Loading...
HomeMy WebLinkAbout004_C4.0_OverallSiteAndUtilityPlanNORTH 0 60 SCALE: 1" = 60' 1203060 Project Number: Drawn By: Reviewed By: Approved By: Issue Date ThinkOne Architects 101 E Main St. Studio 1 Bozeman, MT, 59715 T: 406-586-7020 Architect MEP Engineer Landscape Architect Civil Engineer Seal Project Number Sanderson Stewart 106 East Babcock St. Suite L1 Bozeman, MT 59715 T: 406-522-9876 AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, CO 80211 T: 303-294-9448 Associate Architect Structural Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Sanderson Stewart 106 East Babcock St. Suite L1 Bozeman, MT 59715 T: 406-522-9876 3/29/2023 3:49:27 PMC4.0 OVERALL SITE AND UTILITY PLAN CS RPE RPE 21-723BARNARD OFFICE HQ 21-723 BOZEMAN, MT ROYAL WOLF WAY01/25/23SITE PLAN SUBMITTAL 03/29/23SITE PLAN RESUBMITTAL                         BARNARD CONSTRUCTION UULC PHILLIPS 66 PIPELINE NOTES: 1.WARNING HIGH PRESSURE PIPELINE(S). NO EXCAVATION OR CONSTRUCTION IN THIS AREA WITHOUT ONE-CALL AND WITHOUT CONTACTING PHILLIPS 66 PIPELINE LLC (P66PL) AT (406) 587-7060. 2.CONTRACTOR TO CONTACT YELLOWSTONE PIPELINE REPRESENTATIVE AT LEAST 72 HOURS PRIOR TO ANY WORK NEAR OR WITHIN THE EASEMENT. YELLOWSTONE PIPELINE REPRESENTATIVE MUST BE PRESENT ON-SITE DURING ALL EXCAVATION ACTIVITIES WITHIN THE EASEMENT 3.PROPOSED BUILDING MUST BE 50' MINIMUM FROM EXISTING YELLOWSTONE PIPELINE. 4.PROPOSED GEOTHERMAL WELL PIPING MUST PASS UNDERNEATH THE EXISTING YELLOWSTONE PIPELINE(S) BY A MINIMUM OF 24 INCHES. 5.DURING INSTALLATION OF UNDERGROUND PIPELINES OR FACILITIES WITH DRILLING OR BORING TECHNOLOGY, AN AUTHORIZED PERMITTOR REPRESENTATIVE SHALL HAVE THE RIGHT TO EVALUATE AND APPROVE THE DRILLING PLAN. FOR A DRILLED CROSSING, PROVIDE AT LEAST 10 FT OF VERTICAL SEPARATION FOR CROSSINGS AND 15 FT FOR PARALLEL BORES BETWEEN NEW AND BORE AND EXISTING PIPELINES. IN ADDITION, PHILLIPS 66 MAY REQUIRE PERMITTEE TO EXCAVATE AN OBSERVATION HOLE PARALLEL TO AND APPROXIMATELY 5FT ON ONE OR BOTH SIDES OF PERMITTOR'S PIPELINE(S) EXTENDING AT LEAST 1 FT BELOW THE PIPELINE OR BORE, WHICHEVER IS SHALLOWEST. THE OBSERVATION HOLES(S) ARE TO BE MONITORED DURING BOTH THE PILOT BORE AND BACK REAMING. 6.PERMITTEE WILL REMOVE CUTTING TEETH FROM EXCAVATION EQUIPMENT BUCKET WHEN WITHIN 10 FEET OF PERMITTOR'S PIPELINE(S). MECHANICAL EXCAVATION WILL CEASE, AND ONLY HAND EXCAVATION SHALL BE PERMITTED, WITHIN 18 INCHES OF A CRUDE OIL OR PRODUCT PIPELINE AND WITHIN 24 INCHES OF A LINE CONTAINING HIGHLY VOLATILE LIQUIDS (HVL). EXCAVATION WILL NOT BE ALLOWED TO CONTINUE UNTIL THE PERMITTOR'S PIPELINE, VALVES, AND/OR FITTINGS TOP AND SIDES ARE VISIBLE TO THE SPOTTER. HOWEVER, PROCEED WITH EXTREME CAUTION WHEN WITHIN THREE (3) FEET OF THE PIPE. GEOTHERMAL PIPING NOTES: 1.GEOTHERMAL WATER PIPE SHALL BE PVC C900 DR 14. 2.GEOTHERMAL WATER PIPE SHALL BE RESTRAINED AND CONSTRUCTED IN ACCORDANCE WITH THE MPWSS WATER LINE SPECIFICATIONS. 3.SEE MECHANICAL AND GEOTHERMAL WELL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.