
Except as provided in Section R302.11, Item 4, fireblocking shall consist of the following materials.
1. Two-inch (51 mm) nominal lumber.
2. Two thicknesses of 1-inch (25.4 mm) nominal lumber with broken lap joints.
3. One thickness of 23/32-inch (18.3 mm) wood structural panels with joints backed by 23/32-inch (18.3 mm) wood structural panels.
4. One thickness of 3/4-inch (19.1 mm) particleboard with joints backed by 3/4-inch (19.1 mm) particleboard.
5. One-half-inch (12.7 mm) gypsum board.
6. One-quarter-inch (6.4 mm) cement-based millboard.
7. Batts or blankets of mineral wool or glass fiber or other approved materials installed in such a manner as to be securely retained in place.
8. Cellulose insulation installed as tested in accordance with ASTM E119 or UL 263, for the specific application.
R302.11.1.1 Batts or Blankets of Mineral or Glass Fiber
Batts or blankets of mineral or glass fiber or other approved nonrigid materials shall be permitted for compliance with the 10-foot (3048 mm)
horizontal fireblocking in walls constructed using parallel rows of studs or staggered studs.
R302.11.1.2 Unfaced Fiberglass
Unfaced fiberglass batt insulation used as fireblocking shall fill the entire cross section of the wall cavity to a height of not less than 16 inches (406
mm) measured vertically. Where piping, conduit or similar obstructions are encountered, the insulation shall be packed tightly around the
obstruction.
R302.11.1.3 Loose-Fill Insulation Material
Loose-fill insulation material shall not be used as a fireblock unless specifically tested in the form and manner intended for use to demonstrate its
ability to remain in place and to retard the spread of fire and hot gases.
R302.12 Draftstopping
In combustible construction where there is usable space both above and below the concealed space of a floor-ceiling assembly, draftstops shall be
installed so that the area of the concealed space does not exceed 1,000 square feet (92.9 m2). Draftstopping shall divide the concealed space into
approximately equal areas. Where the assembly is enclosed by a floor membrane above and a ceiling membrane below, draftstopping shall be provided
in floor-ceiling assemblies under the following circumstances:
1. Ceiling is suspended under the floor framing.
2. Floor framing is constructed of truss-type open-web or perforated members.
R302.12.1 Materials
Draftstopping materials shall be not less than 1/2-inch (12.7 mm) gypsum board, 3/8-inch (9.5 mm) wood structural panels or other approved materials
adequately supported. Draftstopping shall be installed parallel to the floor framing members unless otherwise approved by the building official. The
integrity of the draftstops shall be maintained.
R302.3 TWO-FAMILY DWELLINGS
DWELLING UNITS IN TWO-FAMILY DWELLINGS SHALL BE SEPARATED FROM EACH OTHER BY WALL AND FLOOR ASSEMBLIES HAVING NOT LESS THAN A 1-HOUR FIRE-RESISTANCE
RATING WHERE TESTED IN ACCORDANCE WITH ASTM E 119 OR UL 263. FIRE-RESISTANCE-RATED FLOOR/CEILING AND WALL ASSEMBLIES SHALL EXTEND TO AND BE TIGHT AGAINST
THE EXTERIOR WALL, AND WALL ASSEMBLIES SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING.
EXCEPTIONS:
1. A FIRE-RESISTANCE RATING OF 1/2 HOUR SHALL BE PERMITTED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
ACCORDANCE WITH NFPA 13.
2. WALL ASSEMBLIES NEED NOT EXTEND THROUGH ATTIC SPACES WHERE THE CEILING IS PROTECTED BY NOT LESS THAN 5/8-INCH (15.9 MM) TYPE X GYPSUM
BOARD, AN ATTIC DRAFT STOP CONSTRUCTED AS SPECIFIED IN SECTION R302.12.1 IS PROVIDED ABOVE AND ALONG THE WALL ASSEMBLY SEPARATING THE
DWELLINGS AND THE STRUCTURAL FRAMING SUPPORTING THE CEILING IS PROTECTED BY NOT LESS THAN 1/2-INCH (12.7 MM) GYPSUM BOARD OR EQUIVALENT.
R302.3.1 SUPPORTING CONSTRUCTION
WHEN FLOOR ASSEMBLIES ARE REQUIRED TO BE FIRE-RESISTANCE RATED BY SECTION R302.3, THE SUPPORTING CONSTRUCTION OF SUCH ASSEMBLIES SHALL HAVE AN EQUAL
OR GREATER FIRE-RESISTANCE RATING.
EXCEPTION: THE SUPPORTING CONSTRUCTION IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED WHERE AUTOMATIC FIRE SPRINKLERS ARE INSTALLED IN ACCORDANCE WITH
APPENDIX Q IN BOTH DWELLING UNITS.
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
ROSET & ASSOCIATES
PoBox 10234
BOZEMAN, MT 59719
BUILDER
406.581.5634
eric@rosetassociates.com
ERIC ROSET
12" = 1'-0"
a0.2
Fire Safety Notes
CATTAIL DUPLEXES
Author
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
12" = 1'-0"
1 GENERAL FIRE SEPERATION NOTES
12" = 1'-0"4 FLAME SPREAD NOTES
12" = 1'-0"
3 FIREBLOCKING & DRAFTSTOPPING NOTES
2 TW0-DWELLING FIRE SEPERATION NOTES
REV. DATE REMARKS
0° 13' 52"75.21'SWFEN WAYP.U.E. / ACCESS12' - 0"P.U.E. / ACCESS12' - 0"89° 46' 08"
203.63'
S W 0° 13' 52"75.21'SWSETBACK5' - 0"SETBACK5' - 0"SETBACK
15' - 0"
SETBACK
15' - 0"SEWER0° 09' 17"75.22'NE0° 09' 17"77.04'NEEXISTING N.W.E.
TRANSFORMER BOX / DATA
PEDESTAL / N.G. SETBACK5' - 0"SETBACK5' - 0"1hr Rated Entry Awning Construction
@ THIS UNIT ONLY
0"1hr FIRE PARTITION
BETWEEN R-3 TWO
FAMILY DWELLINGS,
TYPICAL
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
PROVIDE 2HR FIRE BARRIER
BETWEEN 2ND AND 3RD UNIT.
-NON SPRINKLERED
1hr FIRE PARTITION
BETWEEN R-3 TWO FAMILY
DWELLINGS, TYPICAL
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
UTILITY EASEMENT
12' - 0"
EXISTING N.W.E.
TRANSFORMER BOX FOR
NEIGHBORING PROPERTY.
1hr FIRE PARTITION
BETWEEN R-3 TWO
FAMILY DWELLINGS,
TYPICAL 1hr Rated Entry Awning Construction
@ THIS UNIT ONLY
1hr Rated Entry Awning Construction
@ THIS UNIT ONLY
PROVIDE 2HR FIRE BARRIER
BETWEEN 2ND AND 3RD UNIT.
-NON SPRINKLERED
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
1/8" = 1'-0"
a0.3
Fire Separation Diagram
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
0 2 10 181/8" = 1'-0"
1 Fire Separation Distance - Diagram
REV. DATE REMARKS
-
---
A B
2
1
AB
2
1
A B
2
1
20' - 0"11' - 0"
1 CAR GARAGE
9' - 0"18' - 0"PARKING SPOT9' - 0"18' - 0"PARKING SPOTFRONTING STREET ENTRY PORCH
MIDDLE UNIT ENTRY PORCH INTERIOR END UNIT ENTRY PORCH
20' - 0"21' - 0"6' - 0"24' - 0"24' - 0"x3' - 0"6' - 8"
x3' - 0" 6' - 8"
x3' - 0" 6' - 8"
x3' - 0" 6' - 8"
x3' - 0" 6' - 8"
9'-0"x8'-0" O.H.D.R @0' -7 5/8"179'-3" Ceiling @ Slab High Side
Slope Slab 1% toward O.H.D.
CLOSET
WATER
HTR
71' - 4"24' - 0"21' - 0"6' - 0"8' - 6"5' - 9"Sill: 3' - 0"F-19
2' - 6"x 3' - 0"2' - 0"20' - 0"
Planting Bed Planting Bed
36" Tall
Concrete
Planting Bed
36" Tall
Concrete
Planting Bed
1
a4.1
2
a4.1
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
1/4" = 1'-0"
a2.1
Level 1 Plan Triplex
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
0 1'4 81/4" = 1'-0"
1 Level 1 Plan
Please Note Duplex Unit is Similar
Dimensions, Omit center unit of Triplex.
REV. DATE REMARKS
RangeDWRefrigeratorRangeDWRefrigerator RangeDWRefrigerator
-
---
A B
2
1
AB
2
1
A B
2
15' - 8"8' - 4 1/4"23' - 0"16' - 2 1/8"
6' - 4 3/4"
6' - 5 1/4"4' - 11"9' - 11"14' - 1"12' - 1 1/2"13' - 2 1/4"10' - 9 3/4"
71' - 4"
24' - 0"R @0' -7 19/32"15R @0' -7 5/8"17Sill: 4' - 0"F-21
2' - 4"x 3' - 0"
x4' - 11
1/4"
6' - 7
1/2"
Sill: 4' - 0" F-21
2' - 4"x 3' - 0"
x2' - 8"6' - 8"
Sill: 4' - 0" F-20
5' - 0"x 3' - 0"
Sill: 4' - 0" F-20
5' - 0"x 3' - 0"
Sill: 4' - 0" F-20
5' - 0"x 3' - 0"
1
a4.1
2
a4.1
-
---
A B
2
1
AB
2
1
A B
2
1
71' - 4"
11' - 5 1/2"24' - 9 1/4"11' - 0 5/8"12' - 7 1/8"11' - 5 1/2"26' - 2"2' - 0"12' - 2"23' - 6 1/4"12' - 2"11' - 5 3/4"12' - 2"28' - 2"4' - 11"7' - 11"
2' - 7"4' - 11"7' - 10 7/8"8' - 11"11' - 7 3/8"
11' - 0"9' - 2"3' - 7 1/4"10' - 5"9' - 10 7/8"2' - 11 1/2"x2' - 6"6' - 8"
x2' - 6" 6' - 8"
x4' - 0" 6' - 8"x2' - 6" 6' - 8"
x2' - 6" 6' - 8"x2' - 6" 6' - 8"x2' - 6" 6' - 8"x2' - 6" 6' - 8"
Sill: 3' - 0"F-9
4' - 0"x 4' - 0"
Sill: 4' - 0" F-19
2' - 6"x 3' - 0"
Sill: 4' - 6" F-22
2' - 6"x 2' - 6"
Sill: 4' - 6" F-22
2' - 6"x 2' - 6"
Sill: 3' - 0"F-9
4' - 0"x 4' - 0"
Sill: 3' - 0"F-9
4' - 0"x 4' - 0"
1
a4.1
2
a4.1
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
1/4" = 1'-0"
a2.2
Level 2 & 3 Triplex
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
0 1'4 81/4" = 1'-0"
1 Level 2 Plan
0 1'4 81/4" = 1'-0"
2 Level 3 Plan
REV. DATE REMARKS
a3.22
a3.2
1
a3.1 1
a3.1
2
ARCHITECTURAL GRADE ASPHALT SHINGLE, BLACK , TYP.
a3.3
2
a3.31
a3.3 3
a3.3
4
1hr Rated Entry Awning Construction
@ THIS UNIT ONLY
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
1hr FIRE PARTITION
BETWEEN R-3 TWO FAMILY
DWELLINGS, TYPICAL
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
75' - 6"
11' - 6 1/2"28' - 9 1/4"9' - 0 5/8"14' - 7 1/8"11' - 6 1/2"30' - 2"2' - 0"51' - 10"
11' - 5 1/2"28' - 11"11' - 5 1/2"3" / 12"3" / 12"3" / 12"2" / 12"2" / 12"2" / 12"3" / 12"3" / 12"2" / 12"
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
1hr Rated Entry Awning Construction
@ THIS UNIT ONLY
1hr Rated Entry Awning Construction
@ THIS UNIT ONLY
PROVIDE 2HR FIRE BARRIER
BETWEEN 2ND AND 3RD UNIT.
-NON SPRINKLERED
TWO FAMILY
R-3 OCCUPANCY
-NON SPRINKLERED
-TYPE VB CONSTRUCTION
PROVIDE 2HR FIRE BARRIER
BETWEEN 2ND AND 3RD UNIT.
-NON SPRINKLERED
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
1/8" = 1'-0"
a2.3
Roof Plan
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
0 2 10 181/8" = 1'-0"1 ROOF PLAN
REV. DATE REMARKS
2" / 1 2"
2" / 12"
2" / 12"
-
---
3" / 12"2" / 12"8' - 1 1/8"8' - 1 1/8"1' - 4 3/4"8' - 1 1/8"1' - 4 3/4"8' - 2 5/8"1' - 5"36' - 8"TOP OF FOUNDATION
LEVEL 1 T.O.P.
LEVEL 2 T.O.S.
LEVEL 2 T.O.P.
LEVEL 3 T.O.S.
LEVEL 3 T.O.P.
PEAK
LEVEL 1 CLG. APPROX.9' - 7 5/8"SLAB @ OHD.
3" / 12"
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
As indicated
a3.1
Elevations
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
3/16" = 1'-0"
2 SOUTH - TRIPLEX
3/16" = 1'-0"
1 WEST - DAVIS LANE
ARCHITECTURAL ASPHALT ROOF -BLACK
WHITE GUTTER / DOWN
SPOUTS, TYP.
WHITE 7" FASCIA / 24" SOFFIT ; POWDER COATED ALUMINUM
TYPICAL EXTEIOR STRUCTURE
-8" TIMBER COLUMNS / BEAMS
-BROWN STAIN
SIDING TYPE 2
VINYL WINDOWS.WHITE
NOTES:
1) WINDOWS/DOORS @ LAP SIDING TO
HAVE TYPICAL 1X4 MIRATEC TRIM
PAINTED TO MATCH WINDOW FRAME
COLOR
2) NO WINDOW / DOOR TRIM @ STEEL
SIDING. PROVIDE J-CHANNEL.
3) FASCIA TO BE 2 PIECE BUILT UP
PAINTED WHITE
4) SOFFIT TO BE WHITE ROLLEX VENTED
PANELS
5) NO MATERIAL CHANGES TO OCCUR ON
OUTSIDE CORNERS.
6) ALL IN PLANE MATERIAL CHANGES
OCCUR AT HORIZONTAL BELLY BAND
SIDING TRIM.
7) EXPOSED CONCRETE FOUNDATION
MUST NOT EXCEED 18" IN HEIGHT.
6
SIDING TYPE 5 - LAP SIDING
LP SMART SIDE
-5" EXPOSURE
-WHITE FACTORY APPLIED PAINT
FINISH
7 SIDING TYPE 2 - VERTICAL DELTA RIB PANEL
24 GAUGE -CHARCOAL GRAY FACTORY COATING
WOOD TEXTURE DOOR -BARN RED PAINT
SIDING TYPE 1
BELLY BAND
TRANSITION
-CHARCOAL PAINT TO
MATCH METAL SIDING
3FT TALL RAISED CONCRETE PLANTNG BED
REV. DATE REMARKS
-
---
3" / 12"
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
3/16" = 1'-0"
a3.2
Elevations
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
3/16" = 1'-0"
1 NORTH - TRIPLEX
3/16" = 1'-0"
2
EAST INTERIOR UNITS
NOTES PER SHEET
BELLY BAND
TRANSITION
-PAINT TO MATCH
CHARCOAL SIDING
REV. DATE REMARKS
-
---STRUCTURE HEIGHT36' - 6"AVG. DISTANCE TO GRADE1' - 0"3 " / 1 2 "
3" / 12"
2" / 12"2" / 12 "TYPICAL BELLY BAND TRIM
-PAINT TO MATCH CHARCOAL SIDING
-
---
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
3/16" = 1'-0"
a3.3
Elevations
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
1
EAST - FEN WAY
2
SOUTH - DUPLEX, TYP.
3
WEST - DUPLEX
4 NORTH - DUPLEX
TYPICAL REAR
DOORS PAINTED
WHITE TO MATCH
SIDING
REV. DATE REMARKS
2
a4.1
-
---
1
a4.1
3 " / 1 2 "
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
1/4" = 1'-0"
a4.1
Sections
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
REV. DATE REMARKS
0 2 10 181/4" = 1'-0"
1 Section 1
0 2 10 181/4" = 1'-0"
2 Section 2
RIDGE VENT ROLL
-FASTEN PER MFG.
SHINGLES +
UNDERLAYMENT0' - 1 1 /2 "
SHINGLE RIDGE CAP
VENTED SPACE
ROOF FINISH PER ELEV.
1.5" AIR SPACE BAFFLE
1X4+1X8 FASCIA
2X BLOCKING
*NOTE= 1 HR. RATED EAVES @ OVERHANGS
W/IN 5'-0" OF SETBACK = ADD 5/8" TYPE X
G.W.B. TO UNDERSIDE OF SOFFET UNDER
SOFFET FINISH MATERIAL.
VENTED SOFFIT
PANELS -OR UTILIZE
LINEAR 2" SOFFET VENT
WITH BUG SCREEN. PER
ELEV. -VERIFY W/ G.C.
ROOF FINISH PER ELEV.
VENTED AIR SPACE
SIDEWALL ROOF VENT W/ FLASHING -PER MFG.
BUILDING EXTERIOR SIDEWALL .
ROOF SYSTEM
WRB -TYVEK OR SIMILIAR
SHEATHING PER STRUCT.
WALL INSULATION PER RESCHECK
1/2" G.W.B. -PRIMED / PAINTED
VAPOR BARRIER -PER IRC
2X6 WALL STUD
SIDING PER ELEV.
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
As indicated
a5.1
Architectural Details
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
3" = 1'-0"1
RIDGE VENT DETAIL - TYP.
1" = 1'-0"
2 EAVE DETAIL - RAFTER
1" = 1'-0"
3
SIDEWALL ROOF VENT DETAIL
1 1/2" = 1'-0"
4 TYP. EXTERIOR WALL
REV. DATE REMARKS
Yellow =MAXIM LIGHTING -
PATHFINDER MODEL 52120BK
=LED 15W
=880 LUMENS
=DARK SKY COMPLIANT
40fc
40fc
40fc
30fc
30fc
30fc
30fc20fc
10fc
10fc 20fc
20fc
20fc
20fc
30fc
40fc40fc40fc30fc30fc10fc10fc20fc20fc20fc30fc20fc20fc10fc10fc10fc40fc40fc40fc30fc30fc30fc30fc20fc20fc20fc20fc30fc40fc40fc40fc30fc30fc30fc30fc20fc20fc20fc20fc30fc10fc10fc10fc10fcSCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
1/4" = 1'-0"
e1.1
Photometric Light Study
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
0 1'4 81/4" = 1'-0"
1 Typical Duplex Exterior Lighting
SITE LIGHTING IS ENLARGED FOR CLARITY. EACH BUILDING TO HAVE SAME EXTERIOR FIXTURE / PHOTOMETRIC RESULTS.
REV. DATE REMARKS
GROSS BUILDING AREA
PER DWELLING UNIT = 1,676 SQFT
TOTAL EACH DUPLEX = 3,352 SQFT
TOTAL EACH TRIPLEX = 5,028 SQFT
UNIT CALCS.
• LEVEL 1 = 147 SQFT
• LEVEL 2 = 527 SQFT
• LEVEL 3 = 573 SQFT
TOTAL GROSS LIVING AREA PER UNIT = 1,247 SQFT
• GARAGE = 429 SQFT
TOTAL GROSS BUILDING AREA PER UNIT= 1,676 SQFT
LOT 4A COVERAGE = 2,880/15,327 = 19%
• LOT AREA =15,327 SQFT
• DUPLEX FOOTPRINT= 1,152 SQFT
• TRIPLEX FOOTPRINT= 1,728 SQFT
TOTAL LOT COVERAGE= 2,880 SQFT
LOT 4A F.A.R. (FLOOR AREA RATIO)= 8,380/15,506 = .55
• LOT AREA = 15,327 SQFT
• TOTAL FLOOR AREA = 8,380 SQFT
LOT 4B COVERAGE = 3,456/15,506 = 22%
• LOT AREA =15,327 SQFT
• TRIPLEX FOOTPRINT= 1,728 SQFT
• TRIPLEX FOOTPRINT= 1,728 SQFT
TOTAL LOT COVERAGE= 3,456 SQFT
LOT 4B F.A.R. (FLOOR AREA RATIO)= 10,056/15,506 = .65
• LOT AREA = 15,327 SQFT
• TOTAL FLOOR AREA = 10,056 SQFT
BUILDING AREA SUMMARY
LOT 4B
LOT 4A
PARK LAND TRACKING TABLE
SUBDIVION NAME: CATTAIL CREEK PHASE 2A / 2B
PROJECT NAME: CATTAIL DUPLEXES / LOT 4A & 4B
ACREAGE
ACREAGE PARK LAND AND/OR CIL REQUIRED:
ACREAGE PARK LAND AND/OR CIL PROVIDED:
REMAINING PARK LAND:
REMAINING ACREAGE PARK LAND AND/OR CIL REQUIRED:
VALUE OF IMPROVEMENTS IN LIEU PROPOSED:
ACREAGE OF PARK LAND PREVIOUSLY DEEDED TO C.O.B.
TOTAL FOR SUBDIV. LOT 4A&4B
-.57 ACRES
12 du .03 ACRES
10.2 du
1.8 du
(.03 x 43,560) x $1.60 = $2,090.88
N/A
10.2 du
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
As indicated
g1.0
Project Summary Notes
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
SHEET INDEX
g1.0 Project Summary Notes
g1.1 Plat Map
g1.2 Site Context Images
g2.0 Perspectives
C-1 SITE PLAN
C-2 GRADING PLAN
C-3 UTILITIES SITE PLAN
C-4 4" WATER MAIN-ALS
C-5 6" SEWER SERVICE-ALS
C-6 CIVIL DETAILS
C-7 CIVIL DETAILS
l2.1 Landscape Plan
a0.1 Schedules / Notes
a0.2 Fire Safety Notes
a0.3 Fire Separation Diagram
a2.1 Level 1 Plan Triplex
a2.2 Level 2 & 3 Triplex
a2.3 Roof Plan
a3.1 Elevations
a3.2 Elevations
a3.3 Elevations
a4.1 Sections
a5.1 Architectural Details
e1.1 Photometric Light Study
GENERAL NOTES
1. DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF THIS DESIGNER WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR
NOT. THESE DOCUMENTS ARE NOT TO BE REPRODUCED IN ANY FORM AND THEY ARE NOT TO BE USED BY THE PROJECT OWNER NOR ANY OTHER ENTITY ON ANY OTHER
PROJECTS EXCEPT BY WRITTEN AUTHORIZATION AND PERMISSION FROM THIS DESIGNER
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS AT THE JOB SITE AND SHALL NOTIFY THE DESIGNER OR GENERAL
CONTRACTOR OF ANY DISCREPANCIES, OMISSIONS, AND/OR CONFLICTS BEFORE PROCEEDING WITH THE WORK.
3. CONTRACTOR MUST COMPLY WITH THE RULES AND REGULATIONS OF AGENCIES HAVING JURISDICTION AND SHALL CONFORM TO ALL CITY, COUNTY, STATE AND
FEDERAL CONSTRUCTION, SAFETY AND SANITARY LAWS, CODES, STATUTES AND ORDINANCES.
4. EACH TRADE WILL PROCEED IN A FASHION THAT WILL NOT DELAY THE TRADES FOLLOWING THEM.
5. CONTRACTORS SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS AND/OR SPECIFICATIONS TO THE TRADES UNDER THEIR JURISDICTION.
6. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE, TRUE AND IN PROPER ALIGNMENT.
7. ALL MATERIAL SHALL BE NEW, UNUSED AND OF INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS.
8. THERE SHALL BE NO SUBSTITUTION OF MATERIALS OR PRODUCTS WHERE THEY ARE SPECIFIED. OWNER OR DESIGNER MUST APPROVE ALL SUBSTITUTES PROPOSED BY
CONTRACTORS.
9. ALL WORK AND MATERIAL SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF ATLEAST (1) ONE YEAR FROM APPROVAL FOR FINAL PAYMENT.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, DRILLING AND PATCHING REQUIRED FOR THEIR WORK AND NOT DAMAGE OR RENDER OTHER WORK AS
UNSATISFACTORY IN THE PROCESS.
11. CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE OF ACCUMALATION OF WASTE MATERIAS OR GARBAGE. PREMISES TO BE SWEPT CLEAN DAILY OF
REALTED CONSTRUCTION DEBRIS. AT THE COMPLETION OF THE WORK, LEAVE THE JOB SITE FREE OF ALL MATERIALS AND BROOM CLEAN.
12. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. LARGER SCALE DRAWINGS GOVERN SMALLER SCALE DRAWINGS.
13. PATCH ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO INSTALLING FLOOR COVERINGS OR CARPET.
14. CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED FOR WALL MOUNTED ACCESSORES, CABINETRY AND APPLIANCES AS NEEDED IN ORDER TO ACHIEVE A STRONG
AND DURABLE MOUNTING OF SUCH ITEMS.
15. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL WALK THROUGH WITH DESIGNER AND COMPLETE A PUNCH LIST OF ITEMS TO BE CORRECTED OR COMPLETED.
FINAL PAYMENT WILL BE CONTINGENT ON COMPLETION OF THIS PUNCH LIST.
16. ANY CHANGE WHICH RESULTS IN EXTRA COST REQUIRES AUTHORIZATION FROM OWNER OR DESIGNER PRIOR TO PROCEEDING WITH SUCH CHANGE.
17. THE SAFETY OF ERECTION, BRACING, SHORING AND TEMPORARY SUPPORTS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR WHO IS RESPONSIBLE FOR SAID SCOPE
OF WORK. THIS CONTRACTOR WILL BE RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE THROUGHOUT CONSTRUCTION.
18. CHANGES OR DEVIATIONS FROM THESE DRAWINGS MADE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE DESIGNER SHALL BE CONSIDERED UNAUTHORIZED AND
SHALL RESULT IN THE CONTRACOTR MAKING SUCH CHANGES TO OR DEVIATIONS FROM THE DRAWINGS BE HELD RESPONSIBLE FOR THE CONSEQUENCES RESULTING
FROM SUCH CHANGES.
APPLICABLE CODES
1. 2018 INTERNATIONAL RESIDENTIAL CODE
2. 2018 ENERGY CONSERVATION CODE
3. 2018 UNIFORM PLUMBING CODE
4. 2018 INTERNATIONAL MECHANICAL CODE
5. 2017 NATIONAL ELECTRIC CODE
PROJECT SUMMARY
PROJECT ADDRESS: 2983 FEN WAY BOZEMAN, MT 59718
(#2979 LOT 4B SEPERATE PERMIT)
LEGAL DESC. CATTAIL CREEK PH 2 / BL 12 / LOT 4A (LOT
4B MIRRORED)
LOT AREA: LOT 4A 15,327 SQFT (LOT 4B 15,506 SQFT)
ZONING: R3
CURRENT USE: VACANT LOT W/ UTILITIES
BUILDING TYPE: DUPLEX W/ ATTACHED GARAGE
BUILDING HT.: 24'-0" ADJ. GRADE
# OF STORIES 2
CONSTRUCTION TYPE: TYPE-V B
INSULATION AND FENESTRATION
1. EXTERIOR WINDOWS - LOW-E 272 W/ ARGON GAS - U-FACTOR .31
2. EXTERIOR DOORS - U FACTOR .35
3. EXTERIOR WALL ASSEMBLY - R-21 UNFACED BATT W/ POLYFILM 4M
CLEAR
4. EXTERIOR FOUNDATION WALL - R-19 POLYFACED BATT W/ 3" FOAM
FILLED RIM JOIST
5 CATHEDRAL CIELING - R-48 - VENTED W/ BAFFLES
6 VENTED ATTIC SPACE - R-48 - VENTED WITH BAFFLES
7 FLOOR ABOVE GARAGE - R-30 BATT
8 GARAGE WALLS - R-21 UNFACED BATT W/ POLYFILM 4M CLEAR
9 GARAGE CEILING - R-48 - VENTED W/ BAFFLES
RADON MITIGATION DATA
1. ADHERE TO IRC SECTION AF103.1 FOR RADON CONSTRUCTION
TECHNIQUES.
2 CONSTRUCTION TECHNIQUES RESIST ENTRY OF RADON AND
ALLOW FOR POST-CONSTRUCTION MITIIGATION IF NECESSARY.
3 SUMMARY OF CONSTRUCTION TECHNIQUES - DAMPROOFING @
EXTERIOR FOUNDATION WALLS + 4" GRAVEL DRAINAGE COURSE
UNDER 6MIL. POLYETHYLENE SOIL-GAS-RETARDER W/ 12"
LAPPED & TAPED SEAMS EXTENED TO FOUNDATION WALL.
4 G.C. TO COORDINATE PASSIVE VETNING RADON SYSTEM UP
THROUGH ROOF; INSTALL EXHAUST FAN IF HIGH LEVELS ARE
TESTED.
AERIAL
REV. DATE REMARKS
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
g1.2
Site Context Images
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
SOUTH EDGE OF LOT 4B; LOOKING WEST LOT 4A & 4B; LOOKING WEST NORTH EDGE OF LOT 4A ; LOOKING WEST
EXISTING NORTH NEIGHBOR ; LOOKING WEST EXISTING NORTH NEIGHBOR DRIVE ACCESS ; LOOKING WEST EXISTING NORTH NEIGHBOR INTERIOR DRIVE AREA ; LOOKING EAST
EXISTING MULTI-FAMILY, SOUTH 1 BLOCK; LOOKING WEST
REV. DATE REMARKS
SCALE:
DATE:
DRAWN BY
PROJECT NO:
SHEET NO.
SHEET TITLE:
PROJECT/CLIENT
MILLER DESIGN BUILD, LLC
BOZEMAN, MT 59715
406.531.9671
millerdesignbuild@gmail.com
SCOTT R. MILLER
DESIGNER
STRUCTURAL ENGINEER
DIXSON & COMPANY, INC.
PoBox 6099
BOZEMAN, MT 59771
BUILDER
406.388.7337
dixsonandcompanyinc@gmail.com
JOE DIXSON
g2.0
Perspectives
CATTAIL DUPLEXES
sm
9-09-2021
0620
2979 & 2983 FEN WAY
Bozeman, MT 59718
SITE PLAN REVIEW
DIXSON & COMPANY, inc.
REV. DATE REMARKS