Loading...
HomeMy WebLinkAbout154 BULIDLING PLUMBING SERVICE DETAILS IIACE JOB 22BZ5529 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 Sheet Number: © 2022 Solomon Cordwell Buenz Project Number: Drawn By: Checked By: BULIDLING PLUMBING SERVICE DETAILS II P2.01 2022001.000 Author Checker Tschache Lane & 27 Ave. Bozeman, MT 59718 2695 TSCHACHE LANE NO. DATE DESCRIPTION 08.31.2022 SITE PLAN REVIEW DOCUMENTS A 02.17.2023 SITE PLAN REVIEW - RC 1 M O N T A N A PROFE SSIONA L E N G IN EERLICENSE D T WEEDA KIP A. No. 12615 PE 8/31/2022 F 6 10 P2.00 9 P2.00ELECTRIC WALL HEATER DOMESTIC WATER HEATER DOMESTIC WATER SERVICE FIRE SPRINKLER SERVICE 9 3/4" = 1'-0" CLUBHOUSE WATER RISER ENLARGED PLAN 1 4 F F 9 P2.00 FROM FIRE SPRINKLER SERVICE ENTERENCE. SEE WATER RISER DETAIL 1 FOR COORDINATION. ANGLE STOP VALVE PER CITY OF BOZEMAN REQUIREMENTS WATER METER/STRAINER PROVIDED AND INSTALLED BY THE CITY OF BOZEMAN. REDUCED PRESSURE ZONE ASSEMBLY BACKFLOW PREVENTER. PROVIDE AS WATTS #LF009 OR EQUAL. PIPE DISCHARGE TO FLOOR SINK AND AIR GAP. PRESSURE REDUCING VALVE. PROVIDE AS WATTS #LF223 OR EQUAL. SET DISCHARGE PRESSURE TO 75 PSIG. BUILDING ISOLATION VALVE FIRE SPRINKLER MAIN DRAIN.2" WATER SERVICE FLOOR SINK 3/4" = 1'-0"8 3/4" = 1'-0" CLUBHOUSE WATER RISER DETAIL 25 13 P2.00 ELECTRIC WALL HEATER 12 P2.00 WATER HEATER 3/4" = 1'-0" GEAR GARAGE WATER RISER ENLARGED PLAN 3/4" = 1'-0" 4 A 4 P2.00 3/4" = 1'-0" SINGLE UNIT WATER SERVICE ENLARGED PLAN2 A 1 XP2.00 3/4" = 1'-0"3 SINGLE UNIT WATER SERVICE ENLARGED PLAN 7' - 6"2' - 0"ANGLE STOP PER CITY OF BOZEMAN REQUIREMENTS. PROVIDE WITH ADJACENT SIGN PER NFPA 13D. WATER METER/STRAINER ASSEMBLY PROVIDED AND INSTALLED BY THE CITY OF BOZEMAN 2" COMBINATION WATER/FIRE SERVICE DUAL CHECK BACKFLOW PREVENTER. PROVIDE AS WATTS LF007 OR EQUAL FIRE SYSTEM CONNECTION SEE FIRE SUPPRESSION DRAWINGS FOR COORDINATION. PLUMBING SYSTEM PRESSURE REDUCING VALVE. PROVIDE AS WATTS LF223 OR EQUAL AND SET DISCHARGE PRESSURE TO 75 PSIG PLUMBING SYSTEM ISOLATION VALVE 2'-6" W X 7'-6"L X 2'-0"D VALUT BY PROVIDE WITH LID ACCES FLUSH WIT FINISHED FLOOR. COORDINATE WITH G.C. AS REQUIRED. DOMESTIC WATER UP IN WALL TO PLUMBING SYSTEM WARNING:THE WATER SYSTEM FIRE SPRINKLERS THAT REQUI PRESSURES TO FIGHT A FIRE. DE FLOW OR DECREASE THE PRESS SHUT OFF THE WATER TO THE SUCH AS WATER SOFTENERS, F AUTOMATIC SHUTOFF VALVES THIS SYSTEM WITHOUT A REVI SYSTEM BY A FIRE PROTECTIO REMOVE TH *SIGN SHALL BE PROVIDED WITH BE AFFIXED ADJACENT TO THE 3/4" = 1'-0" SINGLE UNIT WATER SERVICE DETAIL5 7' - 6"2' - 0"ANGLE STOP PER CITY OF BOZEMAN REQUIREMENTS. WATER METER/STRAINER ASSEMBLY PROVIDED AND INSTALLED BY THE CITY OF BOZEMAN 1" DOMESTIC WATER SERVICE DUAL CHECK BACKFLOW PREVENTER. PROVIDE AS WATTS LF007 OR EQUAL PLUMBING SYSTEM PRESSURE REDUCING VALVE. PROVIDE AS WATTS LF223 OR EQUAL AND SET DISCHARGE PRESSURE TO 75 PSIG PLUMBING SYSTEM ISOLATION VALVE 2'-6" W X 7'-6"L X 2'-0"D VALUT BY G.C. PROVIDE WITH LID ACCES FLUSH WITH FINISHED FLOOR. COORDINATE WITH G.C. AS REQUIRED. DOMESTIC WATER UP IN WALL TO PLUMBING SYSTEM 3/4" = 1'-0"1 SINGLE UNIT WATER SERVICE DETAIL FIRE SPRINKLER SERVICE. SEE FIRE PROTECTION DRAWINGS FOR COORDINATION. FIRE SPRINKLER MAIN DRAIN. 3/4" = 1'-0" GEAR GARAGE FIRE RISER DETAIL6 ANGLE STOP VALVE PER CITY OF BOZEMAN REQUIREMENTS WATER METER/STRAINER PROVIDED AND INSTALLED BY THE CITY OF BOZEMAN. REDUCED PRESSURE ZONE ASSEMBLY BACKFLOW PREVENTER. PROVIDE AS WATTS #LF009 OR EQUAL. PIPE DISCHARGE TO FLOOR SINK AND AIR GAP. PRESSURE REDUCING VALVE. PROVIDE AS WATTS #LF223 OR EQUAL. SET DISCHARGE PRESSURE TO 75 PSIG. BUILDING ISOLATION VALVE 1 1/2" WATER SERVICE FLOOR SINK 3/4" = 1'-0" GEAR GARAGE WATER RISER DETAIL7 1 4 10 P2.00 DOMESTIC WATER SERVICE SEE WATER RISER DETAIL 2 FOR COORDINATION. FIRE SPRINKLER SERVICE. SEE FIRE PROTECTION DRAWINGS FOR COORDIANTION. SEE WATER RISER DETAIL 2 FOR CONTINUATION 3/4" = 1'-0" CLUBHOUSE WATER RISER DETAIL 13 2 4 5 6 7 8 7 8 5 6