Loading...
HomeMy WebLinkAbout001 - A0-1 - COVER SHEET1View Name1/8" = 1'-0"SCALE101A5A3-83A5-2A00Room name202BUILDING SECTIONSSEE DRAWINGSEX: SHEET A3-8, DETAIL 5WALL SECTIONSSEE DRAWINGSEX: SHEET A5-2, DETAIL 3EXTERIOR ELEVATIONSEE DRAWINGSEX: SHEET A7-1, DETAIL 4CONSTRUCTION DETAILSEE DRAWINGSEX: SHEET A6-3, DETAIL 2INTERIOR ELEVATIONSEE DRAWINGSEX: SHEET A7-1, DETAIL 4 & 5DOOR SYMBOLSEE DOOR SCHEDULEWINDOW SYMBOLSEE WINDOW TYPESROOM SYMBOLEX: 202 -SECOND FLOORGRID LINES:LETTERS LEFT TO RIGHTNUMBERS BOTTOM TO TOPWALL/PARTITION TYPE SYMBOLSEE WALL/PARTITION TYPESBENCHMARKREFERENCE SYMBOLSsE25A3-81A101SIMA7-14A7-145A1THIS PROJECT SHALL COMPLY WITH THESE CODES, OR LATER EDITIONS AS REQUIRED BY THE STATE OF MONTANA:2012INTERNATIONAL RESIDENTIAL CODE2012INTERNATIONAL MECHANICAL CODE2012UNIFORM PLUMBING CODE2012NATIONAL ELECTRIC CODE2014INTERNATIONAL ENERGY CONSERVATION CODENO HAZARDOUS MATERIALS EXCEEDING THE LIMITS STATED IN THE 2003 INTERNATIONAL BUILDING CODE TABLES 414.2.4 AND 414.5.1 WILL BE STORED IN THIS BUILDING.CODE REQUIREMENTSALL DRAWINGS AND DESIGN INFORMATION: CONSTRUCTIVE SOLUTIONS, INC., COPYRIGHT 2019.THIS SET OF CONSTRUCTION DOCUMENTS IS GENERATED FROM AN INTELLIGENT, 3 DIMENSIONAL COMPUTER MODEL. THIS CONSTRUCTION DOCUMENT SET IS REPRESENTATIVE OF THE CONDITIONS ACTUALLY MODELED THAT CAN BE SHOWN. NOTE:GENERAL NOTES1. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.2. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NEW MATERIALS (U.N.O.) & QUALIFIED CRAFTPERSONS TO COMPLETE THE WORK.3. ALL WORK SHALL BE PERFORMED BY SKILLED AND QUALIFIED WORKMEN IN ACCORDANCE WITH THE BEST PRACTICES OF THOSE TRADES INVOLVED, AND IN COMPLIANCE WITH CURRENT BUILDING REGULATIONS AND CODES, AND/OR GOVERNMENTAL LAWS, STATUTES, OR ORDINANCES CONCERNING THE USE OF UNION LABOR.4. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT & MAY NOT SHOW MINOR DETAILS OF PROPOSED INSTALLATION. THE INCLUSION OF THESE MINOR DETAILS IS IMPLIED TO PROVIDE A COMPLETE PROJECT & ARE TO BE INCLUDED AS A PART OF A BID.5. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUB FLOOR (A.S.F.) UNLESS NOTED OTHERWISE.6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT EXISTING CONDITIONS PRIOR TO PROCEEDING WITH EACH INSTALLATION OR PART OF THE WORK. DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING.7. THE CONTRACTOR IS TO COORDINATE THE INSTALLATION OF MATERIALS & WORK OF OTHERS WHO ARE NOT SUB-CONTRACTORS TO THE G.C., YET ARE REQUIRED IN PROVIDING A COMPLETED PROJECT. AREAS OF WORK REQUIRING COORDINATION INCLUDE BUT ARE NOT LIMITED TO THOSE INDICATED AS N.I.C. ON THE CONSTRUCTION DOCUMENTS.8. REFER TO STRUCTURAL, MECHANICAL & ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.9. ALL DIMENSIONS ARE FROM FACE OF STUD UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL VERIFY ALL DIMENSION CONDITIONS PRIOR TO CONSTRUCTION.10. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN DRAWINGS & SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR BIDDING PURPOSES. BRING ALL CONTRADICTIONS, CONFLICTS, AMBIGUITIES OR DISCREPENCIES TO THE ATTENTION OF CONSTRUCTIVE SOLUTIONS, INC. IMMEDIATELY. FAILURE TO PROVIDE NOTICE TO CONSTRUCTIVE SOLUTIONS, INC. PRIOR TO ANY SUBSEQUENT CONSTRUCTION ACTIVITY SHALL RELIEVE CONSTRUCTIVE SOLUTIONS, INC. OF ALL LIABILITIES AND/ OR ANY OTHER CONSEQUENCES.11. THE CONSTRUCTION DOCUMENTS CONSIST OF THE CONSTRUCTION DRAWINGS & SPECIFICATIONS INCLUSIVELY. SOME ITEMS MAY BE SHOWN ONLY ON THE DRAWINGS OR INDICATED ONLY IN THE SPECIFICATIONS. FOR EXAMPLE, THE SPECIFICATIONS MAY SAY TO PAINT ALL EXPOSED STRUCTURAL STEEL, BUT THIS WILL NOT BE CALLED OUT ON ALL OF THE DRAWINGS.12. 3-D VIEWS MAY BE USED THROUGHOUT THE CONSTRUCTION DOCUMENTS. 3-D VIEWS ARE SHOWN TO CLARIFY CONDITIONS THAT CANNOT BE SHOWN IN OTHER VIEWS. 3-D VIEWS MAY NOT SHOW ALL DETAILS REQUIRED TO COMPLETE THE AREA. REFER TO DETAILS AT ADJACENT AREAS AS NECESSARY OR ASK THE ARCHITECT PRIOR TO BIDDING.13. DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF CONSTRUCTIVE SOLUTIONS, INC. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED AND CONSTRUCTED OR NOT. THESE DOCUMENTS ARE NOT TO BE REPRODUCED IN ANY FORM AND THEY ARE NOT TO BE USED BY THE PROJECT OWNER OR ANY OTHER ENTITY ON ANY OTHER PROJECTS OR FOR ANY EXTENSION, ADDITION OR ALTERATIONS TO THE ORIGINAL PROJECT EXCEPT BY WRITTEN AUTHORIZATION AND PERMISSION FROM AND AGREEMENT WITH CONSTRUCTIVE SOLUTIONS, INC.14. CHANGES TO OR DEVIATIONS FROM THE DRAWINGS MADE WITHOUT THE EXPRESS WRITTEN CONSENT OF CONSTRUCTIVE SOLUTIONS, INC. SHALL BE CONSIDERED UNAUTHORIZED AND SHALL RESULT IN THE PARTY MAKING SUCH CHANGES TO OR DEVIATIONS FROM THE DRAWINGS BEING HELD RESPONSIBLE FOR THE CONSEQUENCES RESULTING FROM SUCH CHANGES.1. ALL EXTERIOR WALLS TO BE 2X6 @ 24" ON CENTER U.N.O.2. ALL INTERIOR WALLS TO BE 2X4 @24" ON CENTER U.N.O.3. ALL INTERIOR WALLS TO BE FINISHED WITH 1/2" LWGB U.N.O. SEE PLAN FOR BRACED PANEL OR SHEAR WALL LOCATIONS.4. ALL INTERIOR CEILINGS TO BE FINISHED WITH 1/2" LWGB U.N.O.5. NO DUCTING IN GARAGE.6. GARAGE SHALL HAVE 5/8" TYPE 'X' GWB AT HOUSE COMMON WALLS.7. INSTALL SOUND BATT INSULATION IN WALLS, CEILINGS AND/OR FLOORS PER PLANS.8. ALL CERAMIC TILE TO BE INSTALLED OVER CEMENTITIOUS UNDERLAYMENT BOARD (DUROCK OR EQUIVALENT).9. ALL VENTS, STACKS AND OTHER ROOF PENETRATIONS SHALL BE PAINTED TO MATCH THE ROOFING MATERIAL.10. ALL PLUMBING FIXTURES TO BE OF WATER SAVING TYPE (LOW FLOW, AERATORS, ETC.)11. INSTALL WP GWB TO 4' BEHIND TOILETS AND WP WALL FINISH UP 72" MIN ABOVE FLOOR.12. ALL WINDOWS THERMAL PANE LOW E2 GLAZING. TEMPERED GLAZING AT THE FOLLOWING LOCATIONS: IN GLASS DOORS; GLASS OVER SHOWER OR TUB BELOW 60" FROM STANDING OR WALKING SURFACE; GLASS WITHIN A 24" ARC OF A DOOR; INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET; BOTTOM EDGE LESS THAN 18" ABOVE FLOOR; TOP EDGE GREATER THAN 36" ABOVE THE FLOOR AND ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE GLAZING; ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60" ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE; ADJACENT TO STAIRWAYS WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD.13. CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC.14. "EGRESS" WINDOW DENOTES WINDOW WITH MIN CLEAR WIDTH OF 20", MIN CLEAR HEIGHT OF 22", MIN CLEAR OPENABLE AREA OF 5.7 SQ FT AND FINISHED SILL NOT TO BE MOUNTED MORE THAN 44" ABOVE FLOOR. WINDOW NOTATION CONTAINING A "T" DESIGNATES TEMPERED GLAZING.15. HOUSE TO GARAGE DOOR TO HAVE SELF CLOSING HINGES OR OTHER SELF CLOSING DEVICE16. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, DUCTS ETC. UNLESS SPECIFICALLY NOTED, DETAILED OR APPROVED IN WRITING BY ARCHITECT/ENGINEER.17. VAPOR BARRIERS TO BE MIN 6 MIL THICKNESS AND 1 PERM RATING OR LESS, U.N.O.18. LAG SCREWS, CONSTRUCTION SCREWS AND STRUCTURAL SCREWS TO BE BIG TIMBER CTX "CONSTRUCTION LAG SCREWS" UNLESS SPECIFICALLY CALLED OUT OTHERWISE BY STRUCTURAL ENGINEER, OR WHERE SCREWS ARE SPECIFIED AS PART OF A PROPRIETARY FASTENER SYSTEM (HOLD DOWN, ETC.)19. PROVIDE METAL FLASHING IN SUCH A MANNER AS TO BE LEAK PROOF AT THE FOLLOWING LOCATIONS: (1) THE TOP OF ALL EXTERIOR WINDOW AND DOOR OPENINGS, (2) THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OF STUCCO WALLS, (3) UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS, (4) CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM, (5) WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION, (6) AT WALL AND ROOF INTERSECTIONS, (7) AT BUILT IN GUTTERS.CONSTRUCTION NOTESCONSTRUCTIVE SOLUTIONS, INC COPYRIGHT 2017DRAWN BY:PROJECT #:REVDESCDATEPHASEPRE SDDDCDDATEABCDPO BOX 11529, BOZEMAN, MT 59719406 404-1560 www.constructivesolutionsmt.com24X361/23/2019 12:00:35 PMA0.11/23/19COVER SHEETGILL / LAIRD RESIDENCE310 S. CHURCH AVE.BOZEMAN, MT 59715COA SUBMITTAL----Author--------GILL RESIDENCEBOZEMAN, MONTANAPROJECT TEAMOWNERJAY GILL & LISA LAIRD308 S. CHURCH ST.BOZEMAN, MT 59715ARCHITECTURALCONSTRUCTIVE SOLUTIONS INC1001 W. OAK ST, SUITE 107BOZEMAN, MT 59715406-404-1560 T.406-404-1559 F.CONTACT: MIKE WISEMANARCHITECTURALA0.1 COVER SHEETA1.1 SITE INFORMATIONA3.1 FLOOR PLANSA3.3 ROOF PLANA4.1 EXTERIOR ELEVATIONS