HomeMy WebLinkAbout003_C3.0_ExistitngSiteAndDemoPROJECT SURVEY CONTROL (LDP) Point # 202 204 207 209 212 215 Northing (IFT) 138301.31 138118.90 138173.16 138709.36 139059.70 138684.57 Easting (IFT) 370174.94 370220.23 369843.21 369116.23 369526.85 369655.13 Elevation (USSF) 4600.20 4598.27 4603.69 4600.32 4597.37 4599.39 Description PC /OCR MORRISON MAIERLE 16411LS PC /OCR MORRISON MAIERLE 16411LS PC /OCR MORRISON MAIERLE 16411LS PC /OCR MORRISON MAIERLE 16411LS PC /OCR MORRISON MAIERLE 16411LS PC /OCR MORRISON MAIERLE 16411LS PROJECT DATUM: LOW DISTORTION PROJECTION COORDINATE SYSTEM (LDP MT83-BOZ-IF) NORTH AMERICAN DATUM OF 1983 SURVEYED: 10/10/22 BY: SANDERSON STEWART NORTH 0 60 SCALE: 1" = 60' 1203060 Project Number: Drawn By: Reviewed By: Approved By: Issue Date ThinkOne Architects 101 E Main St. Studio 1 Bozeman, MT, 59715 T: 406-586-7020 Architect MEP Engineer Landscape Architect Civil Engineer Seal Project Number Sanderson Stewart 106 East Babcock St. Suite L1 Bozeman, MT 59715 T: 406-522-9876 AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, CO 80211 T: 303-294-9448 Associate Architect Structural Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Sanderson Stewart 106 East Babcock St. Suite L1 Bozeman, MT 59715 T: 406-522-9876 3/29/2023 3:49:16 PMC3.0 EXISTING SITE AND DEMOLITION PLAN CS RPE RPE 21-723BARNARD OFFICE HQ 21-723 BOZEMAN, MT ROYAL WOLF WAY01/25/23SITE PLAN SUBMITTAL 03/29/23SITE PLAN RESUBMITTAL                         BARNARD CONSTRUCTION SITE DEMOLITION NOTES: 1.ALL LOCATIONS AND DIMENSIONS OF EXISTING AND PROPOSED FEATURES ARE APPROXIMATE AND THE PROJECT DRAWINGS MAY NOT INCLUDE ALL EXISTING FEATURES WITHIN THE PROJECT BOUNDARIES. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO BECOME FAMILIAR WITH THE EXISTING SITE FEATURES AND CONDITIONS. IF DISCREPANCIES ARE FOUND BETWEEN THE PROJECT DRAWINGS AND FIELD CONDITIONS THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER FOR CLARIFICATION. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING AND PAYING FOR ALL PERMITS NECESSARY TO COMPLETE THE PROPOSED WORK INCLUDING DEMOLITION, RIGHT-OF-WAY AND ENVIRONMENTAL PERMITS. 3.ALL PUBLIC AND PRIVATE UTILITY TERMINATIONS, DISCONNECTS AND REMOVALS TO BE COORDINATED WITH THE APPLICABLE UTILITY PROVIDERS AND PERFORMED IN ACCORDANCE TO THEIR RESPECTIVE STANDARDS AND SPECIFICATIONS. 4.ALL EXISTING ASPHALT, CONCRETE AND OTHER EXISTING FACULTIES WITHIN THE “DEMO AREA” TO BE REMOVED AND PROPERLY DISPOSED IN ACCORDANCE TO ALL FEDERAL, STATE AND LOCAL REGULATIONS. 5.ALL REMOVED, DISTURBED OR DAMAGED EXISTING ASPHALT, CURB AND GUTTER, PUBLIC SIDEWALK AND PAVEMENT MARKINGS WITHIN THE PUBLIC RIGHT-OF-WAY TO BE RESTORED IN ACCORDANCE TO CITY STANDARDS. ALL ASPHALT MATCH LINES SHALL BE SAW CUT TO PROVIDE FLUSH TRANSITION AND SEALED. 6.ALL EXISTING UNDERGROUND SERVICE STUBS WHICH ARE NOT UTILIZED FOR THE PROPOSED BUILDING SHALL BE REMOVED AND PLUGGED BACK TO THE EXISTING MAIN. ANY EXISTING PIPING WITHIN THE PROPOSED BUILDING AREA SHALL BE REMOVED & DISPOSED. 7.ALL EXCAVATIONS OR VOIDS CREATED DURING DEMOLITION SHALL BE BACKFILLED AND COMPACTED IN A CONTROLLED MANNER PER THE PROJECT GEOTECHNICAL REQUIREMENTS. SEE REQUIREMENTS IN THE GEOTECHNICAL REPORT. 8.ALL UTILITY JUNCTION BOXES TO BE PROTECTED IN PLACE UNLESS OTHERWISE NOTED. 9.ALL TREES AND SHRUBS SHALL BE PROTECTED IN PLACE UNLESS OTHERWISE NOTED. SEE TREE PROTECTION PLAN AND NOTES. PHILLIPS 66 PIPELINE NOTES: 1.WARNING HIGH PRESSURE PIPELINE(S). NO EXCAVATION OR CONSTRUCTION IN THIS AREA WITHOUT ONE-CALL AND WITHOUT CONTACTING PHILLIPS 66 PIPELINE LLC (P66PL) AT (406) 587-7060. 2.CONTRACTOR TO CONTACT YELLOWSTONE PIPELINE REPRESENTATIVE AT LEAST 72 HOURS PRIOR TO ANY WORK NEAR OR WITHIN THE EASEMENT. YELLOWSTONE PIPELINE REPRESENTATIVE MUST BE PRESENT ON-SITE DURING ALL EXCAVATION ACTIVITIES WITHIN THE EASEMENT