Loading...
HomeMy WebLinkAboutC1.3DrainagePlan EXT'G 8"pp STORMTECH ADS RgTENTION/ N N N M W W W..WTR MAIN (DRIVEWAY INFILTRATION BASIN ACCEPTABLE FILL MATERIALS: STORMTECH CHAMBER SYSTEMS N N N N _ 7 ROWS OF 5 SC-740 CHAMBERS a \ 7�7 EXT'G 8"PVC SAS SWR 10' PUE BOTTOM OF INFILTRATOR 4696.5 AASHTO MATERIAL COMPACTION /DENSITY p N N o\ RENEE WAY G. ELEC.RED. XT'G FENC BOTTOM OF GRAVEL 4694.9 MATERIAL LOCATION DESCRIPTION CLASSIFICATIONS REQUIREMENT (PRIVATE) 5 SI EWALK EXT'G FENCE RNAL FRL:RLL MA1EMAl Tat uYElt b' ANY SOIL OCK MATERIALS,NATIVE FR REQUIREMENT m M NT _ roARR1S iAQI TXf TOP Oi 11E'C uYER /R ENp�f 11 Mx^TpA�Eb m CURB INLET EeoTnx+a RElmIE PA-T SOILS,OR PER ENGINEER'S PLANS. >TG. OMM PED D e Rxsxm cgnce rams. N/A / TBC 4699.94 CHECK PLANS FOR PAVEMENT p1RINmIMATEMnL AND POA xDF TMEnOEMFNT SUBBASE MnY SUBGRADE REQUIREMENTS. REWP.m Z 12" PVC SO - _ 12 INV OUT 4696.44 b uTEq ¢ m I SCALE GRANULAR WELL-GRADED G AASHTO M145• BEA N C011PAo�ignWix[whams•(s��OgEmAw)En\� S=D.S% IZ STARUTSRFApPILL TIE ippTEA�FIg1ER'C A-1.A-2-4.A-3 p \\ SOIL/AGGREGATE MIXTURES,t35S CpAP�C ADoi7gWAN evos i��s•0.mm) L= 0 b EUBmMaT STM('B'wyER)m 1x• FINES OR PROCESSED AGGREGATE. OR - �- 12" PVC SD 9 G (w00raem�xoiE Tx'"ni nTTH°F:"f PnvE n raq°"pngncwTE 3 ` CURB INLET - SIIBB SE w.Y EE A PART a THE'c' MOST PAVEMENT SUBBASE AASHTO M43' 1RxN5.q°u[R DRoss vwpa xaWT Q Q Q W I S=1.2% 12" PVC SO uyE MATERIALS CAN BE USED IN UM OF 3,357,4,467,5,56,57,6, x°T ro Excm012,a°o ms(v Mu).OYNAxC w TBC 47DO.25 1 _ _ ]IpCll� 3D• THIS LAYER. 67,68,7,78,S.89.9,10 FARCE xOT To Exam 2°,am ie•(ee xx) g g 4 EXISTING12" I L= 10 S-1.0% m m m I 12" INV THRU 4697.25 _ L- 52' o�RmMENT smxE:Ru SU-NwxG > >> z SPRUCE,18"di.. �� -m r 111E CHAMBERS FROM THE FOUNDAbON AASHTO M43• 0 00 J B ('n'uTEn)ro THE'C uTER CLEAN,CRUSHED,ANGULAR STONE x0 COMPACTW gEWP:m. W w w 36" DIA SDMH ABm4. 4,487,5.56,57 Of Of o' o- o RIM 4700.10 AASHTO M43' PLATE CgAPACT OR ROLL TO O FauuD nax smxc Ru efLow Z w w w I - = NYLOPLAST DRAIN BASIN S INV THRU 4696.85 A arMaERs m°M THE WSwAa:UP TD CLEAN.CRUSHED.ANGULAR STONE 3,357.4.467.5.56.57 AONLYE A FIAT mRFAa.•• ~ ~~ ~ 1NE iWT(1-)OR THE CHAMBER. RIM 4700.2 w Of Of o' o- 12" INV THRU 4696.35 12" PVC SD D' 000w - - - - - - - - - w, ,1 - - S=1.40% PLEASE NOTE: W w o_ 24 DIA) 36" DIA SDMH L= 45' 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN,CRUSHED, ANGULAR. 0 0 0 0 1 AREA DRAIN RIM 4701.5 FOR EXAMPLE, A SPECIFICATION FOR#4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4(AASHTO M43) - 0 0 v) I I INV THRU 4697.1 CURB INLET STONE". w w w w _ SD TBC 4700.48 EXTG ELEC _ '� 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A'LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6' RED. 12' INV THRU 4697.48 (150 Tim)(MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 1 I L \ 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A Z J 12" PVC SD FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD - - - - s S=0.93% DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. 4 L= 62' I F •� 12" PVC SD XpO NTq Nq 12". I L= 23 CHRIS G. h I I ADS L E ALL AROUND 6 LE NON-WOVENGEOTEXTILE ALL AROUND CLEAN, CRUSHED, eu°Esxi N{ L ANGULAR STONE IN A&B LAYS FINISH GRADE 8' MAX " o.iGazs PE 8" PVC ROOF DRAIN " VDRAN 1 .4 PIPING. 5=1.0%TO PERIMETER STONE xP )NA�E� I CONNECT DOWNSPOUTS ` EXT'G UTILITY (SEE NOTE 6)� ,w,� """ Fw uxvA ROOF DRAIN PIPING (TYP) i I POLE ---- - -- --C - Gm.R.Mrnua mTmm24T01.•(=.mi T �18' M Nx _ _ _ - - - - - N K r� EXCAVATION WALL DRAWN BY: CGB o Y'" CURB INLET 9' DEPTH OF STONE r-- \ _ (CAN BE SLOPED TBC NV TH 5 OR VERTICAL) REVIEWED BY: EWR EXT'G ELEC FINISH FLOOR 12' INV THRU 4698.05 ' \ ° ' DEPTH OF STONE _ PROJECT ENGINEER:CGB PED. ELEVATION I I __ �-�746-��12' SC-740 SUBGRADE SOILS ADESIGNED BY:CGB - - - - - - - I4702.5 - r 12' MIN 6' MIN ' 12" PVC SD o /III� 5=1.0% (SEE NOTE 4) (~ L= 91 NOTES: i 1. CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418"STANDARD SPECIFICATION FOR POLYPROPYLENE(PP)CORRUGATED WALL STORMWATER EXT'G ELEC ��1•A COLLECTION CHAMBERS", OR ASTM F2922"STANDARD SPECIFICATION FOR POLYETHYLENE(PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". CIO I 11�CC•`•1' L.� METER 2.CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787"STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". a EXTG ELEC 6 3."ACCEPTABLE FILL MATERIALS"TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, ICI ^ O D. - - -° l CURB INLET EMBEDMENT, AND FILL MATERIALS. Z F� /N� TBC 4701.95 W 12" INV OUT 4698.95 4.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE(ALLOWABLE BEARING CAPACITY)OF THE SUBGRADE SOILS AND THE /1 I DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. L•( AREA 4D RAIN / �� 1 / 5.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. Fa 24" DIA 6.ONCE LAYER 'C'IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D'UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO ExYc ELEC I AREA DRAIN O ^ ley - RED. � / \ I � REPLACE THE MATERIAL REQUIREMENTS OF LAYER'C'OR'D'AT THE SITE DESIGN ENGINEER'S DISCRETION. � z CONCRETE O A I U.G. PARKING L TEL. � L4 1 OT �ETAIL \ ADS MC-3500 STORMTECH-TYPICAL DETAIL PED NTS N EX N "\ OUTLEEXT'G ELEC w�\ INLAND FOUNDRY#772 CAST IRON 4" I FRAME AND GRATE.�h I ASTM CLASS O RAY IRON _ P OBSERVATION PORT PER ADS SPEC �q M TOPSOIL AND INLAND FOUNDRY 772 CAST LANDSCAPING W 8" PVC ROOF DRAIN c IRON 4"FRAME AND GRATE. [[[777]]] .. W - - - - PIPING. S=1.0% w I I I CONSOLIDATED PERIMETER VARIES Oty 00 CONNECT DOWNSPOUTS TO GRADE RINGS-2"MIN STONE PER ADS 18' MIN h+•1 n ROOF DRAIN PIPING (TYP) FINISH FLOOR \ III I I I SPECIFICATIONS(TYP) 9' ELEVATION 24"DIA. REINFORCED H�j I i, •,I \ / I CONCRETE PIPE HIGH CAPACITY INFILTRATOR 4704.25 c / ADS- STORMTECH SC-740 V 24 DIA - - `� 24 DIA MANUFACTURED TO ASTM C-76 30 `r ," .•� 3 AREA DRAIN\ \ AREA DRAIN- // / „� 6' MIN BETWEEN 46 12' MIN z�y TEL COMM I I IJI C BASINS I _ _ _ INSTALL FREE DRAINING ROCK K GAS MARKER J BOX _ _ _ _ _J \\ RKER POST �-24' FROM BOTTOM OF INFILTRATOR TO �' 1 �. �19' MIN SSMH - -- - _ r j-' 12"INTO EXTG GRAVEL LAYER. - N O RGST I IS - � ' � ' z o StlD SVD Stl0 /6'SIDEWALK GEOTECHNICAL ENGINEER SHALL • BE ON-SITE DURING EXCAVATION _ ® V 00 Un TO VERIFY FREE DRAINING GRAVEL T, _ \ MATERIAL DEPTH. (7a S*N`lTARY SEWER CLEANOUT i 3 9' SUMP ° ` EXT'G STREET 6"BASE SLAB AS EXTG NATIVE__--- Q0 LIGHT a SECONDARY POUR EXT'G STREET EXTG CURB 64 GRAVEL LAYER NOTE LIGHT &GUTTER EXT'G CONCRETE CONTRACTOR TO a DRIVEWAY GROUT OPENING. INSTALL PER STORMTECH S S SS S S SPECIFICATIONS r PIPE O.D.+3' 3 SHEET 24"AC SAN SWR MAIN SAN SWR MH � 6"MIN COMPACTED 3 DETAIL _ w w W GRANULAR BEDDING C13 ADS MSC-740 STORMTECH-PROJECT SPECIFIC DETAIL C1.3 BAXTER LANE 12"DI WATER MAIN COMPACTED SUBGRADE NTS UPLAND WAY o Sal DETAIL o DRAINAGE PLAN o H OHE OHE OHE C13 36"DIA.STORM SEWERMANHOLE PROJECT:20-112 NTS a DATE:09/30/21