Loading...
HomeMy WebLinkAbout038 Lighting PlanTC OS OS OS GENERAL NOTES A. COMPLY WITH LATEST ADOPTED NEC AND APPLICABLE CODES/STANDARDS. B. SHARED NEUTRALS ARE NOT ALLOWED FOR SINGLE PHASE BRANCH CIRCUITS. MECHANICAL 102 STORAGE 103 LOBBY 101 DRIVE-UP TELLER 104 RESTROOM 105 CA1 CA1 CA1 CA1 CA1 CA1 CA1 CA1 CA1 CA1 CA1 CA1 WS2E WS2E OS A1 A1 A2E A2 A2 D1 D1 D1 D1 C1 1 2 3 4 A B 1111 2 P1-6 2 2 P1-12 3 4 P1-14 LIGHTING CONTACTOR CABINET PANEL P1 E003 3 P1-16 3 3 P1-18 6 WS2E WS2E 25P1-8 WATTSTOPPER PW-200$OS TYPE MANUFACTURER DESCRIPTION WALL MOUNTED DUAL RELAY PASSIVE INFRARED (PIR) TECHNOLOGY WALL SWITCH OCCUPANCY SENSOR. SET OFF DELAY TO 30 MINUTES AND SENSITIVITY TO MAX. SET FOR AUTO ON. FOR LIGHTING AND EXHAUST FAN. LIGHTING CONTROL SCHEDULE NOTES: 1. CONTRACTORS WORK TO INCLUDE ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. 2. SUBMIT SHOP DRAWINGS FOR ALL SENSORS, ROOM CONTROLLERS AND LOW VOLTAGE SWITCHES. 3. FIELD VERIFY EXACT LOCATION OF EACH SENSOR. LOCATE PER MANUFACTURER'S RECOMMENDATIONS. CEILING SENSORS SHALL BE INSTALLED A MINIMUM OF 5 FT FROM SUPPLY OR RETURN AIR DIFFUSERS. 4. ALL CONTROLS SHALL BE FULLY ADJUSTED AND COMMISSIONED AS RECOMMENDED BY THE MANUFACTURER. CEILING MOUNTED DUAL TECHNOLOGY LINE VOLTAGE OCCUPANCY SENSOR WITH 1,000 FT COVERAGE. DT-355 SET OFF DELAY TO 30 MINUTES AND SENSITIVITY TO MAX WATTSTOPPER DT-355OS REVISIONS 8/15/2022 10:16:19 AM LIGHTING PLAN E201 08.11.2022 © 2022 | ALL RIGHTS RESERVED SITE REVIEW SET DESIGNED BY | MAEHL DRAWN BY | GALLI DOWNTOWN BOZEMANSTOCKMAN BANK801 W Main Street | Project# SBDBZN_200 | L:\StockmanBank\SBDBZN_200 PROJECT# | SBDBZN_200 #KEYNOTES 1/4" = 1'-0"E201 1 FIRST FLOOR LIGHTING PLAN NOTES: 1) DRIVE UP LIGHT. ON-BOARD OCCUPANCY SENSOR TO BE PROGRAMMED TO DIM LIGHT FIXTURES TO 50% WHEN OCCUPANCY IS NOT DETECTED. FIXTURES TO BE PROGRAMMED AS ALL ON/ALL OFF VIA TIME CLOCK. SEE DETAIL 3/E005. 2) DRIVE UP LIGHT AT ATM. FIXTURES TO BE PROGRAMMED AS ALL ON/ALL OFF VIA TIME CLOCK. SEE DETAIL 3/E006. 3) PROVIDE THREADED HUB AND HANDHOLES IN POLE AT +18FT FOR SECURITY CAMERA WHERE APPLICABLE. 20' POLE LIGHTING FIXTURE SCHEDULE TYPE FIXTURE LIGHT SOURCE NOTESDESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING VOLTAGE VA LAMP TYPETYPE HEIGHT A1 2x2 LED LAY-IN FIXTURE, 0-10V DIMMING LITHONIA 2ALL2 40L MVOLT EZ1 LP835 RECESSED - 120 V 35.00 LED A2 2x4 LED LAY-IN FIXTURE, 0-10V DIMMING LITHONIA 2ALL4 48L MVOLT EZ1 LP835 RECESSED - 120 V 40.00 LED A2E 2x4 LED LAY-IN FIXTURE W/ BI-LEVEL DRIVER EM BATTERY LITHONIA 2ALL4 48L MVOLT SLD LP835 EL14L RECESSED - 120 V 40.00 LED C1 LED STRIP LITHONIA ZL2N L48 3000LM MDD MVOLT 35K 80CRI WH SURFACE 120 V 42.00 LED CA1 CANOPY LIGHT, BI-LEVEL DIMMING, INTEGRATED OCC SENSOR LITHONIA DSXSC LED 30C 700mA 40K T5W MVOLT SRM PIR SURFACE - 120 V 67.00 LED 1,2 D1 6" LED DOWNLIGHT, 0-10V DIMMING GOTHAM EVO-35/20-6AR-MD-LD-MVOLT RECESSED - 120 V 23.00 LED PL1 SINGLE HEAD POLE LIGHT LITHONIA DSX1 LED P2 40K TFTM MVOLT RPA PIRH DLL127F1.5JU DBLXD, POLE RSSDM19AS VD DBLXD POLE 20' 208 V 70.00 LED 3 WS2E EXTERIOR WALL SCONCE LITHONIA DSXW2 LED 20C 700 40K T2M MVOLT DBLXD PE ELCW SURFACE SEE ARCH ELEV 120 V 47.00 LED 1. PROVIDE 120V CONNECTION TO DRIVE UP LANES OPEN/CLOSED SIGN BY OTHERS. PROVIDE SWITCHES AS SHOWN. REFER TO ARCHITECTURAL DRAWING ELEVATIONS FOR ADDITIONAL INFORMATION. 2. PROVIDE 120V CONNECTION TO ATM SIGNAGE. SIGN SHALL REMAIN UNSWITCHED. COORDINATE LOCATION WITH SIGNAGE PROVIDER. REFER TO ARCHITECTURAL DRAWING ELEVATIONS FOR ADDITIONAL INFORMATION. 3. SWITCHES FOR OPEN/CLOSED SIGNS. 4. PROVIDE FAN-RATED WALL OCCUPANCY SENSOR SWITCH. CONNECT WITH EXHAUST FAN EF-1. REFER TO DRAWING E301 FOR ADDITIONAL INFORMATION. 5. PROVIDE SEPARATE TIME CLOCK FOR THIS CIRCUIT, TORK LC200 OR EQUIVALENT. INSTALL IN BASEMENT MECHANICAL 102 ROOM AS SHOWN. 6. ROUTE CIRCUIT TO PANEL VIA CONTACTOR CONTROLS IN MECHANICAL ROOM.