Loading...
HomeMy WebLinkAbout023 ROOF PLAN1 A301 ______________ 2 A301 ______________ 5 B 61234 A C D E F 23'-6" 1/4" / 1'-0"1/4" / 1'-0" 1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"RIDGERIDGERIDGERD OFRD RD OFRD RD OFRD RD OFRD EF VTR RH 1 1 8 8 TYP. 7 2 TYP. 3 51 A111 1 A111 1 A111 1 A111 1 A1111 A111 2 A111 2 A111 2 A112 2 A112 ROOF PLAN GENERAL NOTES 1. PREFINISHED METAL PARAPET CAP -REFER TO DETAIL 1/A111. 2. 1/2":12" TAPERED POLYISOCYANURATE CRICKET - TYPICAL. 3. PRIMARY ROOF DRAIN (RD) AND OVERFLOW ROOF DRAIN (OFRD) -REFER TO DETAILS 7/A111 AND 8/A111. 4. ROOFTOP MECHANICAL UNIT (RTU) -REFER TO DETAIL 4/A111. 5. ROOF ACCESS HATCH -INSTALL ROOF HATCH PER DETAIL 3/A111 AND INSTALL ACCESS LADDER PER DETAIL 10/A111. 6. NOT USED. 7. EXHAUST FAN CURB -REFER TO DETAIL 5/A111. 8. VENT PIPE THROUGH ROOF (VTR) AND RTU PIPE PENETRATION THROUGH ROOF -FLASH PER DETAIL 9/A111. #KEYED NOTES A. SEE STRUCTURAL FRAMING PLAN FOR ROOF DECK HEIGHTS TO ESTABLISH ROOF SLOPES AND ROOF MEMBER LOCATIONS. B. COORDINATE W/ ELECTRICAL, MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION ON ROOF PENETRATIONS. C. ALL FINISHED ROOF SLOPES TO ACHIEVE A MINIMUM OF 1/4" PER FOOT SLOPE IN THE DIRECTION INDICATED. IT IS THE RESPONSIBILITY OF THE ROOFING CONTRACTOR TO INSTALL ROOFING COMPONENTS TO MEET THESE REQUIREMENTS. D. PROVIDE WALKING PADS AS INDICATED ON PLAN TO ACCESS MECHANICAL EQUIPMENT. E. PREFABRICATED CURBS SHALL BE INSTALLED AND SET LEVEL. F. CONSTRUCTION SHALL BE IN FULL COMPLIANCE WITH ALL CURRENT LOCAL CODES AND REGULATION IN EFFECT AT THE TIME OF AGREEMENT BETWEEN OWNER AND CONTRACTOR. G. PAINT ALL EXPOSED FERROUS METAL PER SPECIFICATIONS DIVISION 9 'EXTERIOR PAINTING'. H. IN NO CASE SHALL CONSTRUCTION RELATED WORK BE DONE, OVER, OR CONSTRUCTION RELATED TRAFFIC BE ROUTED OVER FINISHED ROOF AREAS OR ROOF SECTIONS WITHOUT PROTECTION BEING PLACED OVER ROOF MEMBRANE. ALL ROOF AREAS OR ROOF SECTIONS THAT HAVE ROOF RELATED WORK IS REQUIRED TO HAVE ROOF PROTECTION PLACED OVER ROOF MEMBRANE. NOTE: DAMAGED ROOF AREAS THAT HAVE NOT BEEN PROTECTED FROM CONSTRUCTION RELATED TRAFFIC SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. REVISIONS 5/26/2023 1:45:46 PM ROOF PLAN A110 03.31.2023 © 2023 | ALL RIGHTS RESERVED CONSTRUCTION DOCUMENTS BHHS BOZEMAN OFFICEBERKSHIRE HATHAWAY HOME SERVICES | Project# BERKH_BZN | L:\ PROJ# | BERKH_BZN DESIGNED BY | TOPP DRAWN BY | JONES REVIEWED BY | LAST NAME 3/16" = 1'-0"A110 1 ROOF PLAN NORTH REF