Loading...
HomeMy WebLinkAbout150 PLUMBING COVER SHEETPLUMBING SYMBOLS LEGEND PIPING FITTINGS, VALVES & SPECIALTIES GENERAL PIPING MISCELLANEOUS/MECHANICAL PIPING TYPES VTR M M or or or or or or or or or or or or FT P1P-1 GLOBE VALVE 3-WAY (ELECTRIC) THIS IS A STANDARDIZED SYMBOLS LEGEND, ALL SYMBOLS SHOWN MAY NOT APPEAR ON OR WITHIN THIS SET OF CONTRACT DOCUMENTS. VENT THRU ROOF STRAINER W/ BLOW-OFF 3-WAY (PNEU. MTR.) 3-WAY (PNEUMATIC) PRESSURE GAUGE TEMP. GAUGE SENSOR (TEMP./FLOW) FLEX. CONNECTION SOLENOID GATE VALVE WALL HYDRANT OR HOSE BIBB FLOAT VALVE BALANCING VALVE DRAIN PLUG VALVE CHECK VALVE PRESS. REDUCING 2-WAY (ELECTRIC) 2-WAY (PNEU. MTR.) 2-WAY (SOLENOID) PNEUMATIC MOTOR ANGLE VALVE EXIST. FIXTURE TO REMAIN EXIST. FIXT. TO BE REMOVEDNEW PLUMBING FIXTURE FIXT. NUMBER -SEE SCHED. GATE VALVE BALL VALVE CROSS IN HORIZ. RUN 90° AND 45° ELBOWS END CAP CONNECTION BELL AND SPIGOT UNION FITTING BRANCH TEE TURNED UP BRANCH TEE TURNED DN. DIRECTION OF FLOW ELBOW TURNED DN. TEE TURNED DN. DROP IN HORIZ. RUN TEE TURNED UP ELBOW TURNED UP REDUCER FITTING TEE IN HORIZ. RUN BRANCH TEE W/ OFFSET PUMP FIRE EXTINGUISHER FIRE SPRINKLER HEAD DISCONNECTION P.O.D.C. -POINT OF P.O.C. -POINT OF CONNECTION DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRC. CONDENSATE DRAIN NATURAL GAS BUTTERFLY VALVE SANITARY WASTE STORM DRAINAGE -PRIMARY VENT G CD HWRC HW CW V SD SAN PIPING PHASE EXISTING PIPING NEW ABOVE FLOOR PIPING TEMPORARY PIPING DEMOLISHED PIPINGNEW UNDERFLOOR PIPING STORM DRAINAGE -OVERFLOWSD-0F or STRAINER FIRE PROTECTION WETF-WET FIRE PROTECTION DRYF-DRY or HWRC HW CW V SD SAN PIPING PHASE SD-0F NOTES: 1. FIREPLACE RING, GAS ORFICE, ELECTRONIC VALVE, AND PILOT PROVIDED BY OTHER AND INSTALLED BY PLUMBING CONTRACTOR. 2. FIREPLACE ENCLOSURE PROVIDED BY OTHER. COORDINATE WITH ENCLOSURE CONSTRUCTION WITH PIPING AND ACCESS REQUIREMENTS. 3. ALL PIPING, KEY VALVE, SOLINOID VALVE, AND ISOLATION VALVE PROVIDED BY PLUMBING CONTRACTOR. 4. WIRE SOLINOID VALVE TO SUPERVISORY CONTROL SYSTEM OR EMERGENCY SHUTOFF AS INDICATED. SEE PLUMBING DRAWINGS AND ELECTRICAL DRAWINGS FOR COORDINATION 5. INSTALL ALL FIREPLACE COMPONENTS PER MANUFACTURER RECOMMENDATION. ISOLATION VALVE ANODLESS RISER PE BURIED GAS PIPE; 18" MINIMUM BURY DEPTH SEE DRAWINGS FOR SIZE AND LOCATION ANODLESS RISER GROUND 3/4" CSST GAS PIPING POWER CONDUIT; SEE ELECTRICAL FOR COORDINATION KEY VALVE WITH CHROME COVER STAINLESS STEEL FLAT PAN FIRE RING MANUFACTURED ENCLOSURE BY OTHER ELECTRONIC IGNITION GAS VALVE SOLINOID VALVE NOTE: GAS REGULATOR PROVIDED AT METER ASSEMBLY. GAS PRESSURE SHALL BE 14" W.C. TO GAS METER/REGULATOR CONTROL CONDUIT POWER CONDUIT; SEE ELECTRICAL FOR COORDINATION CONTROL CONDUIT SUPERVISORY CONTROLLER OR EMERGENCY OFF SWITCH. SEE SCHEDULE AND DRAWIGNS FOR COORDINATION. NOTES: 1. BBQ EQUIPMENT, GAS ORFICE, ELECTRONIC VALVE, AND PILOT PROVIDED BY OTHER AND INSTALLED BY PLUMBING CONTRACTOR. 2. BASE CABINET PROVIDED BY OTHER. COORDINATE BASE CABINET CONSTRUCTION WITH PIPING AND ACCESS REQUIREMENTS. 3. ALL PIPING, BALL VALVE, SOLINOID VALVE, AND ISOLATION VALVE PROVIDED BY PLUMBING CONTRACTOR. 4. WIRE SOLINOID VALVE TO SUPERVISORY CONTROL SYSTEM OR EMERGENCY SHUTOFF AS INDICATED. SEE PLUMBING DRAWINGS AND ELECTRICAL DRAWINGS FOR COORDINATION 5. INSTALL ALL FIREPLACE COMPONENTS PER MANUFACTURER RECOMMENDATION. ISOLATION VALVE ANODLESS RISER PE BURIED GAS PIPE; 18" MINIMUM BURY DEPTH SEE DRAWINGS FOR SIZE AND LOCATION ANODLESS RISER GROUND NOTE: GAS REGULATOR PROVIDED AT METER ASSEMBLY. GAS PRESSURE SHALL BE 14" W.C. TO GAS METER/REGULATOR POWER CONDUIT; SEE ELECTRICAL FOR COORDINATION CONTROL CONDUIT SUPERVISORY CONTROLLER OR EMERGENCY OFF SWITCH. SEE SCHEDULE AND DRAWIGNS FOR COORDINATION. OUTDOOR BBQ EQUIPMENT BALL VALVE SOLINOID VALVE 5/8" CSST PIPE TO BURNER MANIFOLD ADJACENT BASE CABINET 4.5" W.C. GAS REGULATOR CONTROL CONDUIT ACE JOB 22BZ5529 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 Sheet Number: © 2022 Solomon Cordwell Buenz Project Number: Drawn By:Checked By: PLUMBING COVER SHEET P0.00 2022001.000 Author Checker Tschache Lane & 27 Ave. Bozeman, MT 59718 2695 TSCHACHE LANE PLUMBING SHEET LIST NUMBER NAME P0.01 PLUMBING SCHEDULES & DETAILS P0.31 PLUMBING SITE PLAN P2.00 BUILDING PLUMBING SERVICE DETAILS l NOT TO SCALE1OUTDOOR FIRE PIT CONNECTION DETAIL NOT TO SCALE2OUTDOOR BBQ GAS CONNECTION DETAIL NO. DATE DESCRIPTION 08.31.2022 SITE PLAN REVIEW DOCUMENTS A 02.17.2023 SITE PLAN REVIEW - RC 1 M O N T A N A PROFE SSIONA L E N G IN EERLICENSE D T WEEDA KIP A. No. 12615 PE 8/31/2022