Loading...
HomeMy WebLinkAbout002 A0.20 Architectural Site PlanCO CO S D DS S DS DS DS DS DS DSDS DS DSDS D DS D D DS DS DS DS DS DS DS DS DS DS S DS DSD SDS SS SSOSWOSWOSWOSWOSW OSW OSW OSWOSW OSW OSWCO CO CO CO CO CO CO CO CO CO CO CO CO CO CO CO W VW VCO W VW V SS OSW OSWBLDG #36 BLDG #37 BLDG #32 BLDG #31 BLDG #38 BLDG #39 BLDG #40 BLDG #41 BLDG #42 BLDG #43 BLDG #44 BLDG #45 BLDG #30 BLDG #29 BLDG #28 BLDG #27 BLDG #26 11 SPACES5 SPACESBLACKWOOD ROADCANTER AVENUEWINTERTHUR AVENUE1+002+003+004+005+005+10.01P P PHYDHYDSSSS SSSS HYDSSSS OSW OSWHYD OSWOSWOSW 31.9' 3.7' 20.00°' 5.5' 86.8' R34.3' 353.01 37.00 202.1250.00360.01 30.00 UP UP UP UP UP UP UP DN UP UP UP UP UP UPUP DN GAR -B3-UGAR -A1-UGAR -C1-LGAR - C1-UGAR -B1-U GAR-B3-L GAR -A1-U GAR -C1-L GAR -C1-U GAR -B2-U RISER/ FDC GAR -C1-U GAR -B2-U RISER/ FDC GAR -C1-L GAR -A1-U GAR-B3-L GAR -B3-U GAR -A1-U GAR -C1-L GAR - C1-U GAR -B1-U METER W/ LANDSCAPE SCREEN METER W/ LANDSCAPE SCREEN UNIT C1L UNIT B3L UNIT C1L UNIT C1L UNIT B3L UNIT C1L TYPE B TYPE B TYPE B TYPE B TYPE B ✳✳ 10' SET BACK 15' SET BACK 10' SET BACK10' SET BACK#1 MIRRORED SEE A4.10 BH 2 #2 SEE A4.10 BH 13' - 3"15' - 1 3/4"10' - 8 1/2" 10' - 2 3/4" T T TYPE B 47' - 6 3/4" ** * * * LIGHT POLE SNOW STORAGE * 5' WIDE CONCRETE WALK TO UNIT(TYP. @ EACH ENTRY) -SEE CIVIL F.H.F.H. REFER TO SUBDIVISION LANDSCAPING PLANS FOR LINEAR PARK IMPROVEMENTS (TYP.) EX. 30' PUBLIC ACCESS AND UTILITY EASEMENT 44' - 11 1/2"67' - 0" CLCL CLCLCLCLCL CLPUBLIC WALK, SEE CIVIL 30' - 0" PUBLIC WALK, SEE CIVIL PUBLIC WALK, SEE CIVIL 10' SET BACK SETBACK PROPERTY LINE SEPARATE SITE PLAN APPLICATION -BLOCK 14 COTTAGES (#22324) RAMP RAMP RAMP RAMP RAMP F.F.E.: 5022.40 BUILDING #1 WEST ELEVATION: AREA OF TRANSPARENCY = 288.6 SF TRANSPARENCY PERCENTAGE = 238.5 SF/1,822 SF = 15.8% BUILDING #2 EAST ELEVATION: AREA OF TRANSPARENCY = 288.6 SF TRANSPARENCY PERCENTAGE = 238.5 SF/1,822 SF = 15.8% BUILDING #1 SOUTH ELEVATION: AREA OF TRANSPARENCY = 891 SF TRANSPARENCY PERCENTAGE = 891 SF/2,923 SF = 30% BUILDING #2 SOUTH ELEVATION: AREA OF TRANSPARENCY = 891 SF TRANSPARENCY PERCENTAGE = 891 SF/2,923 SF = 30% F.F.E.: 5023.50 RAMP (22.39) (22.39) (22.39)(23.49) (23.49) (23.49) MAIL BOX BIKE RACK (22.39) (22.39) (21.39)(21.39)(21.39) (22.39) (22.39) 140' - 9 1/2"83' - 4"140' - 9 1/2"83' - 4"122' - 1"13' - 3"71' - 0"71' - 0"122' - 1" SYMBOL LEGEND - SITE PLAN ACCESSIBLE ROUTE IN COMPLIANCE WITH 2010 ADA SECTIONS 206.2.1 AND 206.2.2 OF ADAAG SITE NOTES 1. THIS SITE PLAN IS FOR REFERENCE ONLY -REFER TO CIVIL FOR SITE DIMENSIONAL CONTROL. 2. REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR SIDEWALKS AND ACCESSIBLE ROUTE THROUGHOUT SITE, FENCING, GATE LOCATIONS AND DETAILS. 3. REFER TO MEP FOR ELECTRICAL TRANSFORMER LOCATIONS. 4. DEVELOPMENT AND USE OF THIS SITE MUST CONFORM WITH ALL APPLICABLE CODES AND ORDINANCES. 5. ALL NEW OR RELOCATED UTILITIES WILL BE PLACED UNDERGROUND UNLESS NOTED OTHERWISE. 6. STRUCTURES AND LANDSCAPING WITHIN A TRIANGLE MEASURED BACK 15'-0" FROM THE PROPERTY LINE AND 20'-0" ALONG THE PROPERTY LINE ON EACH SIDE OF THE DRIVEWAY ENTRANCES WILL BE MAINTAINED AT A MAXIMUM HEIGHT OF 2'-6". 7. ANY LIGHTING WILL BE PLACED SO AS TO DIRECT LIGHT AWAY FROM RESIDENTIAL DISTRICTS AND WILL NOT EXCEED ONE- FOOT CANDLE AT THE PROPERTY LINE, UNLESS REQUIRED BY LOCAL ORDINANCE TO BE MORE. NO NOISE, ODOR OR VIBRATION WILL BE EMITTED AT ANY LEVEL EXCEEDING THE GENERAL LEVEL OF NOISE, ODOR OR VIBRATION EMITTED BY USES IN THE AREA OUTSIDE OF THE SITE. REFER TO MEP DRAWINGS FOR LOCATIONS. 8. OWNERS OF PROPERTY ADJACENT TO PUBLIC RIGHTS-OF-WAY SHALL HAVE RESPONSIBILITY FOR MAINTAINING ALL LANDSCAPING LOCATED IN THE RIGHTS-OF-WAY, IN ACCORDANCE WITH APPROVED PLANS. 9. AFTER FINAL APPROVAL THE PROJECT WILL BE INSPECTED FOR ZONING COMPLIANCE DURING CONSTRUCTION AND PRIOR TO OCCUPANCY. THE CONTRACTOR IS TO NOTIFY THE GOVERNING AUTHORITY PRIOR TO OCCUPANCY TO ARRANGE FOR INSPECTIONS. 10. ALL ROOFTOP EQUIPMENT AND SATELLITE DISHES SHALL BE SCREENED TO THE HEIGHT OF THE TALLEST EQUIPMENT. 11. ALL SERVICE AREAS SHALL BE SCREENED TO CONCEAL TRASH CONTAINERS, GAS METERS, LOADING DOCKS, TRANSFORMERS, BACKFLOW PREVENTERS AND OTHER MECHANICAL OR ELECTRICAL EQUIPMENT FROM EYE LEVEL ADJACENT TO ALL PUBLIC STREETS. 12. BARBED, RAZOR, OR CONCERTINA WIRE (OR SIMILAR) SHALL NOT BE USED ON THIS SITE WHERE VISIBLE FROM PUBLIC STREETS OR ADJACENT RESIDENTIAL AREAS. 13. POOLS, SPAS AND/OR LANDSCAPE TO BE UNDER SEPARATE SUBMITTAL AND PERMIT. 14. SIDEWALK SLOPES SHALL NOT EXCEED 5%, CROSS SLOPES NOT TO EXCEED 2% (REFER TO CIVIL) 15. THE EXIT DISCHARGE SHALL BE ILLUMINATED AND PROVIDED WITH BACK-UP POWER. FIRE DEPARTMENT NOTES T PROPERTY LINE SETBACK LINE TRANSFORMER LOCATION GENERAL REQUIREMENTS 1.FIRE DEPARTMENT FINAL INSPECTION REQUIRED PLEASE SCHEDULE ALL FIELD INSPECTIONS AT LEAST 48 HOURS IN ADVANCE. INSPECTIONS CANCELED AFTER 1 P.M. ON THE DAY BEFORE THE SCHEDULED DATE WILL BE SUBJECT TO A REINSPECTION FEE. CALL BOZEMAN FIRE DEPARTMENT INSPECTION SCHEDULING AT (XXX) XXX-XXXX 2.AN APPROVED VEHICLE STROBE DETECTOR SYSTEM, WITH KNOX BOX KEYSWITCH OVERRIDE, SATISFACTORY TO THE FIRE MARSHAL SHALL BE PROVIDED ON ALL VEHICLE MAIN ENTRY AND EMERGENCY ENTRY POINTS TO THE BUILDING. 3.SEE FIRE ACCESS PLANS FOR ADDITIONAL NOTES. ASSUMED PROPERTY LINEA.P.L. * ACCESSIBLE ENTRY SITE ENTRY IN COMPLIANCE WITH 2010 ADA SECTIONS 206.4.1 OF ADAAG. RESTRICTED ENTRANCES ALSO ACCESSIBLE IN COMPLIANCE WITH 206.4.7 OF ADAAG ✳FIRE SPRINKLER RISER ROOM (F.S.R.R.) #BUILDING NUMBER 1 PARKING SPACES PER BAY MIRRORED MIRRORED BUILDING CONDITION REF. SHEETS A4.10 ANSI TYPE 'A' ANSI UNIT NOT APPLICABLE FOR THIS SITE AS PER IBC 1108.6.2.2.1 ALL BUILDINGS NFPA 13R FIRE SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH 2021 IBC SECTION 903.3.1.2 F.D.C FIRE DEPARTMENT CONNECTION F. H FIRE HYDRANT ARCHITECTS, L.P.5339 ALPHA ROAD · SUITE 300 · DALLAS · TX 75240P: (972) 701.9636 · F: (972) 701.9639HUMPHREYS PARTNERS&DALLAS · CHARLOTTE · CHICAGO · DENVER · NEW ORLEANS · NEW YORK NEWPORT BEACH · ORLANDO · SCOTTSDALE · CHENNAI · HANOILONDON · MONTEVIDEO · MEXICO CITY · TORONTOwww.humphreys.comThe architectural works depicted herein are the sole property of Humphreys & Partners Architects, L.P. and may not be constructed or used without its express written permission. No permission to modify or reproduce any of the architectural works, including without limitation the construction of any building, is expressed or should be implied from delivery of preliminary drawings or unsealed construction drawings. Permission to construct the building depicted in sealed construction drawings is expressly conditioned on the full and timely payment of all fees otherwise due Humphreys & Partners Architects, L.P. and, in the absence of any written agreement to the contrary, is limited to a one-time use on the site indicated on these plans. © by Humphreys & Partners Architects, L.P. All Rights Reserved Designed by: SHEET CONTENTS SHEET NO. Drawn by: Architect of Record: Issue for Pricing / Bidding: Issue for Permit Application: Issue for Construction: Date Plotted: A0.20 SITE PLAN BRIDGER LAND GROUPBLOCK 14 APARTMENTSJY HPA #21135 HPA 02/03/2023 02/03/2023 100% DD SETVince Chupka 2022 BOZEMAN, MTRevisions # DATE COMMENTS 1/16" = 1'-0"1 SITE PLAN N