Loading...
HomeMy WebLinkAbout035 IRRIGATION PLANLOT 4PROPOSED BUILDINGFOOTPRINT = 4,929 SFW BABCOCK ST.STAFFORD AVE.LOT 4PROPOSED BUILDINGFOOTPRINT = 4,929 SFLOT 4PROPOSED BUILDINGFOOTPRINT = 4,929 SFIRRIGATION POINT OF CONNECTIONROOM 134SEE P201C930 SF1 - D1"QUICK COUPLERZONE 1ZONE 14.192 - T1"ZONE 1121212121212121212121212121288888888888888888886.723 - T1"3504 - D1"ZONE 43506 - D1"ZONE 6612 SF5 - D1"ZONE 5ZONE 5ZONE 5ZONE 6ZONE 6ZONE 5WEATHER STATIONMOUNT ON STRUCTUREEXISTING IRRIGATION TO REMAIN - NOT IN SCOPEEXISTING IRRIGATION TO REMAIN - NOT IN SCOPEEXISTING IRRIGATION TO REMAIN - NOT IN SCOPEEXISTING IRRIGATION TO REMAIN - NOT IN SCOPEIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIGATION LEGENDCQCWSIRRIGATION NOTES1.SEE SPECIFICATION 328400 'PLANTING IRRIGATION' FOR MORE INFORMATION.2.CONTRACTOR TO DESIGN IRRIGATION SYSTEM PER SCHEMATIC LAYOUTAND INSTALL UNDERGROUND AUTOMATIC IRRIGATION SYSTEM TO PROVIDEADEQUATE WATER FOR ALL PLANT MATERIAL AS SHOWN ON DRAWINGS.INSTALL MANUAL DRAINS AT LOW POINTS AND AIR RELIEF VALVES AT HIGHPOINTS ALONG MAINLINE. INSTALL QUICK COUPLERS AT END OF MAINLINEAND ISOLATION VALVES DOWNSTREAM OF MAINLINE TEES.3.IRRIGATION SYSTEM TO BE INSTALLED TO PREVENT OVER-SPRAY ONTOBUILDING AND PAVED SURFACES.4.THE PLAN IS DIAGRAMMATIC FOR PIPING. ADJUST PIPE LOCATION ASNECESSARY. ALL VALVES & PIPING ARE TO BE INSTALLED IN PLANTING ORMULCH AREAS.5.DO NOT INSTALL THE IRRIGATION SYSTEM WHEN OBVIOUS OBSTRUCTIONS,GRADE CHANGES OR OTHER DETRIMENTAL SITE GEOMETRY EXISTS.6.ALL INFORMATION SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TOCONSTRUCTION.7.CONTRACTOR SHALL COORDINATE WATER CONNECTIONS AND IRRIGATIONCONTROLLER WITH OWNER'S REPRESENTATIVE. CONTRACTOR SHALLCONFIRM WATER SOURCE FOR PRESSURE AND GPM REQUIREMENTS PRIORTO CONSTRUCTION THROUGH SUBMITTALS.8.IN THE EVENT OF ANY DISCREPANCIES, NOTIFY THE OWNER'SREPRESENTATIVE IMMEDIATELY.9.PROPOSED TREES, SHRUBS, AND PERENNIALS SHALL BE WATERED BYPOINT SOURCE DRIPLINE WITH DRIP ZONE CONTROL KIT AS DETAILED ANDNOTED ON LEGEND. PROVIDE PVC LATERALS TO BEDS AND CONNECT TO PEPIPE AS DETAILED, SPECIFIED AND SHOWN ON PLAN.10.CONTRACTOR SHALL PROVIDE SLEEVING FOR PIPE BELOW PAVEMENT.SLEEVE AS SPECIFIED. SUPPLY ONE EXTRA SLEEVE WITH EACH MAINLINESLEEVE FOR CONTROL WIRES. COORDINATE SLEEVE INSTALLATION WITHOTHER TRADES AND OTHER PROJECTS. BORE UNDER EXISTING PAVEDAREAS AS REQUIRED USING DRILL, AUGER, WATER JET, OR ANY OTHERINSTRUMENT APPROVED BY OWNER'S REPRESENTATIVE CAPABLE OFPRODUCING A PRECISE HOLE. BORING SHALL NOT DISTURB OVERLAYINGSTRUCTURES OR CAUSE SETTLEMENT AND DAMAGE TO THOSESTRUCTURES. IF DEMOLISHING EXISTING PAVEMENT FOR SLEEVEINSTALLATION, PATCH EXISTING ASPHALT AS REQUIRED.11.IRRIGATION SYSTEM SHALL BE INSTALLED IN STRICT ACCORDANCE WITHALL PERTINENT CODES AND REGULATIONS, THE REFERENCED STANDARDS,AND THE MANUFACTURER'S RECOMMENDATIONS.12.PROVIDE ALL COMPONENTS REQUIRED FOR PROPER WINTERIZATION OFSYSTEM.13.LINE SIZE WINTERIZATION BLOW-OUT ADAPTER SHALL BE INSTALLEDIMMEDIATELY DOWN STREAM OF POINT OF CONNECTION.14.LATERAL LINES SHALL BE SOLVENT WELDED CL200 PVC PIPE.15.ELECTRICAL & MANUAL GATE VALVES SHALL BE INSTALLED IN VALVE BOXESOR APPROVED EQUAL. USE A 12" STANDARD BOX FOR ALL CONTROLVALVES. 10" ROUND FOR ALL OTHERS.16.PROVIDE VALVE BOX EXTENSIONS AS REQUIRED.17.ALL WIRES SHALL BE INSTALLED UNDER A MINIMUM OF 12" COVER AND MAYBE INSTALLED IN TRENCHES WITH PIPE AS LONG AS THE WIRES AREINSTALLED UNDER THE PIPE.18.DBY DRY SPLICE WIRE CONNECTORS SHALL BE USED FOR ALL ELECTRICALCONNECTIONS.19.ADD AIR RELIEF VALVE PER DETAIL AT HIGHEST POINT IN THE IRRIGATIONSYSTEM.DESCRIPTIONDETAILSHEETWATER POINT OF CONNECTION1L401NEW MAIN LINE, 1" SCH 40 PVC2L401LATERAL LINE, 1" CLASS 200 PVC IPS PLASTIC PIPE2L401SLEEVE SCH 40 PVC, 2X LINE SIZE3L401ISOLATION VALVE AS SPECIFIED5L401DRIP CONTROL VALVE AS SPECIFIED7L401ELECTRIC CONTROL VALVE AS SPECIFIED9L401QUICK COUPLER AS SPECIFIED11L401DRIP ZONE, INLINE DRIP TUBING OR DRIP TUBINGWITH POINT SOURCE EMITTERS, AS SPECIFIED FLOW: 2 GPH TREES 1 GPH SHRUBS 0.5 GPH PERENNIALS EMITTER SPACING: PER PLANT LAYOUT12 & 13L401SPRINKLER HEADS AS SPECIFIED, NOZZLES: 8'-12' HUNTER MPR 100014L401TRADITIONAL CONTROLLER AS SPECIFIED16L401WEATHER STATION AS SPECIFIED17L401SYMBOLIRRGALLONS PER MINUTE (GPM)VALVE SIZE (D- INDICATES PLANT BED DRIP) 9.5 GPM3 - D1.5"ZONE CALLOUT:STATION /ZONE (T- INDICATES TURF) VEGETATION TYPESFWATER REQUIREMENTIRRIGATION TYPEGAL/MONTHTURF1310MEDIUMMPR SPRAY HEADS1729TREES,SHRUBS &PERENNIALS2242LOWDRIP - PRESS COMP5598TOTAL35527327IRRIGATION USE BY VEGETATION TYPE:ZONESFVEGETATION TYPEZONE 1930SHRUBS, PERENNIALSZONE 2525TURFZONE 3785TURFZONE 4350SHRUBS, PERENNIALSZONE 5612TREES, NATIVE GRASSESZONE 6350TREES, SHRUBS, PERENNIALSTOTAL3552IRRIGATION AREA BY ZONE:DRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®BHHS BOZEMAN OFFICE BERKSHIRE HATHAWAY HOME SERVICESCONSTRUCTION DOCUMENTS03.27.202320235/25/2023 4:26 PM | L:\BERKH_BZN\BIMCAD\LandArch\BERKH_BZN_L400.dwgL400IRRIGATIONPLAN-1L400IRRIGATION PLANNORTH051020SCALE: 1" = 10'7.001