034 Electrical Details
UNDERGROUND METAL WATER PIPE #4 AWG CU BUILDING STEEL BOND GAS PIPING PER NEC FACP GROUND BAR SECURITY SYSTEM PHONE DEMARC #6 AWG GND PVC SLEEVE UL LISTED TERMINATION UFER: CONCRETE-ENCASED ELECTRODE SHALL BE #4 AWG BARE COPPER CONDUCTOR, STEEL REINFORCED BAR OR ROD NOT LESS THAN 1/2" DIAMETER AND AT LEAST 20 FT LONG. LOCATE IN BUILDING FOUNDATION WALL OR FOOTING LISTED CONNECTIONS MADE WITHIN 5 FT OF POINT OF ENTRANCE OF PIPE AND PRIOR TO WATER METERING. APPLIES TO DOMESTIC WATER AND FIRE SPRINKLER RISER. 1/4" x 2" x 12" COPPER GROUND BUSBAR WITH INSULATED STANDOFFS. ELECTRICAL BUILDING DISCONNECT N G GROUND SIZE FOR THIS PROJECT: GND ELECTRODE - #3/0 AWG BOND TO BLDG STEEL - #3/0 AWG NOTE: SEE POWER PLANS AND RISERS FOR EGC AND NEUTRAL SIZING. 1 1 2 2 WALL MOUNTING BRACKET TERMINATE WITH COMPRESSION LUGS INSULATED GROUND CONDUCTOR TO RACK EQUIPMENT PIECE INSULATED BUSHING EXOTHERMIC WELD GROUNDING BONDING CONDUCTOR SEE PLAN FOR SIZE INSULATED GROUND CONDUCTOR FROM 'TMGB' OR TO NEXT 'TGB' GROUND LUG BOLTED TO GROUND BUS POLE BASEDIAMETERPROJECT ANCHOR BOLTS ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND ONE BELOW BASE FLANGE). GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE. HAND FINISH. TEMPLATE TO BE FURNISHED BY POLE MANUFACTURER. REINFORCED CONCRETE BASE, BY ELECTRICAL CONTRACTOR SEE SITE PLAN FOR BRANCH CIRCUIT WIRING EDGE OF CURB OR PAVED AREA EDGE OF SIDEWALK BASE COVER #3 TIES "B" 1 1/2" MIN. FINISH GROUT 45 DEGREE CHAMFER BUSH CONDUIT ENDS FINISHED GRADE LINE ANCHOR BOLTS TO BE FURNISHED BY POLE MANUFACTURER HAND HOLE PROVIDE FUSE(S) IN CIRCUIT TO BALLAST. FUSE SIZE AS REQUIRED BY LUMINAIRE MANUFACTURER 1'-7" LAP 3 " C L R VERTICAL BARS #3 TIES @12" POLE HEIGHT 20' OR LESS 30' OR LESS 40' OR LESS POLE BASE DIAMETER VERTICAL BARS DEPTH BELOW GRADE RESTRAINED DEPTH BELOW GRADE UNRESTRAINED "A" "B""C""C1" "20" 5-#5 4'-6" 6'-0" "24" 6-#6 5'-6" 7'-0" "30" 8-#6 6'-6" 9'-0" (MIN. 3" LARGER THAN OUTER MOST PORTION OF BASE COVER) NOTE: PROVIDE 8' OF #6 AWG BARE COPPER WIRE WITHIN POLE BASE AND TIE TO VERTICAL/HORIZONTAL BARS AND BOND TO POLE AS REQUIRED. UNRESTRAINED AT BASE NO RIGID SURFACE AT GROUNDLINE "A"MIN3" "C1"18" MINMIN6" 12" MIN 36" MIN 2" 1 1/2" BOND #6 AWG BARE COPPER TO LIGHT POLE #6 AWG BARE COPPER GROUND WIRE 3/4" X 8' COPPER CLAD GROUND ROD PROVIDE 10"X10"X4" HOFFMAN JUNCTION BOX J-BOX 3/4" EMT C W/PULLSTRING LAY-IN CEILING STUB CONDUIT OUT ABOVE ACCESSIBLE CEILING INSTALL INSULATED THROAT BUSHING 1/2" EMT CONDUIT W/PULLSTRING CARD READER/ KEYPAD FINISHED FLOOR NOTE: 1. FIRE SEAL CONDUIT PENETRATION TO MAINTAIN RATING OF WALL WHERE APPLICABLE. 2. STUB OUT ALL CONDUITS AND INSTALL JUNCTION BOX ON SECURE SIDE OF DOOR WHERE APPLICABLE. POWER TRANSFER CONNECTION DOOR POSITION SWITCH 1 2 3 654 7 8 9 0*# WALL PROVIDE 4" SQ 2-1/8" DEEP BOX, 1-GANG MUD RING. PROVIDE DEVICES, DEVICE PLATE AND CABLING PER DIVISION 27 SPECIFICATION. 1" C. TYPICAL STUB CONDUIT OUT ABOVE ACCESSIBLE CEILING. INSTALL INSULATED THROAT BUSHING. FIRE SEAL CONDUIT PENETRATION TO MAINTAIN RATING OF WALL WHERE APPLICABLE. TYPICAL LAY-IN CEILING 2" WIDE J-HOOKS (BLINE BCH OR ERICO CABLE CAT) SUPPORTED TO STRUCTURE EVERY 3-4 FT. CABLES NOTE: VERIFY EXACT WALL TYPES WITH ARCHITECTURAL DRAWINGS. DRAWING IS INTENDED FOR GENERAL REFERENCE; ALL REQUIRED EQUIPMENT AND SUPPORTS NOT SHOWN. JACKS (COLOR CODED FOR SERVICE TYPE) TYPED LABEL BEHIND PLASTIC COVER TYPED LABEL BEHIND PLASTIC COVER RISER DIAGRAM IS A GUIDELINE AND DOES NOT INCLUDE ALL PARTS AND EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION. CONTRACTOR SHALL COMPLY WITH DIVISION 27 SPECIFICATIONS AND SHALL COORDINATE WITH OWNER ON EXACT INSTALLATION REQUIREMENTS. NUMBER OF CAT 6 CABLES VARY AT WORKSTATION JACK LOCATIONS. SEE SPECIAL SYSTEMS SHEETS FOR WORKSTATION JACK LOCATIONS AND TOTAL NUMBER OF CABLES TO BE PULLED TO EACH JACK. COORDINATE WITH OWNER FOR VOICA/DATA LABELING. 1. 2. 3. VOICE/DATA RISER GENERAL NOTES: TYPICAL WORKSTATION 2RMS WIRE MANAGER (TYP OF THIS TYPE) QUANTITY VARIES, UTP, 4-PAIR CAT 6 48 PORT PATH PANEL (TYP OF THIS TYPE) WALL MOUNTED RACK RISER DIAGRAM IS A GUIDELINE AND DOES NOT INCLUDE ALL PARTS AND EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION. CONTRACTOR SHALL COMPLY WITH DIVISION 27 SPECIFICATIONS AND SHALL COORDINATE WITH OWNER ON EXACT INSTALLATION REQUIREMENTS. NUMBER OF CAT 6 CABLES VARY AT WORKSTATION JACK LOCATIONS. SEE SPECIAL SYSTEMS SHEETS FOR WORKSTATION JACK LOCATIONS AND TOTAL NUMBER OF CABLES TO BE PULLED TO EACH JACK. COORDINATE WITH OWNER FOR VOICA/DATA LABELING. 1. 2. 3. VOICE/DATA RISER GENERAL NOTES: TYPICAL WORKSTATION 2RMS WIRE MANAGER (TYP OF THIS TYPE) QUANTITY VARIES, UTP, 4-PAIR CAT 6 48 PORT PATH PANEL (TYP OF THIS TYPE) WALL MOUNTED RACK REVISIONS 8/15/2022 10:15:55 AM ELECTRICAL DETAILS E002 08.11.2022 © 2022 | ALL RIGHTS RESERVED SITE REVIEW SET DESIGNED BY | CHAN DRAWN BY | CHAN DOWNTOWN BOZEMANSTOCKMAN BANK801 W Main Street | Project# SBDBZN_200 | L:\StockmanBank\SBDBZN_200 PROJECT# | SBDBZN_200 NOT TO SCALEE002 1 BUILDING GROUNDING ELECTRODE SYSTEM DETAIL NOT TO SCALEE002 2 'TGB'/'TMGB' GROUNDING BUSBAR DETAIL NOT TO SCALEE002 3 SITE POLE BASE DETAIL NOT TO SCALEE002 4 SECURITY DOOR ROUGH-IN DETAIL NOT TO SCALEE002 5 VOICE/DATA ROUGH-IN DETAIL NOT TO SCALEE002 6 Voice/Data Comm Riser Detail