HomeMy WebLinkAbout002 A2 FIRST & SECOND FLOOR PLANS-BLDG 1DESCRIPTION:NO:DATE:DRAWN BY:CHECKED BY:JOB NO:PLOT SCALE:BY:2004-2022 JDS ARCHITECTSc03-25-22BOZEMAN MONTANA BOULDER CREEK - PHASE 2 STAMPNo. 2557SOBREPENAJESSE D.ANATNOMFOE T ATS TANAMONEMANBOZENSELICARCDHI TECT ABIGAIL LANE 12-PLEX BLDG #1 PATIOTYPE B UNITADAADAPTABLEWDSTORAGEPATIOTYPE B UNITADAADAPTABLEWDPATIOTYPE A UNITWDSTORAGESTORAGEPATIOTYPE B UNITWDUPADAADAPTABLEADAACCESSIBLEWHUPWHWHWHD.W.REF.D.W.REF.D.W.REF.D.W.REF.RISER ROOMWDSTORAGESTORAGEDWUPDNDNDECKDECKUNIT CUNIT DWHWHD.W.REF.D.W.DWSTORAGESTORAGEWDUPDNDNDECKDECKUNIT CUNIT DWHWHD.W.REF.D.W.REF.REF.1/8"=1'-0"FIRST FLOOR PLAN 12-PLEXAA21/8"=1'-0"SECOND FLOOR PLAN 12-PLEXBA226'-0"12'-0"26'-0"26'-0"12'-0"26'-0"42'-0"128'-0"14'-2"11'-10"26'-0"12'-0"14'-2"23'-8"14'-2"12'-0"14'-2"11'-10"52'-0"26'-0"128'-0"16'-0"10'-0"26'-0"12'-0"26'-0"26'-0"12'-0"26'-0"16'-0"10'-0"26'-0"12'-0"52'-0"12'-0"26'-0"MIN. 32" HIGH SPLIT FACE CMUWALL AT PATIO AREAS, TYP.,SEE DETAIL B/A3.1AS3.1AS3.2AS3AS3.1AS3.2AS3W4W4W2W5W5W5W5W5W5W5W5W5W5W5W5W5W5W4W4W210'-0"16'-0"16'-0"10'-0"10'-0"16'-0"6'-0"16'-0"10'-0"10'-0"16'-0"16'-0"10'-0"6'-0" 6'-0" 6'-0" 6'-0" 16'-11"9'-3"15'-10"W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W18'-6"W3W3W3W314'-2"11'-10"14'-2"11'-10"11'-10"14'-2"14'-2"11'-10"42'-0" 42'-0" 16'-11"9'-3"15'-10" 14'-10"9'-11 1/2"17'-2 1/2"PROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISHPROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISHAS4.1AS4.12'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0"PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.42'-0"16'-11"9'-3"15'-10"128'-0"128'-0"3'-4" OPENING IN PATIO WALL ON SIDEWHERE PATIOS ARE ADJACENT TO EACHOTHER, TYP.NOTE:TOILETS MUST BE WATERSENSE LABELED (1.28GAL/FLUSH)SHOWERS MUST BE WATERSENSE LABELED (1.5 GPM)CLOTHES WASHERS MUST BE CEE TIER RATED(WATER FACTOR OF 4.0 OR LESS)PENETRATIONS OF FIRE-RESISTIVE WALLS,FLOOR-CEILINGS, AND ROOF-CEILINGS SHALL BEPROTECTED AS REQ'D IN IBC SECTION 714PROVIDE 3 1/2"SOFFIT AT ALLFLOORS FOR FIRE SPRINKLERSAND DUCTS, TYPPROVIDE 3 1/2"SOFFIT AT ALLFLOORS FOR FIRESPRINKLERSAND DUCTS, TYPAC UNIT, TYP.PROVIDE KNOX BOX FORFIRE CONTROL ROOMACCESS TYP.20'-4"5'-0"TOTAL BUILDING AREA12,996 S.F.4,332 S.F.AREA 1ST FLOOR AREA TABULATIONS4,332 S.F.AREA 2ND FLOOR AREA 3RD FLOOR 4,332 S.F.1,083 S.F.UNIT TYPE "A"UNIT AREAS1,083 S.F.UNIT TYPE "B"UNIT "C"1,083 S.F.UNIT "D"1,083 S.F.ELECTRIC WATERHEATER TYP.ELECTRIC WATER HEATER TYP.ELECTRIC WATER HEATER TYP.PROVIDE 20MIN. RATEDDOORS AT ALL STORAGE &FIRE RISER ROOMSPROVIDE 20MIN. RATEDDOORS AT ALL STORAGE &FIRE RISER ROOMS(13) ELEC.METERS ANDELECTRICALSERVICEPROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.PROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISHPROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISH89 SQ. FT.89 SQ. FT.89 SQ. FT.89 SQ. FT.6'-0" 6'-0"55.6 SQ. FT.55.6 SQ. FT.55.6 SQ. FT.55.6 SQ. FT.W3W3W3W3W5A21/8"=1'-0"18-060JDSRBT2" WATER SERVICE4" FIRE RISER18-2-206'-0"PROVIDE KNOX BOX FORFIRE CONTROL ROOMACCESS TYP.F.D.SIAMESE CONNECTION3'-10" 3'-10" 3'-10" 3'-10"