Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
153 BULIDLING PLUMBING SERVICE DETAILS I
ACE JOB 22BZ5529 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 Sheet Number: © 2022 Solomon Cordwell Buenz Project Number: Drawn By: Checked By: BUILDING PLUMBING SERVICE DETAILS l P2.00 2022001.000 Author Checker Tschache Lane & 27 Ave. Bozeman, MT 59718 2695 TSCHACHE LANE NO. DATE DESCRIPTION 08.31.2022 SITE PLAN REVIEW DOCUMENTS A 02.17.2023 SITE PLAN REVIEW - RC 1 M O N T A N A PROFE SSIONA L E N G IN EERLICENSE D T WEEDA KIP A. No. 12615 PE 8/31/2022 6 P2.00 7 P2.00 UNIT HEATER. SEE MECHANICAL FOR COORDINATION FIRE SUPPRESSION SERVICE. SEE FIRE SUPPRESSION PLANS FOR COORDINATION DOMESTIC WATER SERVICE. SEE WATER SERVICE RISER DETAIL FOR COORDINATION. MANUAL WET STANDPIPE FIRE DEPARTMENT CONNECTION AUTOMATIC SPRINKLER FIRE DEPRATMENT CONNECTION FIRE SPRINKLER MAIN DRAIN 6"ø FP-WET 4"ø CW4"ø CW 3/4" = 1'-0" FLATS WATER RISER ROOM ENLARGED PLAN6 Level 1 0' -0" GATE VALVE PER CITY OF BOZEMAN REQUIREMENTS. PROVIDE THURUST BLOCKING AND RESTRAINT AS REQUIRED. WATER METER/STRAINER PROVIDED AND INSTALLED BY THE CITY OF BOZEMAN. 18" SPOOL UPSTREAM AND DOWNSTREAM OF WATER METER REDUCED PRESSURE BACKFLOW PREVENTER. PIPE DISCHARGE TO FLOOR SINK AND AIR GAP. PROVIDE AS WATTS #M400-OSY OR EQUAL. PRESSURE REDUCING VALVE. PROVIDE AS WATTS #LF115-74 OR EQUAL AND SET DISCHARGE TO 75 PSIG. BUILDING ISOLATION VALVE 4" DOMESTIC WATER TO BUILDING FROM FIRE SERVICE TO FDC. SEE FIRE PROTECTION DRAWINGS FOR COORDINATION FDC AUTO-SPRINK FIRE SPRINKLER MAIN DRAIN. SEE FIRE PROTECTION DRAWINGS FOR COORDINATION FLOOR SINK NOT TO SCALE FLATS WATER RISER DETAIL1 8 2 P2.00 3/4" = 1'-0"1 ROWHOME WATER SERVICE ROOM ENLARGED PLAN Level 1 0' -0" FIRE SPRINKLER SERVICE; SHOWN FOR REFERENCE ONLY. SEE FIRE PROTECTION PLANS FOR COORDINATION. ELECTRIC UNIT HEATER; SHOWN FOR REFERENCE ONLY. SEE MECHANICAL PLANS FOR COORDINATION 1 1/2" DOMESTIC COLD WATER SERVICE. SEE UNDERFLOOR PLANS FOR COORDINATION. ANGLE STOP VALVE PER CITY OF BOZEMAN REQUIREMENTS WATER METER/STRAINER PROVIDED AND INSTALLED BY THE CITY OF BOZEMAN. REDUCED PRESSURE ZONE ASSEMBLY BACKFLOW PREVENTER. PROVIDE AS WATTS #LF009 OR EQUAL. PIPE DISCHARGE TO FLOOR SINK AND AIR GAP. PRESSURE REDUCING VALVE. PROVIDE AS WATTS #LF223 OR EQUAL. SET DISCHARGE PRESSURE TO 75 PSIG. BUILDING ISOLATION VALVE UNIT ISOLATION VALVES. MANIFOLD AS REQUIRED TO SERVE INDIVIDUAL DWELLING UNITS 1" COLD WATER TO EACH UNIT (2 OR 4). SEE UNDERFLOOR PLANS FOR COORDINAITON WASTE PIPE CLEANOUT 3/4" = 1'-0" ROWHOME WATER RISER DETAIL3 Level 1 0' -0" FIRE SPRINKLER SERVICE. SEE FIRE PROTECTION DRAWINGS FOR COORDINATION ELECTRIC WALL HEATER. SEE MECHANICAL FOR COORDINATION. 3/4" = 1'-0" FLATS FIRE RISER DETAIL2 1 2 3 4 2 3 4