HomeMy WebLinkAboutCommercialWaterServiceFixt Residential (2018 IRC) City of Bozeman Water Service Calculation Worksheet Project Address: Block 2, Lot 10, Nelson Meadows,Bozeman,MT Property Owner: oh My Gord, LLC General Contractor: Miller construction Permit Number: Proposed Water Meter Size: 3/4" UPC Table 610.3 Standard Design Water Supply Fixture Units Appliances and Fixtures Fixture Units #of Fixtures Total Bathtub or combo tub/shower (1/2"fill valve) 4.0 X = Bath Tub(3/4"fill valve) 10.0 X = Shower (per head) 2.0 X = Clothes washer 4.0 X = Dishwasher 1.5 X 1 = 1.5 Hose Bibb 2.5 X 1 = 2.5 Additional Hose Bibb (each) 1.0 X 1 = 1.0 Lavatory Sink 1.0 X 2 = 2.0 Kitchen Sink 1.5 X 2 = 3.0 Laundry Sink 1.5 X = Water closet [toilet] (1.6 GPF) 2.5 X 3 = 7.5 Bidet 1.0 X = Urinal (flushometer valve) Table Values* 1 = 20 Total Number of Fixture Units 37.5 Fixture Unit Tables for Determining Water Pipe & Meter Size Pressure Range—46-60 PSI Circle the length in feet to the farthest fixture & applicable service, meter& branch sizes below based on the total number of fixture units detailed above. Maximum Allowable Length in feet Meter& Supply& 60' 80' 100, 150' 200' Service Branches %11 %11 20 19 17 14 11 %11 ill 39 36 33 28 23 1" 1" 39 39 36 30 25 1'/4" 39 39 39 39 39 J N T. 1" 1%11 78 76 67 52 44 10951 E 0951PE 1'/2" 1'/4" 78 78 78 66 52 1" 1'h"/2" 85 85 85 85 85 11/2" 1'/2" 151 151 151 128 105 - 2" 1'/2" 151 151 151 150 117 1'/2" 2" 370 340 318 272 240 2" 2" 370 370 370 368 318 If count is over 370 fixtures, water demand does not meet table 610.4 and must be engineered by a registered Montana mechanical engineers design, signed and stamped. 04.29.20