HomeMy WebLinkAbout046 Landscape DetailsLANDSCAPE DETAILS LS500 PERENNIAL PLANT LAYOUT SCALE: 1" = 1'-0" ON CENTER SPACING NOTES: 1.WHEN PLANTED ON A CURVE, ORIENT ROWS TO FOLLOW THE LONG AXIS OF AREAS WHERE PLANTS ARE MASSED. SPECIFIED MULCH, REFER TO MATERIAL SCHEDULE, SHEET L-XXX AMENDED PLANTING BED TILLED TO A DEPTH OF 6" CENTER OF PLANT 1 2 3 1 2 3 SECTION PLAN PLAN ON CURVE NOTE: 1.BROKEN OR CRUMBLING ROOT-BALLS WILL BE REJECTED. 2.CARE SHOULD BE TAKEN NOT TO DAMAGE THE SHRUB OR ROOT-BALL WHEN REMOVING IT FROM ITS CONTAINER. 3.ALL JUNIPERS SHOULD BE PLANTED SO THE TOP OF THE ROOT-BALL OCCURS ABOVE THE FINISH GRADE OF THE MULCH LAYER. 4.DIG PLANT PIT TWICE AS WIDE AND AS HIGH AS THE CONTAINER. 5.PRUNE ALL DEAD OR DAMAGED WOOD PRIOR TO PLANTING, DO NOT PRUNE MORE THAN 20% OF LIMBS. SHRUB PLANTING SCALE: 1 1/2" = 1'-0" SET SHRUB ROOT-BALL 1" HIGHER THAN FINISH GRADE FINISH GRADE (TOP OF MULCH) SPECIFIED MULCH, REFER TO MATERIAL SCHEDULE, SHEET L-XXX TILL IN SPECIFIED SOIL AMENDMENT TO A DEPTH OF 8" IN BED BACKFILLED AMENDED SOIL UNDISTURBED SOIL 1 2 3 4 5 62X CONTAINER WIDTH 1X CONTAINER HEIGHT 3 4 5 6 2 1 2X ROOT BALL DIAMETER 120° 120°PRUNING NOTES: 1.ALL PRUNING SHALL COMPLY WITH ANSI A300 STANDARDS. 2.DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND BROKEN BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED. HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. STAKING NOTES: 1.STAKE TREES PER FOLLOWING SCHEDULE, THEN REMOVE AT END OF FIRST GROWING SEASON. a.1-1/2" CALIPER SIZE - MIN. 1 STAKE ON SIDE OF PREVAILING WIND (GENERALLY N.W. SIDE). b.1-1/2" - 3" CALIPER SIZE - MIN. 2 STAKES - ONE ON N.W. SIDE, ONE ON S.W. SIDE (OR PREVAILING WIND SIDE AND 180° FROM THAT SIDE). c.3" CALIPER SIZE AND LARGER - 3 STAKES PER DIAGRAM. 2.WIRE OR CABLE SHALL BE MIN. 12 GAUGE, TIGHTEN WIRE OR CABLE ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. NYLON STRAPS SHALL BE LONG ENOUGH TO ACCOMMODATE 1-1/2" OF GROWTH AND BUFFER ALL BRANCHES FROM WIRE. ROOT BARRIER NOTES: 1.INTRODUCE A ROOT BARRIER FOR TREES PLACED WITHIN LANDSCAPE ISLANDS OR NEAR STORM DRAINS. TREE PLANTING DETAIL SCALE: 3/16" = 1'-0" 1 2 3 4 5 6 7 14 13 12 11 10 9 8 PLACE MINIMUM 1/2" PVC PIPE AROUND EACH WIRE, EXPOSED WIRE SHALL BE MAXIMUM 2" EACH SIDE 6'-0"UNTREATED WOOD POST, MINIMUM 1.5" DIAMETER, ALL SHALL BE DRIVEN OUTSIDE ROOTBALL AND IN UNDISTURBED SOIL TREE WRAP TO BE INSTALLED ONLY FROM OCTOBER 1 THROUGH APRIL 30, DECIDUOUS ONLY, WRAP FROM BASE OF TRUNK TO BOTTOM LIMB PLANT TREE SO THAT TOP MOST MAJOR ROOT IS 1"-2" ABOVE FINISHED GRADE 2'-0" RADIUS MULCH RING, VENTERED ON TRUNK, 3" DEPTH, DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK, FINISHED GRADE REFERENCES TOP OF MULCH 1:1 SLOPE ON SIDES OF PLANTING HOLE ROPES AT TOP OF ROOTBALL SHALL BE CUT, REMOVE TOP 1/3 OF BURLAP, NON-BIODEGRADABLE MATERIAL SHALL BE TOTALLY REMOVED GROMMETED NYLON STRAPS GALVANIZED WIRE, MINIMUM 12 GAUGE CABLE,TWIST WIRE ONLY TO KEEP FROM SLIPPING 4-6" HIGH WATER SAUCER IN NON-TURF AREAS BACKFILL WITH BLEND OF EXISTING SOIL AND A MAXIMUM 20%, BY VOLUME, ORGANIC MATERIAL, WATER THOROUGHLY WHEN BACKFILLING 2'-0" STEEL T-POST, ALL SHALL BE DRIVEN BELOW GRADE AND OUTSIDE ROOTBALL IN UNDISTURBED SOIL PLACE SOIL AROUND ROOT BALL FIRMLY, DO NOT COMPACT OR TAMP, SETTLE SOIL WITH WATER TO FILL ALL AIR POCKETS PLACE ROOT BALL ON UNDISTURBED SOIL TO PREVENT SETTLEMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PLAN VIEW - THREE STAKES P R E V A I L I N G W I N D 1 2 5 3 CMU SITE WALL SCALE: 3/4" = 1'-0" NOTES: 1.REFER TO THE GEOTECHNICAL REPORT FOR SPECIFIC CONDITIONS RELATED TO THIS DETAIL. 2.SEATWALL SHALL BE INSTALLED SO HORIZONTAL CURVES ARE SMOOTH AND FREE-FLOWING AS SHOWN ON PLANS. PRECAST CONCRETE CAP, SLOPE TO DRAIN; INSTALL 1/2" CHAMFER ON BOTH SIDES OF CAP, RE: MATERIALS SCHEDULE 8X8X16 REINFORCED CMU, STRUCTURAL FOR REINFORCEMENT FULL SIZE BRICK VENEER, STEEL CITY BLEND TO MATCH ARCHITECTURE 1" AIR GAP #4 VERTICAL REBAR AT 24" O.C., CENTERED IN WALL; ALTERNATE DOWEL HOOK DIRECTION IN FOOTING GROUND COVER, SEE LANDSCAPE PLAN FOR SURFACE TREATMENT 3" PVC PIPE, 4' O.C. FOR WATER DRAINAGE REINFORCED CONCRETE FOUNDATION, RE: STRUCTURAL, 3'-0" TO FROST DEPTH 12 GA/ WIRE ANCHOR @ 12" O.C. 1 2 3 4 5 6 7 8 9 ELEVATION ROUGH-IN FOR LED MOUNTED WALL LIGHT WITH PVC CONDUIT FOR POWER; LIGHT TO BE FLUSH WITH STONE VENEER; RE: LANDSCAPE PLAN FOR LAYOUT DIMENSIONS, RE: ELECTRICAL FOR LIGHTING SPECIFICATIONS AND CONNECTIONS CONDUIT; RE: ELECTRICAL FOR SPECIFICATIONS TERMINATION BAR CONCRETE FLATWORK; RE: LANDSCAPING PLANS FOR PAVING TYPE, RE: CIVIL FOR DEPTH AND GRADING EXPANSION JOINT, CONTRACTOR TO INSTALL CLEAR HEAVY DUTY ELASTOMERIC CAULK FINISH GRADE 10 11 12 13 14 15 SITE WALL SECTION 1 3 15 CL EQ REFER TO DIMENSIONING PLAN FOR LENGTH 7 4'-0" O.C. 1'-6" 3'-0" 2 3 8 13 6 10 11 1 7 9 4 12 EQ EQ EQ 5 14 10 WALL LIGHT 2'-0" O.C. STEEL EDGER DETAIL SCALE: 1" = 1'-0" NOTES: 1. THERE SHALL BE NO EXPOSED SHARP / JAGGED EDGES. 2. CONTRACTOR SHALL INSTALL STAKES AS REQUIRED BY THE MANUFACTURER. FINISHED GRADE - TOP OF SOD THATCH LAYER AND TOP OF MULCH OR CRUSHER FINES SHALL BE FLUSH WITH TOP OF EDGER TURF THATCH AMENDED SOIL PER SPECIFICATIONS SUBGRADE ROLLED TOP STEEL EDGER - DRILL (16) 1/2" DIA. HOLES 1" O.C. MIN. AT ALL LOW POINTS OR POORLY DRAINING AREAS IN ORDER TO ENSURE ADEQUATE DRAINAGE EDGER STAKE 1 2 3 4 5 6 4 3 2 1 5 ENSURE POSITIVE DRAINAGE 6 SECTION LONGITUDINAL SECTION OF EDGER AT LOW POINT (16) 1/2" DIA. HOLES MIN. AT ALL LOW POINTS 4 OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:LOTS 1A & 3A OF EASTLAKE PROFESSIONAL CENTER SUBDIVISION MASTER SITE PLAN MODIFICATION FOR TOWNPLACE SUITESNORTHEAST CORNER OF N27TH AVE AND HONOR LANE | BOZEMAN, MTBRAXTON DEVELOPMENT 1735 S. 19TH AVE. SUITE B BOZEMAN, MT 59718 406.582.8100 JB, REJS01/25/23: MASTER SITE PLAN MODIFICATION 05/19/23: MASTER SITE PLAN MODIFICATION R 1101 Bannock Street Denver, CO 80204 P 303.892.1166 www.norris-design.com