Loading...
HomeMy WebLinkAbout028 Landscape Details2L201BIKE RACK 3/4"=1'-0"3'-078"1'-714"1 5/8" x 18"WALL METALTUBEFINISH GRADESECTIONCONCRETEISOMETRICNOTES:1.BIKE RACK TO BE MODEL: MBR500 SERIES, SURFACE MOUNTED AS MANUF. BY MAGLIN,WWW.MAGLIN.COM OR MADRAX, WWW.MADRAX.COM. POWDER COATED.2.SURFACE MOUNT BIKE RACKS ACCORDING TO MANUF.'S SPECIFICATIONS.3 EA 0.563"DIA. HOLE,TYP.ELEVATIONPLANPLANENLARGEMENT4.50" DIA, TYP.3L201MONUMENT SIGN SCALE = 3/4"=1'-0"3"R12"2"R1 2"3'-4"6"13"24"10"2'-8" 4'-234" 4'-0"WALL SECTIONRADIUS CAP PLAN VIEW#4 8" DOWEL EPOXY ADHERED1" INTO STONE AND CENTERING INWALL (2) PER CAP PIECE WITH 3" CLEARSLOPE CAP BACKCONCRETE CAPTO MATCHBUILDING COLORKERF CUT THEUNDERSIDE OF BOTHEDGES OF CONC FORWATER CONTROL34" CHAMFER ONCORNER OFSTONES18" MORTAR SEAMSPLIT FACE CMU TO MATCH BUILDING12" PVC WEEP HOLE 10' O.C.#5 REBAR VERT. @ 12" O.C. WITH2'-0" DOWEL IN HEEL OF WALL#4 REBAR HORZ. @ 12" O.C. CONT.(4) #4 REBAR CONT.NOTE:1.PROVIDE 2" CLEAR MIN. ON ALL REBAR.2.SLOPE CAP 14" PER FOOT TOWARDS PAVING.3.SEE STRUCTURAL FOR REBAR LAP LENGTHS3"UNDISTURBED NATIVE GRAVEL ORENGINEERED FILL PLACED ONUNDISTURBED NATIVE GRAVEL1'-4"3/4" CHAMFERNON ILLUMINATEDSIGN, NOT IN CONTRACTBRICK 1/2" CORBELBRICK B16" CMU REINFORCED JOINTS WITH #9 LADDER WIREINSTALL #4 VERTS @ 24". ADHESIVE SITE DOWELSWITH 4 12" EMBEDMENTTHROUGH WALLFLASHING WITH 12" DRIP EDGEWEEP/VENTSWRAP BRICK AROUND ENDS OF WALL ANDON BOTH SIDES OF WALL2'-0" 1'-2"1'-5 1/2"1'-512"CUT LINEAR CAPSTO FIT RADIUSCONDUIT SEE ELECTRICALTREE ROOT ZONEINSTALL 10' BEYONDCANOPY DRIP LINEUNLESS OTHERWISENOTED ON PLANNOTES:1.THE TYPICAL TREE PROTECTION ZONE SHALL BE THE WIDTH OF THE BOULEVARD ANDTHE DIMENSION SHOWN ON PLAN.2.FENCE THE TREE PROTECTION ZONE (TPZ) WITH FENCING TO PREVENT WOUNDS TO THETREE AND SOIL, AND COMPACTION WITHIN THE ROOT ZONE. POST THE FENCE WITH ASIGN STATING: “TREE PROTECTION ZONE – KEEP OUT”.3.SHOULD IT BE NECESSARY TO TRENCH WITHIN THE TPZ ALL TRENCHES SHALL BE HANDDUG. NO ROOTS LARGER THAN TWO INCHES (2”) SHALL BE CUT UNLESS NO OTHERALTERNATIVE IS FEASIBLE. CONSULT CITY ARBORIST IS LARGE ROOTS AREENCOUNTERED4.THE MINIMUM DISTANCE BETWEEN AN OPEN TRENCH AND ANY TREE SHALL BE TEN FEET(10’) FROM THE TRUNK OF THE TREE.5.AT NO TIME SHALL ANY EQUIPMENT, MATERIALS, SUPPLIES OR FILL SOIL BE ALLOWED INTHE TREE PROTECTION ZONE UNLESS NECESSARY.6.DO NOT REMOVE TREE PROTECTION-ZONE FENCING, EVEN TEMPORARILY, TO ALLOWDELIVERIES OR EQUIPMENT ACCESS THROUGH THE PROTECTION ZONE.7.TEMPORARY ACCESS IS ONLY PERMITTED SUBJECT TO PREAPPROVAL IN WRITING BYCITY ARBORIST.TREEPROTECTIONSIGNAGE3-4' CHAINLINKEXISTING TREETREE PROTECTION FENCE SCALE: 1/2"=1'-0"5L201TREE STAKES AND TIES AS SPECIFIED.STAKES SHALL NOT PENETRATE ROOTBALL.MULCH AS SPECIFIED. PULLMULCH AWAY FROM TRUNK.PLANTING DEPTH AS SPECIFIED.COMPLETELY REMOVE ROOTBALLWIRE AND BURLAP CONTAINMENTMATERIAL FROM ROOTBALL.NOTES:1.STAKING AND TREE WRAPPING IS NOT MANDATORY. HOWEVER, THE CONTRACTOR SHALL REPLACEANY UN-STAKED OR UNWRAPPED TREE WITHOUT QUESTION IF DIRECTED TO DO SO AT ANY TIMETHROUGH COMPLETION OF WARRANTY PERIOD.2.CREATE A SAUCER AROUND TREES IN MEADOW AREAS TO RETAIN IRRIGATION WATER.USE PROPER PRUNING TECHNIQUES TOREMOVE DEAD OR BROKEN LIMBS, ANDCOMPETING APICAL LEADERS.EXCAVATE HOLE:WIDTH = 3 x DIA. OF ROOTBALLDEPTH = HEIGHT OF ROOTBALLTREE PLANTING 1/4" = 1'-0"FINISH GRADE - SEE CIVIL.CONDITIONS VARY - SEE SITEPLAN AND CIVIL3' MIN.3'-6" MIN.4'14" X 5" X 6' DIA.BORDER KINGMANUFACTUREDBY BORDERCONCEPTS, INC.,STEEL EDGING,GALVANIZEDFINISH.LAWN APPLICATION4L201SIGN PLAN 1/4" = 1'-0"1L2014'-914"17'-612"4'-914"CENTERLINECENTERLINE CENTERLINE1'-0"WALL CAP, TYP135°135°SIGN - FOR VISUALIZATION ONLYSEE DETAILS FOR DIMENSIONS AND MATERIALSPERFORMANCE IRRIGATION NOTES:1.CONTRACTOR IS TO DESIGN AND INSTALL IRRIGATION SYSTEMS ANDCONNECT TO THE EXISTING IRRIGATION SYSTEM MAINLINE PIPING WHERENOTED ON THE PLANS. SEE PLANS FOR GENERAL AREAS OF EACHSUB-SYSTEM. WATER AND POWER POINT OF CONNECTIONS WITHIN ANDTHROUGH THE NEW AND EXISTING BUILDING2.IRRIGATION SYSTEMS TO BE UNDERGROUND AUTOMATIC IRRIGATIONSYSTEM TO PROVIDE ADEQUATE WATER FOR ALL PLANT MATERIAL ASSHOWN ON PLANTING PLANS. INSTALL MAINLINES & LATERAL LINE INUNDERGROUND TRENCH. INSTALL MANUAL DRAINS AT LOW POINTS ANDAIR RELIEF VALVES AT HIGH POINTS ALONG MAINLINE. INSTALL QUICKCOUPLERS AT END OF MAINLINE AND ISOLATION VALVES DOWNSTREAMOF MAINLINE TEES AND AT DRIVEWAYS.3.ROUTING OF PIPING IS CONCEPTUAL. COORDINATE ACTUAL ROUTES FORSLEEVES AND PLANTING (LAWN) REPAIR.4.COORDINATION OF DESIGN TO BE WITH OWNER FOR EXACT LOCATION.5.CONTRACTOR TO VERIFY AVAILABLE GALLONAGE AND PRESSURE.DESIGN IRRIGATION SYSTEM BASED UPON AVAILABILITY.6.PROPOSED SHRUB & PERENNIAL PLANTERS SHALL BE WATERED BYIN-LINE EMITTER DRIP WITH DRIP ZONE CONTROL KIT PROVIDE PVCLATERALS TO BEDS AND CONNECT TO DRIP LINE AS SPECIFIED.7.TURF AREAS SHALL BE WATERED BY SPRAY HEADS AS DETAILED ANDSPECIFIED WITH AUTOMATIC CONTROL VALVE. SPRAY HEADS TO BE ONSEPARATE ZONES THAN DRIP LINE ZONES. PROVIDE HEAD TO HEADCOVERAGE IN TURF AND FESCUE AREAS.8.CONTRACTOR SHALL PROVIDE SLEEVING FOR PIPE BELOW PAVEMENT.SLEEVE AS . SUPPLY ONE EXTRA SLEEVE WITH EACH MAINLINE SLEEVEFOR CONTROL WIRES. COORDINATE SLEEVE INSTALLATION WITH OTHERTRADES AND OTHER PROJECTS. BORE UNDER EXISTING SIDEWALKS ASREQUIRED TO EXTEND DOWN-SIZED IRRIGATION TO MAINLINE.9.IRRIGATION SYSTEM SHALL BE INSTALLED IN STRICT ACCORDANCE WITHALL PERTINENT CODES AND REGULATIONS, THE REFERENCEDSTANDARDS, AND THE MANUFACTURER'S RECOMMENDATIONS.10.IRRIGATION SYSTEM TO BE DESIGNED TO PREVENT OVER-SPRAY ONTOBUILDING AND PAVED SURFACES.11.ZONES TO BE DESIGNED WITH REGARD TO PLANT MATERIAL AND WINDAND SUN EXPOSURE TO ENSURE PROPER PLANT REQUIRED WATERCOVERAGE.12.PROVIDE ALL COMPONENTS REQUIRED FOR PROPER WINTERIZATION OFSYSTEM.13.PRIOR TO IRRIGATION MAINLINE TRENCH BACKFILL, CONTRACTOR TOCONTACT ARCHITECT FOR MAINLINE PRESSURE TEST.14.PROVIDE SCHEMATIC (INCLUDING ALL WATER SOURCES) PRIOR TOMATERIAL PURCHASE AND THEN FINAL LAYOUT AND SHOP DRAWINGS FORWRITTEN APPROVAL. SEE SUBMITTAL REQUIREMENTS FOR ADDITIONALINFORMATION.15.SEE DETAILS SHEET AND ALL PROJECT MANUAL SPECIFICATIONS.EXISTINGIRRIGATION NOTES:1.EXISTING IRRIGATION SYSTEMEXIST ON SITE. BOULEVARDIRRIGATION TO BE RETAINED ANDPRESERVED DURRINGCONSTRUCTION FOR EXISTINGTURF AND TREES. EXISTINGIRRIGATION IN PARKING LOT TO BEDEMOLISHED WITHIN LIMITS OFWORK. ALL NEW IRRIGATION ISTO BE CONNECTED TO EXISTINGDOMESTIC MAINLINE WITHVALVES. CONTROL IRRIGATIONWITH EXISTING CONTROLLERLOCATED IN THE SNOWLOADBUILDING.2.THE EXISTING IRRIGATIONSYSTEMS MAY EXTEND BEYONDTHE PROJECT LIMITS. AREASMUST REMAIN OPERATIONALDURING THE GROWING SEASON.PROVIDE TEMPORARYCONNECTIONS TO MAINTAINPLANTS TO REMAIN. ANYNEGLECTED PLANTINGS THAT DIEWILL BE THE RESPONSIBILITY OFTHE CONTRACTOR TO REPLACE.REPLACED PLANTINGS WILL BEEQUIVALENT IN QUANTITY,SPECIES, HEALTH AND MATURITY(UP TO 4" CAL. FOR TREES)3.REMOVE ALL EXISTING AT-GRADESYSTEM COMPONENTS(INCLUDING HEADS WITH JOINTS,VALVES, BOXES, ETC.) IN PROJECTDISTURBANCE AREAS ANDRETURN TO OWNER AT OWNERSDISCRETION. CAP AND ABANDONALL BELOW-GRADE PIPING NOTAFFECTED BY CONSTRUCTIONACTIVITIES.06.29.17 11:09 PM | L:\StockmanBank\SBDBZN_200\BIMCAD\LandArch\SBWF_L201.dwgL201LANDSCAPEDETAILSRUSHARBORIST COORDINATION 3/23/23RUSHDRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®PROJECT #|DOWNTOWN BOZEMAN STOCKMAN BANK 801 W MAIN STREET100% CONSTRUCTIONDOCUMENTS08.11.20222020PROJECT#11