Loading...
HomeMy WebLinkAbout020 A4.11 Building Floor Plan - Level 2DN DN DN DN DNDN DN 1 A5.12 1 A5.121/ A5.104/ A5.113/ A5.11 BB 1 1 2 2 AA A6.10 2 A6.13 2 A6.14 2 A6.11 2 A6.12 2 9 A7.02 7 A7.07 ROOF BELOW ROOF BELOW 1 A7.47 1 A7.02 6 A7.27 5 A7.27 2 A7.47 3 A7.02 3 A7.02 6 A7.27 5 A7.27 2 A7.02 9 A7.02 1 A7.02 3 A7.02 3 A7.02 9 A7.02 7 A7.07 3 A7.02 1 A7.02 1 A7.024/ A5.153/ A5.15 2/ A5.14UNIT C1U A3.16 200 2% SLOPE TO DRAIN2% SLOPE TO DRAIN2% SLOPE TO DRAINUNIT B3U A3.14 201 UNIT C1U A3.16 202 UNIT B1U A3.11 206 UNIT A1U A3.10 205 UNIT A1U A3.10 204 46' - 2 1/2"1"36' - 0"1"46' - 2 1/2"39' - 7 1/2"1"36' - 2"140' - 6 1/2"2/ A5.101/ A5.14 42' - 9 1/2"1"28' - 3 1/2"1"4' - 7"1"28' - 4 1/2"36' - 3"43' - 4 1/2"1"39' - 7 1/2"128' - 7" 3 A5.12 3 A5.1283' - 1"75' - 10 1/2"UNIT B2U A3.12 203 ROOF BELOW ROOF BELOW ROOF BELOW 3 A7.02 3 A7.02 3 A7.02 1 A7.02 7 A7.07 3 A7.02 3 A7.02 7 A7.02 3 A7.02 9 A7.02 7 A7.07 9 A7.02 7 A7.07 9 A7.02 7 A7.07 7 A7.02 1 A7.02 A6.10 2 3 A7.02 3 A7.02 SL O P E T O D R AIN W IT H O V E R FL O W SLOPE TO DRAIN WITH OVER FLOWS L O P E T O D R A IN W IT H O V E R F L O W 1 A7.02 3 A7.02 9 A7.02 7 A7.07 A6.14 2 2 A7.02 3 A7.02 3 A7.02 3 A7.02 3 A7.02 9 A7.02 7 A7.07 3 A7.02 3 A7.02 SLOPE TO DRAIN WITH OVER FLOW 6 A7.27 5 A7.27 A7.45 1 1 A7.47 A7.45 1 6 A7.27 6 A7.27 6 A7.27 7 A7.61 5 A7.27 5 A7.27 5 A7.27 5 A7.27 36' - 5" 3' - 8"3' - 11 1/2"1 A7.61 6' - 0"13' - 5" 12' - 0"6' - 0"13' - 5"6' - 0"PLAN LEGEND ASSUMED PROPERTY LINE F.E. OCCUPANCY CLASIFICATIONS 1. BUILDING PLANS ARE SHOWN UNIT TO UNIT RELATIONSHIPS. REFER TO ENLARGED UNITS, STAIR AND ELEVATOR CORE PLANS FOR LAYOUT AND PLAN SPECIFIC INFORMATION NOT SHOWN. WHEN CONFLICTS EXIST OR INFORMATION IS UNCLEAR, CONTRACTORS SHALL CONSULT THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION ACTIVITIES. 2. ALL PARTY WALLS ARE SEPARATED BY A MIN. 1" AIRSPACE SEE BUILDING PLAN TO VERIFY. TYPICAL UNIT PARTY WALLS PER DETAIL 5 / A7.02. 3. FIRE WALLS PER DETAILS ON SHEET 13/A7.02 & A7.06 THRU A7.06C 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, UNLESS NOTED OTHERWISE. 5. REFER TO LANDSCAPE PLANS FOR COURTYARD HARDSCAPE, LANDSCAPE PLANTERS, AND PODIUM LEVEL DRAINAGE INFORMATION NOT SHOWN. SEE ENLARGED UNIT PLANS FOR PRIVATE DECK DRAINAGE. APL 1-HOUR WALL CR IC 2X6 WALL 1HR FIRE BARRIER FIRE EXTINGUISHER CARD KEY ACCESS INTERCOM ACCESS AREA OF USE OCCUPANCY NOTES: 1. ALL DOOR AND OPENINGS BETWEEN ROOMS OF DIFFERENT OCCUPANCIES TO HAVE ONE-HOUR PROTECTION PER I.B.C. TABLE 715.4. SEE DOOR SCHEDULE SHEET A2.01 FOR REQUIRED DOOR RATINGS. 2.ALL DUCTS PASSING BETWEEN OCCUPANCIES ARE REQUIRED TO HAVE ONE-HOUR SEPARATION OR MORE, TO HAVE CLASS II COMBINATION SMOKE / FIRE DAMPERS, VERIFY SPECIFIC REQUIREMENTS WITH MECHANICAL PLANS. AL-APARTMENTS FINISH FLOOR ELEVATIONS FINISH FLOOR ELEVATIONS ARE BASED ON A DATUM ELEVATION OF 100.00' AT THE TOP OF SLAB AT THE INSIDE OF THE UNITS. SEE THE ARCHITECTURAL SITE PLAN FOR ACTUAL GRADE AT DATUM. VERIFY ACTUAL DATUM WITH CIVIL PLANS. BUILDING PLAN NOTES ADA ACCESS REQUIREMENTS REFER TO ARCHITECTURAL SHEETS A1.01 TO A1.05 FOR TYPICAL ACCESSIBILITY NOTES AND INFORMATION 3. SEE SHEETS A1.40 & A1.43 FOR THROUGH AND MEMBRANE PENETRATIONS OF HORIZONTAL ASSEMBLIES AND FIRE RATED WALLS 4. THERE WILL BE A FIRE BARRIER WITH 1 HR. RATED WALL PER DETAIL 4/A7.06 AT COMMON AREA / CORRIDOR GENERAL NOTES 6. SEE TYPICAL UNIT PLAN FOR INFORMATION FOR SLOPES. SEE EXTERIOR ELEVATIONS FOR SCUPPER LOCATIONS, MISCELLANEOUS DETAILS AND ADDITIONAL INFORMATION. 7. SEE EXTERIOR ELEVATIONS FOR EXTERIOR RAILING TYPES AND DETAIL REFERENCING. 8. SEE CIVIL PLANS FOR FINISH GRADE ELEVATIONS. 9. SEE SHEETS A7.00 - A7.05 FOR TYPICAL ASSEMBLIES. 10. SEE FIRST LEVEL BUILDING PLAN FOR BUILDING ASSEMBLIES, PAVING, AND TYPICAL NOTES AND INFORMATION. 11. BUILDING FINISHES AND FINISH SCHEDULE PER OWNER 12. GLAZING UPGRADES ARE INDICATED PER ACOUSTICAL REPORT. SEE WINDOW SCHEDULE SHEET A2.10 FOR LOCATIONS OF UPGRADES IN THE UNITS. 13. EXIT SIGNS LOCATED PER FIRE DEPARTMENT COMMENT. SEE SYMBOL ON BUILDING PLANS FOR LOCATIONS. VERIFY WITH ELECTRICAL DRAWINGS. FIELD VERIFY LINE OF SITE TO EACH SIGN AND ADJUST MOUNTING HEIGHT AND LOCATION TO AVOID OBSTRUCTIONS. 14. PROVIDE FIRE EXTINGUISHER PER FIRE DEPARTMENT NOTES ON SHEET A0.11. 15. SEE MECHANICAL PLANS FOR LOCATIONS TO PROVIDE BLOCK-OUTS FOR THRU WALL VENTS AND EXHAUST FANS. 16. PROVIDE HOUSEKEEPING PADS FOR MECHANICAL AND ELECTRICAL EQUIPMENT. PROVIDE STRUCTURAL SUPPORT AT CLG. OF ELECT. ROOM FOR CABLE PULL PER LOCAL POWER CO. REQUIREMENTS. 17. HC SYMBOL DENOTES UNIT TO BE PROVIDED WITH REPOSTIONABLE COUNTERTOP AT KITCHEN SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 18. PER TABLE 803.9 CORRIDORS, EXIT ENCLOSURES, & EXIT PASSAGEWAYS SHALL BE LIMITED TO A CLASS 'C' FINISH WITH FLAME SPREAD OF '76-200' AND SMOKE DEVELOPED OF '0-450' AND SHALL BE TESTED PER 803.2 19. SEE CORE PLANS AND STAIR PLAN FOR FIRE RATED ASSEMBLIES. SEE SHEETS A1.40 & A1.43 FOR PENETRATION THROUGH ASSEMBLIES. 20. ALL TELE / DATA ROOMS SHALL BE A MINIMUM OF ONE-HOUR CONSTRUCTION. 21. HC SYMBOL DENOTES COMPLYING GUEST ROOMS WITH ADAS 701, 702 , 703, & 704 FOR MOBILITY AND COMMUNICATION UNITS. SEE SHEET A1.03 & A1.04 FOR ACCESSIBILITY NOTES REGARDING COMPLYING BATHROOMS. KEY NOTES A. PROVIDE HANDRAILS AT EACH SIDE OF CORRIDOR PER NAC CHAPT. 449.74539 TO COMPLY WITH ANSI 505.4 & 505.9 DOWNSPOUT AT GRADEDS AREA OF USE STORAGE AND UTILITY CLOSETS, INCIDENTIAL ROOMS. R2 R2 ARCHITECTS, L.P.5339 ALPHA ROAD · SUITE 300 · DALLAS · TX 75240P: (972) 701.9636 · F: (972) 701.9639HUMPHREYS PARTNERS&DALLAS · CHARLOTTE · CHICAGO · DENVER · NEW ORLEANS · NEW YORK NEWPORT BEACH · ORLANDO · SCOTTSDALE · CHENNAI · HANOILONDON · MONTEVIDEO · MEXICO CITY · TORONTOwww.humphreys.comThe architectural works depicted herein are the sole property of Humphreys & Partners Architects, L.P. and may not be constructed or used without its express written permission. No permission to modify or reproduce any of the architectural works, including without limitation the construction of any building, is expressed or should be implied from delivery of preliminary drawings or unsealed construction drawings. Permission to construct the building depicted in sealed construction drawings is expressly conditioned on the full and timely payment of all fees otherwise due Humphreys & Partners Architects, L.P. and, in the absence of any written agreement to the contrary, is limited to a one-time use on the site indicated on these plans. © by Humphreys & Partners Architects, L.P. All Rights Reserved Designed by: SHEET CONTENTS SHEET NO. Drawn by: Architect of Record: Issue for Pricing / Bidding: Issue for Permit Application: Issue for Construction: Date Plotted: A4.11 BRIDGER LAND GROUPBLOCK 14 APARTMENTSAuthor HPA# 21135 Designer 03/13/2023 03/13/2023 100% DD SETVince Chupka 2023 BOZEMAN, MTBUILDING UPPER LEVEL FLOOR PLAN 3/16" = 1'-0"1 LEVEL 2 - OVERALL FLOOR PLAN Revisions # DATE COMMENTS