Loading...
HomeMy WebLinkAbout008 COVER SHEETDRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®BHHS BOZEMAN OFFICE BERKSHIRE HATHAWAY HOME SERVICESSITE PLAN SUBMITTAL03.24.202320235/25/2023 4:44 PM | L:\BERKH_BZN\BIMCAD\Civil\Plans\BERKH_BZN_C000.dwgC000COVER SHEET1 05.22.2023 CITY COMMENTSBERKSHIRE HATHAWAY HOME SERVICES BHHS BOZEMAN OFFICEBLOCK 1, LOT 4, VALLEY WEST SUBDIVISIONPROPERTY OWNER/APPLICANTKardar, LLC2001 Stadium Dr.Bozeman, MT 59715406.558.7704ARCHITECT / ENGINEERCushing Terrell411 E Main StSuite #101Bozeman, MT 59715406.556.7100APPLICATION DATA:ZONING: B-1 NEIGHBORHOOD BUSINESS DISTRICTCURRENT LAND USE: VACANTCOMMUNITY PLAN: COMMUNITY COMMERCIAL MIXED USEDNEIGHBORHOOD CONSERVATION: NOHISTORIC DISTRICT: NOLEGAL DESCRIPTION:LOT 4, BLOCK 1, AMENDED PLAT OF TRACT 3AM AMENDED PLAT OF THE REMAINDER OFTRACT 3, BLOCK 1, VALLEY WEST SUBDIVISIONPARCEL SIZE: 13,585 SF = 0.31 ACRESSITE DESCRIPTION:SITE / BUILDING DATA:WETLAND/WATERCOURSE: NOFLOOD ZONE: NOT IN FLOOD ZONEPROPOSED LAND USE:ADDRESS: STAFFORD AVE BOZEMAN, MT 59715AFFORDABLE HOUSING: NOT BEING PROVIDED WITH THIS PROJECTSITE STATISTICS(USING NET)=100%13,585 SF PERCENTAGE OF BUILDINGS =36.3%4,929 SFPERCENTAGE OF DRIVES AND PARKING =0%0 SF.PERCENTAGE OF SETBACKS, O.S. & LANDSCAPE =63.7% 8,656 SFBUILDING INFORMATION EXISTING (FAR) PROPOSED GROSS (FAR) PROPOSED NET (85%)FLOOR TO SITE RATIO (FAR) BUILDING/ STRUCTURE 0 SF (0.00) 9,858 SF(0.726)8,379 SFPOWER AND GAS SERVICEUTILITY CONTACTSTELEPHONECENTURY LINK502 S 19TH AVEBOZEMAN, MT 59715FIBER OPTICCHARTER1500 N 19TH AVEBOZEMAN, MT 59715PUBLIC WATER SUPPLYPROJECT LOCATIONADDRESS: 15 STAFFORD AVEBOZEMAN, MT 59718LAND USE MAPLocatorZONING MAPBLOCK FRONTAGE MAPNORTHNORTHNORTHNORTHTO THE BEST OF MY KNOWLEDGE THE FACILITIES PROVIDEDMEET ALL OF THE MINIMUM ACCESSIBILITY REQUIREMENTSACCEPTED BY: _____________________________ ___________ CITY ENGINEER DATEACCEPTED BY: _____________________________ ___________PROFESSIONAL ENGINEER DATEADA CERTIFICATION SIGNATURE BLOCKPROJECTAREAPROJECTAREAR-MHB-1R-OB-2R-0R-3EXISTING CHURCHRESIDENTIALRESIDENTIALCOMMERCIALVACANTNORTHWESTERN ENERGY121 E. Griffin DrBozeman, MT 59715406.223.9730CITY OF BOZEMAN814 N. Bozeman StreetBozeman, MT 59715406.582.3200CIVILXXC000COVER PAGEXC001GENERAL NOTES & LEGENDXC100OVERALL SITE PLANXXC101ENLARGED SITE PLANXC200OVERALL GRADING & DRAINAGE PLANXXC201ENLARGED GRADING & DRAINAGE PLANXXC300OVERALL UTILITY PLANXXC301ENLARGED UTILITY PLANXC400CIVIL DETAILSXC401CIVIL DETAILS05.22.2023 SITE PLAN RESUBMITTAL 03.24.2023 SITE PLAN SUBMITTAL LANDSCAPEXXL101LANDSCAPE PLANXXL201LANDSCAPE DETAILSXL301PLANTING PLANXL400IRRIGATION PLANXL401IRRIGATION DETAILSARCHITECTUREXXG100ZONING CODE REVIEWXXA101FIRST LEVEL FLOOR PLANXXA102SECOND LEVEL FLOOR PLANXA110ROOF PLANXXA201EXTERIOR ELEVATIONSXXA202EXTERIOR ELEVATIONSELECTRICALXE100ELECTRICAL SITE PLANXEP100PHOTOMETRIC PLANPROJECTAREAMIXEDMIXEDMIXEDLANDSCAPEREQUIREDPER THE MASTER SITE PLAN FOR THIS DEVELOPMENT:1 PARKING SPACE PER 400 SF = 21 SPACES20% ALLOWABLE REDUCTION FOR OFFICES IN NEIGHBORHOOD COMMERCIAL (B-1) = 17 SPACES (16 NON-ACCESSIBLE + 1 ACCESSIBLE)BIKE SPACES = 2MAXIMUM PARKING ALLOWED (125%) = 21 X 1.25 = 26PROVIDEDSTANDARD SPACES = 20 EXISTING OFF STREETADA SPACES = 1 EXISTINGTOTAL SPACE PROVIDED = 17 EXISTINGTOTAL BIKE SPACES PROVIDED = 10 NEWPARKING DATA:112021 IBC BASIC DESIGN CRITERIADESIGN LIVE LOADINGIBC TABLE 1607.1DECK LIVE LOADING (SNOW) 46 psf.SNOW LOADASCE 7 TABLE 7.2-4 FOR MONTANAGROUND SNOW LOAD 46 psf.ROOF SNOW LOAD 41 psf.ARM 24.301.146 (23) SUBSECTION 1608.2 IS DELETED - "SNOW LOADSFOR STRUCTURAL DESIGN IN MONTANA", CIVIL ENGINEERINGDEPARTMENT, MONTANA STATE UNIVERSITY, 2004 REVISED EDITION.IBC SECTION 1507.1.2 ICE BARRIER REQUIREDFROST DEPTHONE STORY 36" MINIMUM TO BOTTOM OF FOOTINGTWO STORY 48" MINIMUM TO BOTTOM OF FOOTINGBASIC DESIGN WIND SPEED (3-SECOND GUST)WIND SPEED = 115 mph.USING IBC FIGURES 1609.3(1) 1609.3(2) 1609.3(3) AND 1609.3(4)EXPOSURE CATEGORY PER IBC SECTION 1609.4.SEISMIC DESIGN CATEGORY: D1.DETERMINE THE MAPPED MAXIMUM CONSIDERED EARTHQUAKESPECTRAL RESPONSE ACCELERATION AT SHORT PERIODS (Ss) ANDAT 1-SECOND PERIOD (S1), FOR THE SITE LOCATION FROM IBCFIGURES 1623.2.3(1) THROUGH 1623.2.3(2) RESPECTIVELY.2.DETERMINE THE (SOIL) SITE CLASS IN ACCORDANCE WITH ASCE 7.3.DETERMINE SITE COEFFICIENTS (Fa) AND (Fv) FROM IBC TABLES1613.2.3(1) AND 1613.2.3(2) RESPECTIVELY.4.DETERMINE THE 5-PERCENT DAMPED DESIGN SPECTRAL RESPONSEACCELERATION AT SHORT PERIODS (Sds) AS FOLLOWS:Sds = (2/3) (Sms)Sd1 = (2/3) (Sm1)5.DETERMINE THE SEISMIC DESIGN CATEGORY AS PRESCRIBED BYTABLES 1613.2.5(1) AND 1613.2.5(2). THE HIGHEST OF THE SEISMICDESIGN CATEGORIES FROM THE TWO TABLES IS THE ONE ASSIGNED.GEOTECHNICAL (SOILS)SITE SPECIFIC GEO TECHNICAL ANALYSIS REQUIRED AT PERMITAPPLICATION.FINAL OBSERVATION REPORT SUBMITTED PRIOR TO FOOTINGINSPECTION.COMMERCIAL PROJECTS2021 INTERNATIONAL BUILDING CODE (IBC)ARM RULE 24.301.1462021 INTERNATIONAL MECHANICAL CODE (IMC)ARM RULE 24.301.1722021 INTERNATIONAL FUEL GAS CODE (IFGC)ARM RULE 24.301.1732021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)ARM RULE 24.301.161ICC A117.1-2017 STANDARD FOR ACCESSIBLE AND USABLEBUILDINGS AND FACILITIESARM SUBCHAPTER 24.301.92021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)ARM RULE 24.301.1712020 NATIONAL ELECTRIC CODE (NEC)ARM RULE 24.301.4012021 UNIFORM PLUMBING CODE (UPC) (IAPMO)ARM RULE 24.301.3012021 INTERNATIONALSWIMMING POOL AND SPA CODEARM RULE 24.301.1752012 INTERNATIONAL FIRE CODEARM RULE 23.12.601OTHER RELATED ARM RULESSUBCHAPTER 24.301.6 ELEVATORS, ESCALATORS. AND MOVING WALKSSUBCHAPTER 24.301.7 BOILER SAFETYDESIGN CRITERIA (CITY OF BOZEMAN ADOPTED):STATE OF MONTANA -ADOPTED CODES:11