Loading...
HomeMy WebLinkAbout045_L4.1_IrrigationDetails1Project Number: Drawn By: Reviewed By: Approved By: Issue Date ThinkOne Architects 101 E Main St. Studio 1 Bozeman, MT, 59715 T: 406-586-7020 Architect MEP Engineer Landscape Architect Civil Engineer Seal Project Number Sanderson Stewart 106 East Babcock St. Suite L1 Bozeman, MT 59715 T: 406-522-9876 AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, CO 80211 T: 303-294-9448 Associate Architect Structural Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Sanderson Stewart 106 East Babcock St. Suite L1 Bozeman, MT 59715 T: 406-522-9876 1/25/2023 11:54:15 AML4.1 IRRIGATION DETAILS CS RPE RPE 21-723BARNARD OFFICE HQ 21-723 BOZEMAN, MT ROYAL WOLF WAY01/25/23SITE PLAN SUBMITTAL                         BARNARD CONSTRUCTION CONTROLLER - WALL MOUNT N.T.S. 13" OPEN DOOR WIDTH 5" ELECTRICAL SUPPLY CONDUIT CONNECT TO POWER SOURCE, J-BOX INSIDE CONTROLLER ADJACENT SURFACE TO MOUNT CONTROLLER PER PLAN ADJACENT SURFACE TO MOUNT CONTROLLER PER PLAN IRRIGATION CONTROL WIRE IN CONDUIT SIZE AND TYPE PER LOCAL CODES IRRIGATION CONTROLLER NOTES: 1.MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL. 2.CONTROLLER SHALL BE HARD-WIRED TO GROUNDED 110 VAC POWER SOURCE. RIGHT ELEVATION FRONT ELEVATION 1 MODEL MWS-FR OPTIMUM MOUNTING HEIGHT 6' ABOVE GRADE 2" PIPE MOUNT TO POST OR WITH CONDUIT CLAMPS RUN LEAD WIRES TO CONTROLLER NOTES: 1.FOR MOST ACCURATE TEMPERATURE SENSING, ROTATE THE MWS SO THAT THE THERMOSTAT PORTION POINTS SOUTH. THE MWS IS DESIGNED TO MOUNT ON A POST OF 2" PIPE, ANY COMBINATION OF PIPE AND FITTINGS MAY BE USED. HUNTER WEATHER STATION N.T.S.2 FROM WATER SOURCE TO IRRIGATION SYSTEM GROUND LEVEL BACKFLOW PREVENTOR BLOWOUT TEE WITH CAP COPPER PIPE MAIN LINE (PVC PIPE) COPPER PIPE 1.5' MININTERIOR POINT OF CONNECTION N.T.S. WATER METER WALL MOUNT BRACKETS NOTES: 1.POINT OF CONNECTION SHALL BE INSIDE MECHANICAL ROOM OF BUILDING. 2.VALVES SHALL BE WALL MOUNTED WITH APPROPRIATE BRACKETS. 3 18" PLANS SECTIONS DIRECT BURY PLAN DIRECT BURY SECTION TAPE & BUNDLE ALL WIRING AT 10' INTERVALS. USE 6" WIDE MARKING TAPE 6" ABOVE ALL DIRECT BURIAL WIRING. ALL SPLICES SHALL BE MADE IN VALVE BOXES AND LOCATED ON AS-BUILT PLANS (ALL 120 V). WIRING SHALL BE IN CONDUIT WITH MARKER TAPE AS ABOVE. ALL WIRING UNDER PAVEMENT & THROUGH SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE 20 INCH LOOP IN WIRING AT ALL CHANGES IN DIRECTION GREATER THAN 30 DEGREES. UNTIE ALL LOOPS AFTER MAKING CONNECTIONS. 18" CONDUIT SECTION CONDUIT PLAN 24" 36" 24" 36" LATERAL PIPE IN TRENCH SNAKE ALL FINISHED GRADE MARKING TAPE LOOP TIES FINISHED GRADE LATERAL MAIN LINE BEDDING LOW VOLTAGE WIRE OR 120V WIRE IN CONDUIT LATERAL TRENCHING DETAILS N.T.S.4 NOTES: 1.DIAMETERS OF PVC FITTINGS AND RISER SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER. 2.VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE. 3.PROVIDE 4 FT. MIN. SEPARATION BETWEEN ALL BOXES. 4.SEE SPECIFICATION FOR CONTROL VALVE INSTALLATION NOTES: 1.INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. VALVE BOX TO BE FLUSH WITH FINISH GRADE. RECTANGULAR VALVE BOX. BRAND LID WITH CONTROLLER & STATION #. REFER TO TECHNICAL SPECIFICATIONS. FINISHED GRADE ELECTRIC CONTROL VALVE PVC BALL VALVE (FxF) PROVIDE 29 1/2" CONTINUOUS COILS OF ALL OF ALL SPARE CONTROL/COMMON WIRING WITHIN VALVE BOX. SCH.40 PVC SLIPxMALE 90 ELL PEA GRAVEL ROCK SUMP - 1 CU. FT. SCH.80 PVC NIPPLE (LENGTH AS REQUIRED) SERVICE TEE - SOLVENT WELD COVER ROCK SUMP WITH SOIL FILTER FABRIC (FULL LENGTH AND WIDTH OF VALVE BOX) SCH.80 NIPPLE CUT OFF + GLUED 1" FILTER WITH 100 MICRON DISC FILTER ELEMENT RECTANGULAR VALVE BOX - BRAND LID WITH CONTROLLER AND STATION NUMBER # UNION FIPT X FIPT 1" PVC PVC BALL VALVE PVC PRESSURE MAINLINE CONTROL VALVE 1" PRESSURE REGULATING VALVE 3/4" CRUSHED GRAVEL SUMP - 1 CU. FT. PVC UNION - 1" (FIPTxFIPT) ELECTRIC CONTROL VALVE N.T.S. SPECIFIED LATERAL PIPING DEPTH MAINTAIN 8" VERTICAL CLEARANCE BETWEEN TOP OF PIPE & VALVE BOX 5 FINISHED GRADE PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 30" LINEAR LENGTH OF WIRE, COILED WATERPROOF CONNECTION: SPLICE-1 (1 OF 2) ID TAG VALVE BOX WITH COVER PVC SCH 40 FEMALE ADAPTER LATERAL PIPE BRICK (1 OF 4) 3" MINIMUM DEPTH OF 3/4" PEA GRAVEL CONTROL ZONE KIT: (INCLUDES 1" VALVE, BACK FLUSH PRESSURE REGULATING FILTER, DUCK BILL BOOT). PVC SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND PVC SCH 40 ELL PVC SCH 40 TEE OR ELL PVC MAINLINE 1" DRIP ZONE KIT N.T.S.3"8 AGGREGATE SHUT OFF VALVE IRRIGATION MAIN LINE VALVE BOX FLOW CONTROL VALVE N.T.S.9 VARIES 19.7" 6.6"9.8" TRIM INDIVIDUAL RINGS TO CONFORM TO IRRIGATION HEAD CONTOUR CUT AND REMOVE RINGS AND GRID TO ACCOMMODATE IRRIGATION HEAD, SIZE VARIES IRRIGATION HEAD WITH COVER PLATE VARIESCONCRETE SAND (CLEAN, SHARP SAND) HYDRO GROW MIX BELOW RINGS ONLY, SUPPLIED FREE BY MANUFACTURER COMPACTED SANDY GRAVEL ROAD BASE UNDER GRASSPAVE2 ONLY TAPER BASE TO SUPPORT EDGE OF GRASSPAVE2 SQUARE COMPACTED SUBGRADE 95% MODIFIED PROCTOR DENISTY EXCAVATE COMPACTED SUBGRADE AS REQUIRED TO PERMIT IRRIGATION HEAD INSTALLATION GRASSPAVE2 WITH IRRIGATION HEADS N.T.S. PLAN SECTION 6 2"12"12"12"12"12"2" F TYPICAL SUBSURFACE DRIPLINE SPACING N.T.S. PVC LATERAL TYPICAL FPT ADAPTER AND COMPRESSION COUPLER POLYETHETHULENE OR PVC HEADER DRIPLINE SPACING FLUSH VALVE ON EVERY END SECTION OF DRIPLINE TIE DOWN STAKE AT ALL TEES, ELBOWS, AND AT 4' O.C. AT CLAY, 3' O.C. AT LOAM, OR 2' O.C. AT SAND NOTES: 1.ALL DRIPLINE TO BE STAKED DOWN WITH METAL SOD STAPLES. 2.BOULEVARD WIDTH VARIES. DRIPLINE SHALL BE PLACED 2" OFF OF HARDSCAPE AND SPACING SHALL BE 12" O.C. SIDEWALK/CURB SIDEWALK/CURB 7