HomeMy WebLinkAbout045_L4.1_IrrigationDetails1Project Number:
Drawn By:
Reviewed By:
Approved By:
Issue Date
ThinkOne Architects
101 E Main St. Studio 1
Bozeman, MT, 59715
T: 406-586-7020
Architect
MEP Engineer
Landscape Architect
Civil Engineer
Seal
Project Number
Sanderson Stewart
106 East Babcock St.
Suite L1
Bozeman, MT 59715
T: 406-522-9876
AndersonMasonDale Architects, P.C.
3198 Speer Boulevard
Denver, CO 80211
T: 303-294-9448
Associate Architect
Structural Engineer
Morrison-Maierle, Inc.
2880 Technology Blvd.
Bozeman, MT 59715
T: 406-587-0721
Morrison-Maierle, Inc.
2880 Technology Blvd.
Bozeman, MT 59715
T: 406-587-0721
Sanderson Stewart
106 East Babcock St.
Suite L1
Bozeman, MT 59715
T: 406-522-9876
1/25/2023 11:54:15 AML4.1
IRRIGATION DETAILS
CS
RPE
RPE
21-723BARNARD OFFICE HQ
21-723
BOZEMAN, MT
ROYAL WOLF WAY01/25/23SITE PLAN SUBMITTAL
BARNARD CONSTRUCTION
CONTROLLER - WALL MOUNT
N.T.S.
13" OPEN DOOR WIDTH
5"
ELECTRICAL SUPPLY CONDUIT
CONNECT TO POWER SOURCE,
J-BOX INSIDE CONTROLLER
ADJACENT SURFACE TO MOUNT
CONTROLLER PER PLAN ADJACENT SURFACE TO
MOUNT CONTROLLER PER
PLAN
IRRIGATION CONTROL
WIRE IN CONDUIT
SIZE AND TYPE PER
LOCAL CODES
IRRIGATION
CONTROLLER
NOTES:
1.MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL.
2.CONTROLLER SHALL BE HARD-WIRED TO
GROUNDED 110 VAC POWER SOURCE.
RIGHT ELEVATION
FRONT ELEVATION
1
MODEL MWS-FR
OPTIMUM MOUNTING
HEIGHT 6' ABOVE GRADE
2" PIPE
MOUNT TO POST OR WITH
CONDUIT CLAMPS
RUN LEAD WIRES
TO CONTROLLER
NOTES:
1.FOR MOST ACCURATE TEMPERATURE SENSING, ROTATE
THE MWS SO THAT THE THERMOSTAT PORTION POINTS
SOUTH. THE MWS IS DESIGNED TO MOUNT ON A POST
OF 2" PIPE, ANY COMBINATION OF PIPE AND FITTINGS
MAY BE USED.
HUNTER WEATHER STATION
N.T.S.2
FROM WATER
SOURCE
TO IRRIGATION
SYSTEM
GROUND LEVEL
BACKFLOW PREVENTOR
BLOWOUT TEE WITH CAP
COPPER PIPE
MAIN LINE
(PVC PIPE)
COPPER PIPE 1.5' MININTERIOR POINT OF CONNECTION
N.T.S.
WATER METER
WALL MOUNT BRACKETS
NOTES:
1.POINT OF CONNECTION SHALL BE INSIDE
MECHANICAL ROOM OF BUILDING.
2.VALVES SHALL BE WALL MOUNTED WITH
APPROPRIATE BRACKETS.
3
18"
PLANS
SECTIONS
DIRECT BURY PLAN
DIRECT BURY SECTION
TAPE & BUNDLE ALL WIRING AT 10' INTERVALS.
USE 6" WIDE MARKING TAPE 6" ABOVE ALL
DIRECT BURIAL WIRING.
ALL SPLICES SHALL BE MADE IN VALVE BOXES
AND LOCATED ON AS-BUILT PLANS (ALL 120 V).
WIRING SHALL BE IN CONDUIT WITH MARKER
TAPE AS ABOVE.
ALL WIRING UNDER PAVEMENT & THROUGH
SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE 20
INCH LOOP IN WIRING AT ALL CHANGES IN
DIRECTION GREATER THAN 30 DEGREES. UNTIE
ALL LOOPS AFTER MAKING CONNECTIONS.
18"
CONDUIT SECTION
CONDUIT PLAN
24" 36" 24" 36"
LATERAL PIPE IN
TRENCH SNAKE ALL
FINISHED GRADE
MARKING TAPE
LOOP
TIES
FINISHED GRADE
LATERAL
MAIN LINE
BEDDING
LOW VOLTAGE WIRE OR 120V WIRE IN CONDUIT
LATERAL
TRENCHING DETAILS
N.T.S.4
NOTES:
1.DIAMETERS OF PVC FITTINGS AND RISER SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER.
2.VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS
AND HARD SURFACES WHERE APPLICABLE.
3.PROVIDE 4 FT. MIN. SEPARATION BETWEEN ALL BOXES.
4.SEE SPECIFICATION FOR CONTROL VALVE INSTALLATION
NOTES:
1.INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN
ENTIRE ASSEMBLY WITHIN BOX. VALVE BOX TO BE FLUSH
WITH FINISH GRADE.
RECTANGULAR VALVE BOX. BRAND LID WITH
CONTROLLER & STATION #. REFER TO TECHNICAL
SPECIFICATIONS.
FINISHED GRADE
ELECTRIC CONTROL VALVE
PVC BALL VALVE (FxF)
PROVIDE 29 1/2" CONTINUOUS COILS OF ALL
OF ALL SPARE CONTROL/COMMON WIRING
WITHIN VALVE BOX.
SCH.40 PVC SLIPxMALE 90 ELL
PEA GRAVEL ROCK SUMP - 1 CU. FT.
SCH.80 PVC NIPPLE (LENGTH AS REQUIRED)
SERVICE TEE - SOLVENT WELD
COVER ROCK SUMP WITH SOIL FILTER FABRIC
(FULL LENGTH AND WIDTH OF VALVE BOX)
SCH.80 NIPPLE CUT OFF + GLUED
1" FILTER WITH 100 MICRON
DISC FILTER ELEMENT
RECTANGULAR VALVE BOX -
BRAND LID WITH
CONTROLLER AND
STATION NUMBER #
UNION FIPT X FIPT
1" PVC
PVC BALL VALVE
PVC PRESSURE MAINLINE
CONTROL VALVE
1" PRESSURE REGULATING VALVE
3/4" CRUSHED GRAVEL SUMP - 1 CU. FT.
PVC UNION - 1" (FIPTxFIPT)
ELECTRIC CONTROL VALVE
N.T.S.
SPECIFIED LATERAL PIPING
DEPTH MAINTAIN 8"
VERTICAL CLEARANCE
BETWEEN TOP OF PIPE &
VALVE BOX
5
FINISHED GRADE
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)
30" LINEAR LENGTH OF WIRE, COILED
WATERPROOF CONNECTION: SPLICE-1 (1 OF 2)
ID TAG
VALVE BOX WITH COVER
PVC SCH 40 FEMALE ADAPTER
LATERAL PIPE
BRICK (1 OF 4)
3" MINIMUM DEPTH OF 3/4" PEA
GRAVEL
CONTROL ZONE KIT: (INCLUDES 1" VALVE,
BACK FLUSH PRESSURE REGULATING
FILTER, DUCK BILL BOOT).
PVC SCH 80 NIPPLE (2-INCH LENGTH,
HIDDEN) AND PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
PVC MAINLINE
1" DRIP ZONE KIT
N.T.S.3"8
AGGREGATE
SHUT OFF VALVE
IRRIGATION
MAIN LINE
VALVE BOX
FLOW CONTROL VALVE
N.T.S.9
VARIES
19.7"
6.6"9.8"
TRIM INDIVIDUAL RINGS TO
CONFORM TO IRRIGATION HEAD CONTOUR
CUT AND REMOVE RINGS AND GRID
TO ACCOMMODATE IRRIGATION HEAD,
SIZE VARIES
IRRIGATION HEAD WITH
COVER PLATE
VARIESCONCRETE SAND (CLEAN, SHARP SAND)
HYDRO GROW MIX BELOW
RINGS ONLY, SUPPLIED
FREE BY MANUFACTURER
COMPACTED SANDY GRAVEL
ROAD BASE UNDER GRASSPAVE2
ONLY TAPER BASE TO SUPPORT
EDGE OF GRASSPAVE2 SQUARE
COMPACTED SUBGRADE
95% MODIFIED PROCTOR DENISTY
EXCAVATE COMPACTED SUBGRADE
AS REQUIRED TO PERMIT IRRIGATION
HEAD INSTALLATION
GRASSPAVE2 WITH IRRIGATION HEADS
N.T.S.
PLAN
SECTION
6
2"12"12"12"12"12"2"
F
TYPICAL SUBSURFACE DRIPLINE SPACING
N.T.S.
PVC LATERAL
TYPICAL FPT ADAPTER
AND COMPRESSION
COUPLER
POLYETHETHULENE
OR PVC HEADER
DRIPLINE SPACING
FLUSH VALVE ON EVERY
END SECTION OF DRIPLINE
TIE DOWN STAKE AT ALL
TEES, ELBOWS, AND
AT 4' O.C. AT CLAY, 3' O.C.
AT LOAM, OR 2' O.C. AT SAND
NOTES:
1.ALL DRIPLINE TO BE STAKED DOWN WITH METAL SOD STAPLES.
2.BOULEVARD WIDTH VARIES. DRIPLINE SHALL BE PLACED 2" OFF
OF HARDSCAPE AND SPACING SHALL BE 12" O.C.
SIDEWALK/CURB
SIDEWALK/CURB
7