18-PLEX BLDG # 2A2.11/8"=1'-0"1/8"=1'-0"THIRD FLOOR PLAN 18-PLEXAA2.1DECKUNIT CWDSTORAGESTORAGEDECKUNIT CWDSTORAGESTORAGEDECKUNIT CWDWHWHWHDECKUNIT DWDSTORAGESTORAGEDECKUNIT CWDWHWHDECKUNIT DWDWHD.W.REF.D.W.REF.D.W.REF.D.W.REF.D.W.REF.D.W.REF.DNDNDN26'-0"12'-0"26'-0"26'-0"12'-0"26'-0"26'-0"12'-0"26'-0"42'-0"192'-0"42'-0"14'-2"11'-10"26'-0"12'-0"14'-2"23'-7 249/256"14'-2"12'-0"14'-2"23'-8"14'-2"12'-0"14'-2"11'-10"52'-0"52'-0"192'-0"16'-0"10'-0"AS3.1AS3.2AS31/2" G.W.B.2x4 OR 2x6STUDS @ 16"O.C. AS REQ'DWALL TYPENOT RATED1/2" G.W.B.W12X6 WOOD STUDS @16" O.C.1/2" STRUCTURALSHEATHING5 1/2" FIBERGLASS R-21BATT INSUL.5/8" TYPE "X" GYP. BD. ATTACH W/1" TYPE "S" DRYWALL SCREWS @12" O.C.1-HOUR GA FILE NO. WP 8105WALL TYPEW4INTERIORSTORAGE AREABUILDING WRAP5/8" TYPE "X" GYP. BD. ATTACH W/1" TYPE "S" DRYWALL SCREWS @12" O.C.VAPOR BARRIER2X6 WOOD STUDS @ 16" O.C.1/2" STRUCTURAL SHEATHING ATSHEAR WALLS (SEE STRUCTURAL FORATTACHMENT REQUIREMENTS)5 1/2" FIBERGLASS R-21BATT INSUL.5/8" TYPE "X" GYP. BD. ATTACH W/1" TYPE "S" DRYWALL SCREWS @12" O.C.1-HOUR GA FILE NO. WP 8105INTERIORBUILDING WRAPONE LAYER 48" WIDE 5/8" TYPE "X"EXTERIOR RATED GYPSUMSHEATHINGEXTERIOR FINISH, SEE ELEVATIONSEXTERIORGYPSUM WALLBOARD, GYPSUM SHEATHING, WOOD STUDSEXTERIOR SIDE: ONE LAYER 48" WIDE 5/8" TYPE X GYPSUM SHEATHING APPLIED PARALLEL TO 2X4 WOOD STUDS 24" O.C. WITH 1 3/4" GALVANIZED ROOFINGNAILS 4" O.C. AT VERTICAL JOINTS AND 7" O.C. AT INTERMEDIATE STUDS AND TOP AND BOTTOM PLATES. JOINTS OF GYPSUM SHEATHING MAY BE LEFTUNTREATED. EXTERIOR CLADDING TO BE ATTACHED THROUGH SHEATHING TO STUDS.INTERIOR SIDE: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD, WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE APPLIED PARALLEL ORAT RIGHT ANGLES TO STUDS WITH 6D COATED NAILS, 1 7/8" LONG, 0.0915" SHANK, 1/4" HEADS, 7" O.C. (LOAD BEARING)WALL TYPEW3GYPSUM WALLBOARD, GYPSUM SHEATHING, WOOD STUDSEXTERIOR SIDE: ONE LAYER 48" WIDE 5/8" TYPE X GYPSUM SHEATHING APPLIED PARALLEL TO 2X4 WOOD STUDS 24" O.C. WITH 1 3/4" GALVANIZED ROOFINGNAILS 4" O.C. AT VERTICAL JOINTS AND 7" O.C. AT INTERMEDIATE STUDS AND TOP AND BOTTOM PLATES. JOINTS OF GYPSUM SHEATHING MAY BE LEFTUNTREATED. EXTERIOR CLADDING TO BE ATTACHED THROUGH SHEATHING TO STUDS.INTERIOR SIDE: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD, WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE APPLIED PARALLEL ORAT RIGHT ANGLES TO STUDS WITH 6D COATED NAILS, 1 7/8" LONG, 0.0915" SHANK, 1/4" HEADS, 7" O.C. (LOAD BEARING)2X6 WOOD STUDS @16" O.C.1/2" STRUCTURALSHEATHING WHERE REQ'DSEE STRUCTURAL3" FIBERGLASS BATT INSUL.RESILIENT CHANNEL 24" O.C.ONE SIDE ATTACH W/ 1-1/4"TYPES DRYWALL SCREENSEND JOINTS BACK BLOCKED W/RESILIENT CHANNEL5/8" TYPE "X" GYP. BD. ATTACHW/ 1" TYPE "S" DRYWALLSCREENS @ 12" O.C.5/8" TYPE "X" GYP. BD. ATTACH W/1" TYPE "S" DRYWALL SCREWS @12" O.C.1-HOUR50 STCWALL TYPEUL DES U327W23RD FLOOR CEILINGGA FILE NO. RC 2603WOOD ROOF TRUSSES, RESILIENT CHANNELS, GLASS OR MINERAL FIBER INSULATION,CEILING DAMPER, GYPSUM WALLBOARD.PROPRIETARYONE LAYER 5/8" PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHTANGLES TO RESILIENT FURRING CHANNELS 12" O.C. WITH 1 1/8" TYPE S DRYWALL SCREWS 8" O.C. GYPSUMBOARD END JOINTS ATTACHED WITH SCREWS 8" O.C. TO ADDITIONAL PIECES OF CHANNEL 60" LONGLOCATED 3" BACK ON EITHER SIDE OF END JOINT. RESILIENT CHANNELS APPLIED AT RIGHT ANGLES TOBOTTOM CHORD OF PITCHED WOOD TRUSSES 24" O.C. WITH 1 1/4" TYPE S OR W SCREWS. GLASS FIBEROR MINERAL FIBER BATT OR LOOSE FILL INSULATION APPLIED DIRECTLY OVER GYPSUM BOARD. TRUSSESSUPPORTING 15/32" PLYWOOD OR OSB ROOF SHEATHING APPLIED AT RIGHT ANGLES TO TRUSSES WITHCONSTRUCTION ADHESIVE AND 6D RING SHANK NAILS 12" O.C. OPTIONAL CEILING DAMPER (REFER TOMANUFACTURER FOR INFORMATION ON THE TYPE OF DAMPER).PROPRIETARY GYPSUM BOARDNATIONAL GYPSUM COMPANY - 5/8" GOLDBOND BRAND FIRE-SHIELD C GYPSUMWALLBOARD1-HOUR1" LIGHTWEIGHT CONC.TOPPING SLAB3/4" 48/24 APA RATED T&GSUBFLOOR11 7/8" TJIMINIMUM 3-1/2" THICKFIBERGLASS INSULATION HELDUNDER SUBFLOORRESILIENT CHANNEL AT 16" O.C.5/8" TYPE 'C' G.W.B.FLOOR @ CRAWL SPACE & 2ND & 3RD FLOORSUL L5701-HOUR59 STCNTSINTERIOR WALLBA2.1NTSEXTERIOR WALLCA2.1NTSFLOOR/CEILINGGA2.1NTSCEILINGHA2.1NTSCOMMON WALLDA2.1W4W4W4W2W2W3W3W3W3W3W3NTSSTORAGE WALLEA2.16'-0"6'-0"10'-0"16'-0"16'-0"10'-0"10'-0"16'-0"16'-0"10'-0"10'-0"16'-0"6'-0"
6'-0"
6'-0"
6'-0"W1W1W1W1W1W1W1W1W1W1W1W1W3W3W3W3W3W3PROVIDE 20MIN. RATED DOORSAT ALL STORAGE &FIRE RISER ROOMS26'-0"15'-9 63/64"9'-3"16'-11 1/64"
15'-9 63/64"9'-3"16'-11 1/64"PROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISHA.1S4.1A.1S4.12'-0"
2'-0"3 1/2" DROPPED SOFFIT ASREQ'D FOR SPRINKLER SYSTEM,TYP.PROVIDE 3-1/2" SOFFIT ALL FLOORS FOR FIRESPRINKLERS AND DUCTS, TYPIBC 1209.222"x30" MIN. ATTICACCESS W/ MIN. 30"CLEAR HEADROOM, TYP.NOTE:TOILETS MUST BE WATERSENSE LABELED (1.28GAL/FLUSH)SHOWERS MUST BE WATERSENSE LABELED (1.5 GPM)CLOTHES WASHERS MUST BE CEE TIER RATED(WATER FACTOR OF 4.0 OR LESS)PENETRATIONS OF FIRE-RESISTIVE WALLS,FLOOR-CEILINGS, AND ROOF-CEILINGS SHALL BEPROTECTED AS REQ'D IN IBC SECTION 714AC UNIT, TYP.ELECTRIC WATER HEATER TYP.F155.6 SQ. FT.55.6 SQ. FT.55.6 SQ. FT.55.6 SQ. FT.PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.9/27/19 JDS2X6 WOOD STUDS @ 16" O.C.1/2" STRUCTURAL SHEATHING ATSHEAR WALLS (SEE STRUCTURAL FORATTACHMENT REQUIREMENTS)5 1/2" FIBERGLASS R-21BATT INSUL.1/2" TYPE "X" GYP. BD. ATTACH W/1" TYPE "S" DRYWALL SCREWS @12" O.C.INTERIORBUILDING WRAPEXTERIOR FINISH, SEE ELEVATIONSEXTERIORWALL TYPEW5NTSEXTERIOR WALLFA2.12'-0"
2'-0"18-060JDSRBT55.6 SQ. FT.55.6 SQ. FT.