HomeMy WebLinkAboutGarage ADU_APA Shear Wall CalcSTORY 1 STORY 2 APA Wall Bracing Calculator Project Report Builder/Designer Miller Design Build, LLC Home/Building Plan Name Sherman Garage ADU Development Address 116 S. 11th Ave Bozeman, MT 59715 Code BASED ON 2021 IRC SDC (Seismic Design Category)D0 Wind Speed <= 115 mph Wind Exposure Category EXPOSURE B Total Number of Stories 2 STORY Cripple Wall NO Mean Roof Height less than 30 ft.YES Designer Responsibilities: Check irregularities per IRC section R301.2.2.6 Confirm load path to foundation per IRC section R403.1.6 Design foundations per IRC section R403.1 Include interior braced wall line foundations per IRC Section R602.11 Design cripple walls in one of two ways Redesignate as the first story and use the calculator Design by hand per IRC Section R602.10.10. A B1 2 A B1 2 B1 B1 WALL LINE ELEVATION VIEW Total Wall Line Length: 15' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 1st Story A CS-WSP 0.81 6.08 0.85 4.08 6.08 15 Compliant Furthest Distance to Adjacent BWL 24' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 15' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 15' 0"15 6"/12" When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B1 B2 WALL LINE ELEVATION VIEW Total Wall Line Length: 15' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 1st Story B CS-PF 0.81 6.08 0.85 4.08 6.08 6.83 Compliant Furthest Distance to Adjacent BWL 24' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 15' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-PF 2' 10"7' 0"2.83 3"/3" grid 1,000 B2 8'9'CS-WSP 4' 0"7' 0"4 6"/12" Include proper PF or ABW details on the plans. When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B3 B1 B2 B3 WALL LINE ELEVATION VIEW Total Wall Line Length: 24' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 1st Story 1 CS-WSP 0.81 4.05 0.85 6.53 6.53 15.92 Compliant Furthest Distance to Adjacent BWL 15' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 24' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 1' 8"6' 8"0 6"/12" B2 8'9'CS-WSP 3' 2"6' 8"3.17 6"/12"1,800 B3 8'9'CS-WSP 12' 9"6' 8"12.75 6"/12"1,800 Include proper HD details for IRC placement rules on the plans. When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B3 B1 B2 B3 WALL LINE ELEVATION VIEW Total Wall Line Length: 24' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 1st Story 2 CS-WSP 0.81 4.05 0.85 6.53 6.53 18 Compliant Furthest Distance to Adjacent BWL 15' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 24' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 3' 0"3' 0"3 6"/12" B2 8'9'CS-WSP 9' 5"3' 0"9.42 6"/12" B3 8'9'CS-WSP 5' 7"3' 0"5.58 6"/12" When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B1 B2 WALL LINE ELEVATION VIEW Total Wall Line Length: 15' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 2nd Story A CS-WSP 0.66 2.57 0.85 2 2.57 10 Compliant Furthest Distance to Adjacent BWL 24' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 15' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 5' 0"2' 0"5 6"/12" B2 8'9'CS-WSP 5' 0"2' 0"5 6"/12"1,800 Include proper HD details for IRC placement rules on the plans. When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B3 B1 B2 B3 WALL LINE ELEVATION VIEW Total Wall Line Length: 15' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 2nd Story B CS-WSP 0.66 2.57 0.85 2 2.57 5.34 Compliant Furthest Distance to Adjacent BWL 24' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 15' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 0' 7"4' 0"0 6"/12" B2 8'9'CS-WSP 2' 8"5' 0"2.67 6"/12"1,800 B3 8'9'CS-WSP 2' 8"5' 0"2.67 6"/12"1,800 Include proper HD details for IRC placement rules on the plans. When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B3 B1 B2 B3 WALL LINE ELEVATION VIEW Total Wall Line Length: 24' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 2nd Story 1 CS-WSP 0.66 1.82 0.85 3.14 3.14 9.83 Compliant Furthest Distance to Adjacent BWL 15' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 24' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 6' 0"8' 0"6 6"/12" B2 8'9'CS-PF 3' 10"8' 0"3.83 3"/3" grid 1,000 2,475 B3 8'9'CS-WSP 0' 5"7' 0"0 6"/12" Include proper PF or ABW details on the plans. Include proper HD details for IRC placement rules on the plans. When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. B1 B2 B3 B4 B5 B1 B2 B3 B4 B5 WALL LINE ELEVATION VIEW Total Wall Line Length: 24' 0" WALL LINE PLAN VIEW Story WallLine BracingMethod WindFactors Wind BracingAmount SeismicFactors Seismic BracingAmount RequiredBracing QualifiedBracing BracingStatus 2nd Story 2 CS-WSP 0.66 1.82 0.85 3.14 3.14 9.92 Compliant Furthest Distance to Adjacent BWL 15' 0"Stone or Masonry Veneer Omitted Roof Eave to Ridge Height 5 feet Wall Dead Load <= 8 psf Wall Line Length 24' 0"Roof/Ceiling Dead Loads <= 15 psf Gypsum Included Blocking Included Wall Line Segment Wall Height Story Height Bracing Method Segment Length Adjacent OpeningHeight Qualified Segment Nails Tension Tie Hold Down B1 8'9'CS-WSP 3' 0"4' 0"3 6"/12" B2 8'9'CS-WSP 4' 11"4' 0"4.92 6"/12" B3 8'9'CS-WSP 2' 5"6' 8"0 6"/12" B4 8'9'CS-PF 2' 0"6' 8"2 3"/3" grid 1,000 2,475 B5 8'9'CS-WSP 0' 7"4' 0"0 6"/12" Include proper PF or ABW details on the plans. Include proper HD details for IRC placement rules on the plans. When SDC C Townhouse and D0-D2 are selected, check that irregularities in R301.2.2.2.5 are evaluated. Sherman Garage ADU | 116 S. 11th Ave Bozeman, MT 59715 | BASED ON 2021 IRC APA Wall Bracing Calculator v2.7.0 APA Makes No Warranties of Any KindAll information in the Tool is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, andwithout warranty of any kind, express or implied, including, but not limited to warranties of performance, merchantability and fitness for a particular purpose.You canfind the full terms and conditions for use here: https://www.apawood.org/apa-wall-bracing-calculator-disclaimer