026.2 THIRD, FOURTH FLOOR & ROOF PLANS - BUILDING 7
DWDWDWDWDWDWDWDWUPUPDNDNSTAIR AE301CORRIDORE302STAIR BE303STORAGEE304UNIT 1BR-1U7301UNIT 2BR-1U7302UNIT 1BR-3U7303UNIT 1BR-3U7304UNIT 1BR-3 VAR. 1U7305UNIT 1BR-3 VAR. 1U7306UNIT 1BR-4U7307UNIT 2BR-3U7308A4.44A4.42A4.41A4.43W03W03W02W02W02W02W02W03W02W02W02W02W02W02W02W02W02W02W02W02W02W02W02A9.12SIMSIMA9.125' - 0"20' - 10"21' - 8"5' - 0"25' - 10 5/8"26' - 7 3/8"52' - 6"6' - 10"14' - 2 3/4"6' - 6"7' - 5 1/4"11' - 8"15' - 6"9' - 2"8' - 2"13' - 1 3/4"7' - 6"4' - 6 3/4"4' - 6 7/8"10' - 5 5/8"11' - 8"7' - 10"27' - 6 3/4"43' - 9 1/4"28' - 9 3/4"9' - 1 5/8"29' - 11 5/8"139' - 3"21' - 7 3/4"6' - 2 3/8"21' - 7 3/8"5' - 3 3/8"39' - 0"30' - 0"30' - 1 1/4"39' - 1 1/4"37' - 7 1/2"30' - 0"30' - 1 1/4"26' - 6 1/8"6' - 10"11' - 0"11' - 1"5' - 0"11' - 6"15' - 6"10' - 6"5' - 10"14' - 3"5' - 8"8' - 1"8' - 1"5' - 0"12' - 11"8' - 0"28' - 11"42' - 6"25' - 9"16' - 2"25' - 11"E304E303E3011A6.12A6.13A6.14A6.12A5.11A5.2BUILDING 5BUILDING 2BUILDING 6BUILDING 3BUILDING 4BUILDING 7BUILDING 8BUILDING 1(CLUBHOUSE)10" / 1'-0"10" / 1'-0"10" / 1'-0"6" / 1'-0"6" / 1'-0"10" / 1'-0"10" / 1'-0"6" / 1'-0"6" / 1'-0"10" / 1'-0"10" / 1'-0"10" / 1'-0"10" / 1'-0"10" / 1'-0"ZONE 15 ZONE 16 ZONE 17 ZONE 18R2TYPR1TYPR3TYPR4TYPR2TYPR1TYPR3TYPR4TYPR2TYPR2TYP1. PRIVATE CONCRETE PATIO AT UNIT, TYPICAL UNLESS OTHERWISE NOTED -SEE SITE PLAN2. COLUMN WRAPPED IN CEMENTITIOUS TRIM3. CONCRETE PAD AT EXITS -SEE CIVIL FOR SIDEWALK LEADING TO PADS4. FURRED WALL FOR EXTERIOR DECORATIVE DETAIL -SEE ELEVATIONS5. ROOF BELOW, SEE ROOF PLAN6. COVERED PORCH7. LINE OF SOFFIT, BEAM AND/ OR ROOF ABOVE8. RAISED CONCRETE PORCH9. UNIT TO BE 3BR-2 TYPE A AT BUILDING 3, UNIT TO BE 3BR-3 TYPE B AT BUILDING 510. UNIT TO BE 2BR-2 TYPE A AT BUILDINGS 2 AND 611. UNIT TO BE 1BR-2 TYPE A AT BUILDING 4, UNIT TO BE 2BR-1 TYPE B AT BUILDING 712. ATTIC ACCESS PANEL -SEE DETAIL 1/A6.313. ACCESSIBLE PUSH BUTTON OPERATOR -SEE ELECTRICAL14. ACCESS CONTROL MODULE -SEE ELECTRICALFLOOR PLAN KEYNOTES#1. FLOOR PLAN DIMENSIONS ARE TO:• EXTERIOR WALLS: OUTSIDE FACE OF SHEATHING OR OUTSIDE FACE OF MASONRY UNLESS OTHERWISE INDICATED.• INTERIOR WALLS: FACE OF CMU, STUDS, AND/OR CENTERLINE OF COLUMNS UNLESS OTHERWISE INDICATED.• RESIDENTIAL WINDOWS AND DOORS: CENTERLINE OF WINDOWS AND DOORS, UNLESS OTHERWISE INDICATED.• ALUMINUM STOREFRONT: FACE OF FRAMES UNLESS OTHERWISE INDICATED.2. DOOR FRAMES ARE 4”FROM ADJACENT WALLS UNLESS OTHERWISE INDICATED.3. PROVIDE BLOCKING FOR ALL WALL HUNG EQUIPMENT, CABINETS, ACCESSORIES, ETC. 4. PROVIDE WIRE STORAGE SHELVING IN THE FOLLOWING LOCATIONS:• BEDROOM CLOSETS, WALK IN CLOSETS (WIC), COATS, AND LAUNDRY: SHELF AND ROD. SHELF AND RODS ARE ADJUSTABLE AT TYPE A AND UFAS UNITS.• PANTRY AND LINEN: (5) STORAGE SHELVES.• RENT DROP CLOSET: (3) STORAGE SHELVES.5. SEAL BUILDING ENVELOPE PENETRATIONS TO PREVENT AIR LEAKAGE. SEAL WALLS BETWEEN DWELLING UNITS AND BETWEEN DWELLING UNITS AND OTHER SPACES FOR ACOUSTICAL AND AIR LEAKAGE.6. DO NOT SCALE DRAWINGS.7. EXTERIOR WALLS ARE WALL TYPE H1 UNLESS OTHERWISE INDICATED. 8. INTERIOR WALLS ARE WALL TYPE A1 UNLESS OTHERWISE INDICATED. 9. SEE OVERALL BUILDING FLOOR PLANS FOR ORIENTATION OF UNITS.GENERAL FLOOR PLAN NOTES1. ALL ROOF-MOUNTED EQUIPMENT AND PENETRATIONS ARE NOT SHOWN. COORDINATE QUANTITIES AND LOCATIONS WITH OTHER DISCIPLINES.GENERAL ROOF PLAN NOTESR1.ASPHALT ROOFINGR2.GUTTERR3.RIDGE VENTR4.DRAFTSTOPPING DOOR -SEE DETAIL 3/A6.3ROOF PLAN KEYNOTES#ROOF PLAN LEGENDSLOPE IN STRUCTURELINE OF WALL BELOWLINE OF DRAFTSTOPPING -SEE DETAIL 2/A6.3ROOF VENTILATION CALCULATIONS BLDG 7:ZONES 15: 2,279 SFVENTILATION REQUIRED: 2,279 SF / 300 = 7.6 SF OR 1,094.4 SI REQUIRED VENTILATION AT RIDGE: 547.2 SIPROVIDED VENTILATION AT RIDGE: 30' -5" RIDGE VENT (18 SI / LF) = 547.5 SI 547.5 SIREQUIRED VENTILATION AT EAVE: 547.2 SIPROVIDED VENTILATION AT EAVE:38.2 SF OF SOFFIT VENTING (14.34 SI / SF) = 547.8 SIZONES 16: 1,679 SFVENTILATION REQUIRED: 1,679 SF / 300 = 5.6 SF OR 806.4 SI REQUIRED VENTILATION AT RIDGE: 403.2 SIPROVIDED VENTILATION AT RIDGE:22' -5" RIDGE VENT (18 SI / LF) = 403.5 SI 403.5 SIREQUIRED VENTILATION AT EAVE: 403.2 SIPROVIDED VENTILATION AT EAVE:28.2 SF OF SOFFIT VENTING (14.34 SI / SF) = 404.4 SIZONES 17: 1,870 SFVENTILATION REQUIRED: 1,870 SF / 300 = 6.23 SF OR 897.12 SI REQUIRED VENTILATION AT RIDGE: 448.56 SIPROVIDED VENTILATION AT RIDGE:25' -0" RIDGE VENT (18 SI / LF) = 450 SI 450 SIREQUIRED VENTILATION AT EAVE: 448.56 SIPROVIDED VENTILATION AT EAVE:31.4 SF OF SOFFIT VENTING (14.34 SI / SF) = 450.3 SIZONES 18: 2,348 SFVENTILATION REQUIRED: 2,348 SF / 300 = 7.83 SF OR 1,127.52 SI REQUIRED VENTILATION AT RIDGE: 563.76 SIPROVIDED VENTILATION AT RIDGE:31' -4" RIDGE VENT (18 SI / LF) = 563.99 SI 563.99 SIREQUIRED VENTILATION AT EAVE: 563.76 SIPROVIDED VENTILATION AT EAVE:39.4 SF OF SOFFIT VENTING (14.34 SI / SF) = 565.99 SIROOF VENTILATION CALCULATION NOTES:1. ROOF VENTILATION CALCULATIONS PROVIDED BASED ON PLAN AREA.2. TRIPLE 4" BASKET WEAVE FULL SOFFIT PROVIDES 14.34 SQ. IN. NET FREE AREA PER SQ. FT.3. RIDGE VENT PROVIDES 18 SQ. IN. NET FREE ARE PER LIN. FT.4. DURA-FLOW 'TOP' CAP VENT #6075xx (MATCH ROOF COLOR) ROOF LOUVER PROVIDES 75 SQ. IN. NET FREE AREA PER UNIT.5. ALTERNATE CAP: LOMANCO MODEL 135 (MATCH ROOF COLOR) ROOF LOVER PROVIDES 144 SQ. IN. NET FREE AREA PER UNIT.ISSUANCE PROJECT NUMBERCopyright © 2023 HDJ Inc. All Rights ReservedC:\1-2020 Revit Projects\2022.0023 ARCH_tiffanya@hdjinc.com.rvt2/21/2023 2:06:44 PM2022.0023NORTH 3RD APARTMENTSNORTH 3RD APARTMENTS, LLCA1.8THIRD, FOURTHFLOOR & ROOFPLANS - BUILDING7N. 3RD AVENUE, BOZEMAN. MT 59715NEW APARTMENTS1/8" = 1'-0"A1.8THIRD & FOURTH FLOOR PLAN - BUILDING 71NOT TO SCALEKEYPLAN1/8" = 1'-0"A1.8ROOF PLAN - BUILDING 72NO. DATE DESCRIPTION