HomeMy WebLinkAbout037_E1.0 Electrical CoverMISCELLANEOUS LEGEND
COMMUNICATION DEVICES
FIRE ALARM DEVICES
ESV
F
F
M
DSD
S
V
PP
C
J
PP
OS
OS
POWER DEVICES
M
T
R
F
F F
V
W
C
R
ELECTRICAL LEGEND
T
AS
F
F
F
FACP
LAA
FS
TS
PS
ARRP
ARMP
CO2
CO2
M
JJ
THERMOSTAT BY MC, ROUGH-IN BY EC
PAD MOUNTED UTILITY TRANSFORMER
NORMAL CIRCUIT CONCEALED IN WALL OR EXPOSED
UNDERGROUND OR BURIED CIRCUIT
HOMERUN TO ELECTRICAL PANEL
NUMBER OF HASH MARKS INDICATES NUMBER OF CURRENT CARRYING
CONDUCTORS. NO MARKS INDICATES TWO. GROUNDING CONDUCTOR NOT
SHOWN BUT SHALL BE INCLUDED IN ALL CONDUITS.
W/WITH
AC ABOVE COUNTER
EC ELECTRICAL CONTRACTOR
(E)EXISTING
(R)RELOCATED
(N)NEW DEVICE
C
BFG BELOW FINISHED GRADE
UC UNDER COUNTER
WP WEATHER PROOF
MC MECHANICAL CONTRACTOR
CEILING MOUNTED SPEAKER
REFER TO ELECTRICAL NOTES
COMBINATION WALL SPEAKER/ CLOCK UNIT
MANUAL PULL STATION
AUDIO/VISUAL HORN/STOBE DEVICE
VISUAL STROBE DEVICE
MAGNETIC DOOR HOLDER
SMOKE DETECTOR
HEAT DETECTOR
CARBON MONOXIDE DETECTOR
SPRINKLER CONNECTION, PRESSURE SWITCH
SPRINKLER CONNECTION, TAMPER SWITCH
SPRINKLER CONNECTION, FLOW SWITCH
SPRINKLER CONNECTION, LOW AIR ALARM
DUCT SMOKE DETECTOR
FIRE SMOKE DAMPER
FIRE ALARM CONTROL PANEL
FIRE ALARM REMOTE ANNUNCIATOR
ELEVATOR SHAFT VENT, CONNECT TO FIRE ALARM SYSTEM
VOICE DEVICE JACK, BOX INDICATES FLOOR MOUNTING
CABLE TV JACK
INTERCOM JACK
WALL MOUNTED SPEAKER
WALL MOUNTED VOLUME CONTROLLER
WALL CLOCK
DUPLEX RECEPTACLE SUBSCRIPT INDICATES TYPE:
DOUBLE DUPLEX RECEPTACLE, SUBSCRIPT ABOVE INDICATE TYPE
DUPLEX RECEPTACLE IN FLOOR BOX
DOUBLE DUPLEX RECEPTACLE IN FLOOR BOX
SIMPLEX RECEPTACLE
MOTOR CONNECTION
VARIABLE FREQUENCY DRIVE
MUSHROOM HEAD PUSH BUTTON
SIMPLEX RECEPTACLE IN FLOOR BOX
PHOTO CELL
WALL MOUNTED CLOCK HANGER/ POWER RECEPTACLE
CORNER WALL MOUNTED OCCUPANCY SENSOR
CEILING MOUNTED OCCUPANCY SENSOR, STYLE 1
CEILING MOUNTED OCCUPANCY SENSOR, STYLE 2
CEILING MOUNTED OCCUPANCY SENSOR, STYLE 3
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
COMBINATION STARTER/DISCONNECT SWITCH
WP WEATHERPROOF
GFCI GROUND FAULT CIRCUIT INTERRUPTER
AC ABOVE COUNTER
IG ISOLATED GROUND
TR TAMPER RESISTANT
WR WEATHER RESISTANT
FILLED CENTER INDICATES GFCI DEVICE
CO2 DETECTOR BY MC, ROUGH-IN BY EC
CONTACTOR
MANUAL MOTOR STARTER
SINGLE POLE SWITCH, SUBSCRIPT INDICATES TYPE:
P PILOT LIGHT
2 2 POLE
MC MOMENTARY CONTACT
3 3-WAY
4 4-WAY
K KEYED
D DIMMER
LV LOW VOLTAGE
T TIMER, 1 HOUR TIMER, MOTOR RATED FOR EXHAUST FANS
OS OCCUPANCY SENSOR
RELAY
1'-6"FINISHED CEILING
FINISHED FLOOR
COD
COD
TOD
44"74" TO TOP OF TRIMBOD
80" MINIMUM TO BOTTOM84" AFF TO BOTTOM OF DEVICE OR 6"BELOW CEILING TO TOP OF DEVICE,WHICHEVER IS LOWER.48"COD
AQUASTAT BY PLUMBING CONTRACTOR, WIRED BY EC.
AREA OF RESCUE ASSISTANCE -REMOTE STATION
AREA OF RESCUE ASSISTANCE -MASTER STATION
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
WM WIRE MOLD
GC GENERAL CONTRACTOR
GND GROUND
UG UNDER GROUND
BOD BOTTOM OF DEVICE
TOD TOP OF DEVICE
COD CENTER OF DEVICE
BOF BOTTOM OF FIXTURE
AUDIO SPEAKER DEVICE
CEILING MOUNTED AUDIO/VISUAL SPEAKER/STROBE DEVICE
CEILING MOUNTED AUDIO SPEAKER DEVICE
ADDRESSABLE INTERFACE DEVICE BY EC FOR FIRE/SMOKE DAMPERS
DUPLEX RECEPTACLE, CEILING MOUNTED. DEVICE AND COVER SHALL MATCH
CEILING FINISH
SPECIAL PURPOSE CONNECTION, BRACKET INDICATES WALL MOUNTING, BOX
INDICATES FLOOR MOUNTING
COMBINATION VOICE/ DATA DEVICE JACKS, BOX INDICATES FLOOR MOUNTING
208V SINGLE PHASE RECEPTACLE, CONFIGURATION NOTED ON PLANS
208V THREE PHASE RECEPTACLE, CONFIGURATION NOTED ON PLANS
OCCUPANCY SENSOR POWER PACK, BOX INDICATES WALL MOUNTING
JUNCTION BOX, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR
MOUNTING
ELECTRICAL PANEL - SEE PANEL SCHEDULES FOR MOUNTING CONFIGURATION
S
C
SSC
C
FSD
FAA
OS
OS
1
2
3
VFD
SD
HD
CO
PC PLUMBING CONTRACTOR
MISCELLANEOUS LEGEND
COMMUNICATION DEVICES
F
S
V
PP
C
J
PP
OS
OS
POWER DEVICES
M
T
R
F
F F
V
W
C
T
INTERIOR MOUNTING HEIGHTS
AS
ARRP
ARMP
CO2
CO2
M
JJ
THERMOSTAT BY MC, ROUGH-IN BY EC
PAD MOUNTED UTILITY TRANSFORMER
NORMAL CIRCUIT CONCEALED IN WALL OR EXPOSED
UNDERGROUND OR BURIED CIRCUIT
HOMERUN TO ELECTRICAL PANEL
NUMBER OF HASH MARKS INDICATES NUMBER OF CURRENT CARRYING
CONDUCTORS. NO MARKS INDICATES TWO. GROUNDING CONDUCTOR NOT
SHOWN BUT SHALL BE INCLUDED IN ALL CONDUITS.
W/WITH
AC ABOVE COUNTER
EC ELECTRICAL CONTRACTOR
(E) EXISTING
(R)RELOCATED
(N)NEW DEVICE
C CONDUIT
BFG
UC UNDER COUNTER
WP WEATHER PROOF
MC MECHANICAL CONTRACTOR
CEILING MOUNTED SPEAKER
COMBINATION WALL SPEAKER/ CLOCK UNIT
VOICE DEVICE JACK, BOX INDICATES FLOOR MOUNTING
CABLE TV JACK
INTERCOM JACK
WALL MOUNTED SPEAKER
WALL MOUNTED VOLUME CONTROLLER
WALL CLOCK
DUPLEX RECEPTACLE SUBSCRIPT INDICATES TYPE:
DOUBLE DUPLEX RECEPTACLE, SUBSCRIPT ABOVE INDICATE TYPE
DUPLEX RECEPTACLE IN FLOOR BOX
DOUBLE DUPLEX RECEPTACLE IN FLOOR BOX
SIMPLEX RECEPTACLE
MOTOR CONNECTION
VARIABLE FREQUENCY DRIVE
MUSHROOM HEAD PUSH BUTTON
SIMPLEX RECEPTACLE IN FLOOR BOX
PHOTO CELL
WALL MOUNTED CLOCK HANGER/ POWER RECEPTACLE
CORNER WALL MOUNTED OCCUPANCY SENSOR
CEILING MOUNTED OCCUPANCY SENSOR, STYLE 1
CEILING MOUNTED OCCUPANCY SENSOR, STYLE 2
CEILING MOUNTED OCCUPANCY SENSOR, STYLE 3
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
COMBINATION STARTER/DISCONNECT SWITCH
WP WEATHERPROOF
GFCI GROUND FAULT CIRCUIT INTERRUPTER
AC ABOVE COUNTER
IG ISOLATED GROUND
TR TAMPER RESISTANT
WR WEATHER RESISTANT
FILLED CENTER INDICATES GFCI DEVICE
CO2 DETECTOR BY MC, ROUGH-IN BY EC
CONTACTOR
MANUAL MOTOR STARTER
SINGLE POLE SWITCH, SUBSCRIPT INDICATES TYPE:
P PILOT LIGHT
2 2 POLE
MC MOMENTARY CONTACT
3 3-WAY
4 4-WAY
K KEYED
D DIMMER
LV LOW VOLTAGE
T TIMER, 1 HOUR TIMER, MOTOR RATED FOR EXHAUST FANS
OS OCCUPANCY SENSOR
RELAY
1'-6"FINISHED CEILING
FINISHED FLOOR
COD
COD
TOD
44"74" TO TOP OF TRIMBOD
80" MINIMUM TO BOTTOMAC = MINIMUM 4" ABOVE
BACKSPLASH TO BOTTOM
OF DEVICE.84" AFF TO BOTTOM OF DEVICE OR 6"BELOW CEILING TO TOP OF DEVICE,WHICHEVER IS LOWER.48"COD
AQUASTAT BY PLUMBING CONTRACTOR, WIRED BY EC.
AREA OF RESCUE ASSISTANCE -REMOTE STATION
AREA OF RESCUE ASSISTANCE -MASTER STATION
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
WM WIRE MOLD
GC GENERAL CONTRACTOR
GND GROUND
UG UNDER GROUND
BOD BOTTOM OF DEVICE
TOD TOP OF DEVICE
COD CENTER OF DEVICE
BOF BOTTOM OF FIXTURE
DUPLEX RECEPTACLE, CEILING MOUNTED. DEVICE AND COVER SHALL MATCH
CEILING FINISH
SPECIAL PURPOSE CONNECTION, BRACKET INDICATES WALL MOUNTING, BOX
INDICATES FLOOR MOUNTING
COMBINATION VOICE/ DATA DEVICE JACKS, BOX INDICATES FLOOR MOUNTING
SWITCHED DUPLEX RECEPTACLE, BOX INDICATES DEVICE LOCATED IN FLOOR BOX
208V SINGLE PHASE RECEPTACLE, CONFIGURATION NOTED ON PLANS
208V THREE PHASE RECEPTACLE, CONFIGURATION NOTED ON PLANS
OCCUPANCY SENSOR POWER PACK, BOX INDICATES WALL MOUNTING
JUNCTION BOX, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR
MOUNTING
ELECTRICAL PANEL - SEE PANEL SCHEDULES FOR MOUNTING CONFIGURATION
S
C
SSC
C
OS
OS
PC
1
2
3
VFD
PC PLUMBING CONTRACTOR
SECURITY SYSTEM DEVICES
MS
MS
KP
CCTV
MS
REX
CLOSED CIRCUIT CAMERA
KEY PAD
CEILING MOUNTED MOTION SENSOR
CORNER MOUNTED MOTION SENSOR
WALL MOUNTED MOTION SENSOR
REQUEST TO EXIT SENSOR
CR CARD READER
1
PROVIDE FUSE(S) IN CIRCUIT TO
BALLAST FUSE SIZE AS REQUIRED
BY LUMINAIRE MANUFACTURER
HAND HOLE
CONNECT GROUND TO POLE
LUG, GROUND LUG PROVIDED
WITH POLE
BUSH CONDUIT ENDS
1" CHAMFER
1 1/2" MIN. FINISH
GROUT
ANCHOR BOLT TO BE
FURNISHED BY POLE
MANUFACTURER
3-#3 TIES AT
TOP OF FORM
FINISH GRADE LINE
5 NO. 6 REBARS
BELOW GRADE
5 NO. 3 TIE RODS
REINFORCE CONCRETE
BASE BY GENERAL
CONTRACTOR 24"
ROUND
UNDISTURBED SOIL
SEE SITE PLAN FOR
BRANCH CIRCUIT WIRING
66"
24"
30"
EDGE OF CURB OR
PAVED AREA.
60"
MIN.
BASE COVER
PROJECT ANCHOR BOLTS ABOVE TOP OF BASE.
PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE
ABOVE AND BELOW BASE FLANGE) GROUT VOID
BETWEEN BASE FLANGE AND TOP OF CONCRETE,
HAND FINISH. TEMPLATE TO BE FURNISHED BY
POLE MANUFACTURER.ACE JOB 21BZ539412 N. BROADWAYSECOND FLOORBELGRADE, MT 59714406-388-3320COPYRIGHT 2019
11/29/2021 1:49:22 PME1.0
SITE PLAN REVIEW
1811TRINITY CHURCH ELECTRICAL COVERELECTRICAL SHEET LIST
E1.0 ELECTRICAL COVER
E1.3 MASTER ELECTRICAL SITE PLAN
E1.4 MASTER PHOTOMETRIC SITE PLAN
E1.5 PHASE I ELECTRICAL SITE PLAN
E1.6 PHASE I PHOTOMETRIC SITE PLAN
E1.7 SITE LIGHTING CUTSHEETS
LUMINAIRE SCHEDULE
CALLOUT MANUFACTURER MODEL MOUNTING
MOUNTING
HEIGHT LAMP
INPUT
WATTS VOLTS DESCRIPTION
C1 PATHWAY LIGHTING 4SFK 4SFL2X 8 4K E1 DA WL2 ES RECESSED CEILING 730 LUMEN LED 9 120 4" LED WET RATED DOWN LIGHT
S1 LITHONIA DSX1 LED P6 40K T4M 120 RPA PIRH SF * POLE 25'-0" 18,500 LUMEN LED 163 120 LED SITE LIGHT W/ TYPE 4 OPTICS.
S2 LITHONIA DSX1 LED P3 40K T4M 120 RPA PIRH SF * POLE 18'-0" 12,300 LUMEN LED 102 120 LED SITE LIGHT W/ TYPE 4 OPTICS.
S3 LITHONIA DSX1 LED P8 40K T4M 120 RPA PIRH SF * POLE 25'-0" 23,700 LUMEN LED 207 120 LED SITE LIGHT W/ TYPE 4 OPTICS.
S4 LITHONIA DSX1 LED P8 40K T2M 120 RPA PIRH HS SF * POLE 25'-0" 24,300 LUMEN LED 207 120 LED SITE LIGHT W/ TYPE 2 OPTICS AND HOUSE SIDE SHIELD.
S5 LITHONIA DSX1 LED P8 40K T2M 120 RPA PIRH SF * POLE 25'-0" 24,300 LUMEN LED 207 120 LED SITE LIGHT W/ TYPE 2 OPTICS.
S6 LITHONIA DSX1 LED P4 40K TFTM 120 RPA PIRH SF * POLE 18'-0" 15,800 LUMEN LED 125 120 LED SITE LIGHT W/ TYPE FORWARD THROW OPTICS.
S7 LITHONIA DSX1 LED P4 40K T2M 120 RPA PIRH SF * POLE 18'-0" 15,800 LUMEN LED 125 120 LED SITE LIGHT W/ TYPE 2 OPTICS.
W1 PATHWAY LIGHTING C95 W V 30 4 G2 L9 DW WL * * WALL 7'-6" 1500 LUMEN LED 24 120 6" LED CYLINDER WAL MOUNT W/ FORWARD THROW OPTIC
W2 PATHWAY LIGHTING C95 W V 30 4 G1 L9 DW WL * * WALL 9' 1500 LUMEN LED 24 120 6" LED CYLINDER WAL MOUNT W/ WALL WASH OPTIC
W3 PATHWAY LIGHTING C95 W V 10 4 G2 L9 DW WL * * WALL 7'-6" 530 LUMEN LED 8 120 6" LED CYLINDER WAL MOUNT W/ FORWARD THROW OPTIC
NOT TO SCALE1POLE BASE DETAIL
ISSUE DATE DESCRIP.MINISTRY CENTER701 North Ferguson Ave. Bozeman, MT 59718