Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43 L1 LIGHTING BY MORRISON MAIERLE_Part1
VERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!THIS RECORD DRAWING HAS BEENPREPARED, IN PART, BYINFORMATION PROVIDED BYOTHERS. THE ENGINEER HAS NOTVERIFIED THE ACCURACY AND / ORCOMPLETENESS OF THISINFORMATION IN ALL INSTANCESAND SHALL NOT BE RESPONSIBLEFOR ANY ERRORS OR OMISSIONSTHAT MAY BE INCORPORATED ASA RESULT OF INFORMATIONPROVIDED BY OTHERS.2020engineers surveyors planners scientistsMorrisonMaierleCOPYRIGHT © MORRISON-MAIERLE, INC.,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYN:\2286\009\ACAD\RECORD\AS-BUILT PLANS\BOUND CAD FILES\2ND HALF\E-LIGHTING SHEETS.DWG PLOTTED BY:CODY FARLEY ON Jul/27/2020REVISIONSDRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:ENGINEER:P.E. NO.:DATE:RECORD DRAWING NOTE2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netNELSON MEADOWS2286.008BOZEMANMONTANAELECTRICAL DETAILSL-1ARGARGARG2/19RJH2/191CITY REVIEW05/17/2019CPKAMY GALT30605PE02/20192RECORD DRAWINGS07/08/2020CJF LUMINAIRE SCHEDULESYMBOLTYPELAMPSDESCRIPTIONSMANUFACTURERCATALOG NO. OR SERIESMOUNTING/VOLTAGEE190W LEDPOLELIGHT WITH TYPE III DISTRIBUTION W/ FULL CUTOFF OPTICS AND 7-PIN RECEPTACLE. MOUNTON 30FT ROUND TAPERED POLE ON CONCRETE BASE WITH 6FT ARM. PROVIDE HUNTER GREENFINISH (RAL#6005) PER CITY OF BOZEMAN STANDARDS. PROVIDE ARM AND POLE PER CITY OFBOZEMAN STANDARDS.PHILIPS LUMECFIXTURE:RFM-90W40LED3K-G2-LE3F-DMG5-240-RCD7POLE/240E250W LEDPOLELIGHT WITH TYPE II DISTRIBUTION W/ FULL CUTOFF OPTICS AND 7-PIN RECEPTACLE. MOUNTON 25FT ROUND TAPERED POLE ON CONCRETE BASE WITH 6FT ARM. PROVIDE ARM AND POLEPER CITY OF BOZEMAN STANDARDS.PHILIPS LUMECFIXTURE:RFM-50W40LED3K-G2-LE2F-DMG5-240-RCD7POLE/240ELECTRICAL SYMBOL LEGENDSYMBOLDESCRIPTIONSMOUNTINGHEIGHT, UNOBRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH CIRCUITS AS NOTED. WIRESIZE IS #12 UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONGTICK MARKS INDICATE NEUTRAL CONDUCTORS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOREACH 120V BRANCH CIRCUIT. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDEDWITH EACH HOME RUN.RACEWAY BELOW FLOOR OR BELOW GRADERACWAY STUB-OUT OR STUB-UP WITH BUSHED ENDPAD MOUNTED TRANSFORMERUTILITY ELECTRIC METERMETERLINE BREAKHANDHOLE SEE DETAIL 1/L-2KEY NOTE. REFER TO SPECIFIC NOTE ON SAME DRAWING SHEET.POLE MOUNTED LUMINAIRE ASSEMBLY SECURED TO CONCRETE BASE. LETTER INDICATES FIXTURETYPE.PHOTOCELLDUPLEX RECEPTACLE.18"JUNCTION BOXFUSED DISCONNECT SWITCHBRANCH CIRCUIT PANELBOARDBREAKERCONTACTOR1. THESE SYMBOLS COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.2. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR. MOUNTING HEIGHTSINDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGSOR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.P-1,3,5MMHH1PJCABBREVIATIONSA or AMPAMPERESACALTERNATING CURRENTA/CAIR CONDITIONINGAFAMP FUSEAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEALALUMINUMASAMP SWITCHBASBUILDING AUTOMATION SYSTEMBKRBREAKERCRACEWAY/CONDUITCBCIRCUIT BREAKERCCTVCLOSED CIRCUIT TELEVISIONCKTCIRCUITC.O.RACEWAY/CONDUIT ONLY, WITH PULL STRINGCNTRLCONTROLCUCOPPERDISCDISCONNECTDISTDISTRIBUTIONDPDTDOUBLE POLE DOUBLE THROWDWGDRAWINGEAEACHEFEXHAUST FANELECELECTRICEMTELECTRICAL METALLIC TUBINGEQUIPEQUIPMENTEX OREXISTEXISTINGFDFUSED DISCONNECTFLRFLOORFOFIBER OPTICFVNRFULL VOLTAGE NON-REVERSINGFVRFULL VOLTAGE REVERSINGGECGROUNDED ELECTRODE CONDUCTORGFIGROUND FALUT INTERRUPTERGNDGROUNDGRCGALVANIZED RIGID CONDUITHIDHIGH INTENSITY DISCHARGEHOAHAND-OFF-AUTOMATICHPHORSEPOWERHPSHIGH PRESSURE SODIUMHTRHEATERHZHERTZJ-BOXJUNCTION BOXKVAKILOVOLT AMPERESKWKILOWATTSLTGLIGHTINGMAXMAXIMUMMHMETAL HALIDEMINMINIMUMNNEUTRALNCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODENEMANATIONAL ELECTRICAL MANUFACTURERSASSOCIATIONNFDNON-FUSED DISCONNECTNICNOT IN CONTRACTNONORMALLY OPEN#NUMBEROCON CENTEROHOVERHEADPPOLEPBPUSHBUTTONPNLPANELPVCPOLYVINYL CHLORIDE CONDUITPWRPOWERRECEPTRECEPTACLERGSRIGID GALVANIZED STEELRMROOMRVNRREDUCED VOLTAGE NON-REVERSINGRVRREDUCED VOLTAGE REVERSINGSPSINGLE POLE TOGGLE SWITCHSPECSPECIFICATIONSPSTSINGLE POLE SINGLE THROWSSPBSTART-STOP PUSHBUTTONSWSWITCHTCTIME CLOCKTDTIME DELAYTSPTWISTED SHIELDED PAIRTTBTELEPHONE TERMINAL BOARDTYPTYPICALUGUNDERGROUNDUHUNIT HEATERUNOUNLESS NOTED OTHERWISEUONUNLESS OTHERWISE NOTEDVVOLTVAVOLT AMPERESWWATTSWPWEATHERPROOFW/OWITHOUTXFMRTRANSFORMERYWYE CONNECTEDDELTA CONNECTEDPHASE*THESE ABBREVIATIONS COMPRISE A STANDARD LIST;NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.1.PRIOR TO BID CONTRACTOR SHALL VISIT THE SITES. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT ISSHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORKREQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THEBID.2.GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1,"STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION ISAVAILABLE FROM NCSA BY TELEPHONE AT 301-215-4521 OR ON-LINE AT WWW.NECA-NEIS.ORG.3.U.N.O. ALL POLES AND METER BASES SHALL BE LOCATED 3' FROM BACK OF CURB. VERIFY ALL STATION NUMBERSAND COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS PRIOR TO ROUGH-IN.4.ALL NEW POLES SHOULD BE PROVIDED WITH BREAKAWAY BOLTS PER MDT REQUIREMENTS. PROVIDE TRANSPOPOLE-SAFE MODEL 4100 OR EQUAL.5.CONTRACTOR TO IMMEDIATELY NOTIFY ENGINEER AND OWNER OF ANY CONFLICTS ENCOUNTERED DURINGCONSTRUCTION. UNDER NO CIRCUMSTANCES SHALL CONTRACTOR RESOLVE CONFLICT PRIOR TO NOTIFICATION.PROJECT NOTESELECTRICAL SPECIFICATIONSRACEWAY:·MINIMUM RACEWAY SIZE: 1"-INCH TRADE SIZE.OUTDOORS:·EXPOSED CONDUIT: RIGID STEEL CONDUIT.·CONCEALED CONDUIT, ABOVE GROUND: EMT.·UNDERGROUND CONDUIT: RNC, TYP EPC-40-PVC, DIRECT BURIED. USE TYPEEPC-80-PVC UNDER PAVED SURFACES.·BOXES AND ENCLOSURES, ABOVE GROUND: NEMA250, TYPE 3R.CONDUCTORS:·ALL CONDUCTORS IN RACEWAY: TYPE THHN-THWN, SINGLE CONDUCTORS.·COPPER. SOLID FOR NO. 10 AWG AND SMALLER, STRANDED FOR NO. 8 AWGAND LARGER.·CONCEALED IN NEW CEILINGS AND WALLS: TYPE THHN-THWN, SINGLECONDUCTORS.METERING:·COMPLY WITH REQUIREMENTS OF UTILITIES PROVIDING ELECTRICAL POWERSERVICES.·COORDINATE INSTALLATION AND CONNECTION OF UTILITIES AND SERVICES,INCLUDING PROVISION FOR ELECTRICITY-METERING COMPONENTS.·METERS WILL BE FURNISHED BY UTILITY COMPANY.·CURRENT-TRANSFORMER CABINETS: COMPLY WITH REQUIREMENTS OFELECTRICAL-POWER UTILITY COMPANY.·METER SOCKETS: COMPLY WITH REQUIREMENTS OF ELECTRICAL-POWERUTILITY COMPANY.·COMPLY WITH EQUIPMENT INSTALLATION REQUIREMENTS IN NECA 1.·INSTALL RACEWAYS AND EQUIPMENT ACCORDING TO UTILITY COMPANY'SWRITTEN REQUIREMENTS. PROVIDE EMPTY CONDUITS FOR METERINGLEADS AND EXTEND GROUNDING CONNECTIONS AS REQUIRED BY UTILITYCOMPANY.RECORDDRAWINGS07/08/2020