Loading...
HomeMy WebLinkAbout086 SITE SIGNAGE & PAVEMENT MARKINGSGENERAL NOTES:1.IN GENERAL, EXISTING STRUCTURES AND FACILITIES ARE NOTED AS "EXISTING" AND ARE SHOWN IN LIGHT LINE WEIGHTS ORAS SCREENED BACKGROUND. NEW STRUCTURES OR FACILITIES ARE SHOWN IN HEAVY LINE WEIGHTS.2.PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ONTHE DRAWINGS. THE CONTRACTOR SHALL BE COME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETETHE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID.3.GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARDPRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NCSA BYTELEPHONE AT 301-215-4521 OR ON-LINE AT WWW.NECA-NEIS.ORG.4.THE CONTRACTOR SHALL NOTIFY THE MONTANA ONE CALL CENTER @ 811 OR (800) 551-8344 FOR ON-SITE UTILITY LOCATION.ALL KNOWN EXISTING UTILITIES SHALL BE MARKED BEFORE DIGGING.5.CONTRACTOR SHALL HAVE APPROVAL FROM ALL GOVERNING AGENCIES HAVING JURISDICTION OVER ANY UTILITY SYSTEMPRIOR TO INSTALLATION.CONSTRUCTION NOTES:1.THE LOCATION, DEPTH, AND SIZE OF EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTORSHALL FIELD VERIFY THE EXISTENCE, LOCATION, DEPTH, SIZE, LINE AND GRADE OF EXISTING UTILITY CONNECTIONS PRIORTO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUETO FAILURE TO LOCATE OR PROVIDE PROPER PROTECTION WHEN LOCATION IS KNOWN.2.LOCATION OF SITE UTILITIES SHALL BE VERIFIED BY CONTRACTOR AND THE UTILITY COMPANY PROVIDING SERVICE. ANYPROPOSED ADJUSTMENTS TO DRY UTILITY LOCATION SHALL BE COORDINATED WITH UTILITY COMPANIES.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITHNORTHWESTERN ENERGY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OFNORTHWESTERN ENERGY WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES AREMET.4.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKSSTANDARD SPECIFICATIONS, SEVENTH EDITION DATED APRIL 2021 (MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THEMPWSS; AND THE PROJECT SPECIFICATIONS.5.CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE DIVISION OF INDUSTRIAL REGULATIONS (OSHA) SAFETY STANDARDS. IFREQUESTED BY THE INSPECTOR, THE CONTRACTOR SHALL PROVIDE PROOF OF A PERMIT FROM SAID DIVISION.6.THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED WITHIN THE PROJECT LIMITS. MATERIALS AND EQUIPMENT SHALL BESTORED ON THE PROJECT SITE WHERE APPROVED BY THE OWNER. IT SHALL BE UNDERSTOOD THAT THE RESPONSIBILITYFOR PROTECTION AND SAFEKEEPING OF EQUIPMENT AND MATERIALS ON OR NEAR THE SITE WILL BE ENTIRELY THAT OFTHE CONTRACTOR AND THAT NO CLAIM SHALL BE MADE AGAINST THE OWNER BY REASON OF ANY ACT OF AN EMPLOYEE ORTRESPASSER.7.CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND ARE TO BEBROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO COMMENCEMENT OR CONTINUATION OF CONSTRUCTION ACTIVITIES.8.REFERENCE ALL SURVEY MONUMENTS, SECTION CORNERS, 1/4 CORNERS, AND PROPERTY CORNERS PRIOR TO BEINGDISTURBED BY CONSTRUCTION. ANY MONUMENTS AND CORNERS DISTURBED DURING CONSTRUCTION SHALL BE REPLACEDBY A PROFESSIONAL LAND SURVEYOR (PLS) REGISTERED IN THE STATE OF MONTANA.9.A PRE-CONSTRUCTION MEETING (AS REQUIRED) SHALL BE HELD WITH THE GENERAL CONTRACTOR, SITESUBCONTRACTOR,CITY OF BOZEMAN, OWNER, AND MORRISON-MAIERLE, INC. PRIOR TO THE START OF CONSTRUCTION.10.THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE CITY, COUNTY, AND/OR STATE INSPECTOR 48 HOURS PRIOR TOCOMMENCING CONSTRUCTION AND 24 HOURS IN ADVANCE OF SPECIFIC INSPECTION NEEDS DURING THE COURSE OF THEWORK. ALL WORK SHALL BE PERFORMED DURING NORMAL WORKING HOURS AND SUBJECT TO THE AVAILABILITY OF ANINSPECTOR AND APPROVED BY THE ENGINEER. THE CONTRACTOR WILL BE BILLED FOR SAID INSPECTION SERVICES ASPROVIDED IN THE MOST RECENTLY ADOPTED FEES FOR SUCH SERVICES.11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL PUBLIC AND PRIVATE PROPERTY INSOFAR AS IT MAY BEAFFECTED BY THESE OPERATIONS, ALL COSTS FOR PROTECTING, REMOVING, AND RESTORING EXISTING IMPROVEMENTSSHALL BE BORNE SOLELY BY THE CONTRACTOR.12.THE CONTRACTOR SHALL IMMEDIATELY CLEAN UP ANY CONSTRUCTION MATERIALS INADVERTENTLY DEPOSITED ONEXISTING STREETS, SIDEWALKS, OR OTHER PUBLIC RIGHTS-OF-WAY AND MAKE SURE STREETS AND WALKWAYS ARECLEANED AT THE END OF EACH WORKING DAY.13.CONSTRUCTION WORK ZONE TRAFFIC SIGNS SHALL BE FURNISHED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITHAPPLICABLE REQUIREMENTS OF THE REGULATORY AGENCIES HAVING JURISDICTION. A TRAFFIC CONTROL PLAN, PREPAREDBY THE CONTRACTOR, MAY BE REQUIRED BY THE CITY OR STATE. "CONSTRUCTION AHEAD" WARNING SIGNS ARE TO TO BEINSTALLED ALONG ADJACENT ROADS OR DRIVEWAYS. FLASHERS WITH CAUTION TAPE ARE TO BE INSTALLED WHERE ANYCONSTRUCTION ACTIVITY CROSSES A SIDEWALK OR PEDESTRIAN PATH IN ACCORDANCE WITH THE SPECIFICATIONS ANDANY OR ALL LOCAL REGULATIONS.14.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TOEXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/OR ENGINEER.15.THE CONTRACTOR SHALL UTILIZE COMPACTION EQUIPMENT SUITABLE FOR THE SOIL TYPES AND SURFACE MATERIALSENCOUNTERED ON THE PROJECT.16.CONTRACTOR IS RESPONSIBLE FOR PROJECT DUST CONTROL.Know what'sbelow.before you dig.CallRINCOMING ELECTRICAL SERVICEDIVISION OF RESPONSIBILITYELEC.CONTR.UTILITYCO.PRIMARY CONDUITXPRIMARY CONDUCTORSXPOLE MOUNTTRANSFORMERXPOLE RISERXTRANSFORMERCONNECTIONSXSECONDARY CONDUITXSECONDARYCONDUCTORSXDISCONNECTXMETER BASEXMETERXNOTES:1. CONTACT AND COORDINATE ALL REQUIREMENTS AND RESPONSIBILITIES WITH SERVING UTILITY COMPANIES PRIOR TO SUBMITTING BID2. ALL SERVICE INSTALLATION WORK SHALL BE IN STRICT COMPLIANCE WITH THE REQUIREMENTS OF THE SERVING UTILITIES.MORRISON MAIERLE, INC. HAS CONTACTED THE UTILITIES BUT HAS NOT RECEIVED INWRITING THE FINAL REQUIREMENTS FROM THE POWER UTILITY.THESE DRAWINGS INDICATE OUR BEST ESTIMATION OF THEIR REQUIREMENTS. PRIOR TOBID CONTACT THE UTILITIES AND OBTAIN IN WRITING THEIR REQUIREMENTS.ELECTRICAL SYMBOL LEGENDSYMBOLDESCRIPTIONSMOUNTINGHEIGHT, UNOBRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH CIRCUITS AS NOTED. WIRESIZE IS #12 UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONGTICK MARKS INDICATE NEUTRAL CONDUCTORS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOREACH 120V BRANCH CIRCUIT. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDEDWITH EACH HOME RUN.RACEWAY BELOW FLOOR OR BELOW GRADERACWAY STUB-OUT OR STUB-UP WITH BUSHED ENDPAD MOUNTED TRANSFORMERUTILITY ELECTRIC METER SEE DETAIL 2/E0.3.METERLINE BREAKHANDHOLE SEE DETAIL 6/E0.2KEY NOTE. REFER TO SPECIFIC NOTE ON SAME DRAWING SHEET.POLE MOUNTED LUMINAIRE ASSEMBLY SECURED TO CONCRETE BASE. LETTER INDICATES FIXTURETYPE.PHOTOCELLDUPLEX RECEPTACLE.18"SPECIAL PURPOSE OUTLET, LETTER INDICATES TYPE. SEE SPEC.18"JUNCTION BOXFUSED DISCONNECT SWITCHBRANCH CIRCUIT PANELBOARD BREAKERCONTACTOR1. THESE SYMBOLS COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.2. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR. MOUNTING HEIGHTSINDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGSOR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.P-1,3,5MMHH1PAJCABBREVIATIONSA or AMPAMPERESACALTERNATING CURRENTA/CAIR CONDITIONINGAFAMP FUSEAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEALALUMINUMASAMP SWITCHBASBUILDING AUTOMATION SYSTEMBKRBREAKERCRACEWAY/CONDUITCBCIRCUIT BREAKERCCTVCLOSED CIRCUIT TELEVISIONCKTCIRCUITC.O.RACEWAY/CONDUIT ONLY, WITH PULL STRINGCNTRLCONTROLCUCOPPERDISCDISCONNECTDISTDISTRIBUTIONDPDTDOUBLE POLE DOUBLE THROWDWGDRAWINGEAEACHEFEXHAUST FANELECELECTRICEMTELECTRICAL METALLIC TUBINGEQUIPEQUIPMENTEX OREXISTEXISTINGFDFUSED DISCONNECTFLRFLOORFOFIBER OPTICFVNRFULL VOLTAGE NON-REVERSINGFVRFULL VOLTAGE REVERSINGGECGROUNDED ELECTRODE CONDUCTORGFIGROUND FALUT INTERRUPTERGNDGROUNDGRCGALVANIZED RIGID CONDUITHIDHIGH INTENSITY DISCHARGEHOAHAND-OFF-AUTOMATICHPHORSEPOWERHPSHIGH PRESSURE SODIUMHTRHEATERHZHERTZJ-BOXJUNCTION BOXKVAKILOVOLT AMPERESKWKILOWATTSLTGLIGHTINGMAXMAXIMUMMHMETAL HALIDEMINMINIMUMNNEUTRALNCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODENEMANATIONAL ELECTRICAL MANUFACTURERSASSOCIATIONNFDNON-FUSED DISCONNECTNICNOT IN CONTRACTNONORMALLY OPEN#NUMBEROCON CENTEROHOVERHEADPPOLEPBPUSHBUTTONPNLPANELPVCPOLYVINYL CHLORIDE CONDUITPWRPOWERRECEPTRECEPTACLERGSRIGID GALVANIZED STEELRMROOMRVNRREDUCED VOLTAGE NON-REVERSINGRVRREDUCED VOLTAGE REVERSINGSPSINGLE POLE TOGGLE SWITCHSPECSPECIFICATIONSPSTSINGLE POLE SINGLE THROWSSPBSTART-STOP PUSHBUTTONSWSWITCHTCTIME CLOCKTDTIME DELAYTSPTWISTED SHIELDED PAIRTTBTELEPHONE TERMINAL BOARDTYPTYPICALUGUNDERGROUNDUHUNIT HEATERUNOUNLESS NOTED OTHERWISEUONUNLESS OTHERWISE NOTEDVVOLTVAVOLT AMPERESWWATTSWPWEATHERPROOFW/OWITHOUTXFMRTRANSFORMERYWYE CONNECTEDDELTA CONNECTEDPHASE*THESE ABBREVIATIONS COMPRISE A STANDARD LIST;NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.ELECTRICAL NOTES& ABBREVIATIONSCCFWEHC13-1SheetNumber:© 2022 Solomon Cordwell BuenzProjectNumber:Drawn By:Checked By:Tschache Lane & 27 Ave.Bozeman, MT 597182695 Tschache Lane2022001.000NO.DATEDESCRIPTIONSITE PLAN REVIEW - RC 102.17.2023ASITE PLAN REVIEW SUBMISSION08.31.20224SITE PLAN REVIEW - RC 205.10.2023BSITE PLAN RC-2 05/2023