Loading...
HomeMy WebLinkAbout013 C6.0 Civil DetailsPROJECT NO: DATE: ENGINEER: REVISIONS DATENO.DESC. SHEET OF 12 22002 January 6, 2023 ELCCOTTAGES AT BLACKWOOD GROVESBOZEMAN, MONTANABLOCK 14 CIVIL SITE PLANTAOMNNA RN GEO S EF SI NA LROP EINECOTE ETHAN L No. 60593PE ELICNES D01/06/2023 C6.0 CONSTRUCTION DETAILSWATER SERVICE LINE DETAIL2SCALE: NTS TYPICAL UTILITY TRENCH DETAIL1SCALE: NTS SANITARY SEWER SERVICE LINE DETAIL4SCALE: NTS SANITARY SEWER AND STORM DRAIN MANHOLE DETAIL6SCALE: NTS WATER SERVICE LINE FROM CURB STOP TO BUILDING (2" AND SMALLER)3 SCALE: NTS NYLOPLAST DRAIN BASIN DETAIL9SCALE: NTS NOTES 1.8-30" (200-750 mm) GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2.12-30" (300-750 mm) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3.DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS 4.DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC 5.FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM 6.TO ORDER CALL: 800-821-6710 A PART #GRATE/SOLID COVER OPTIONS 8" (200 mm)2808AG PEDESTRIAN LIGHT DUTY STANDARD LIGHT DUTY SOLID LIGHT DUTY 10" (250 mm)2810AG PEDESTRIAN LIGHT DUTY STANDARD LIGHT DUTY SOLID LIGHT DUTY 12" (300 mm)2812AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 15" (375 mm)2815AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 18" (450 mm)2818AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 24" (600 mm)2824AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 30" (750 mm)2830AG PEDESTRIAN AASHTO H-20 STANDARD AASHTO H-20 SOLID AASHTO H-20 INTEGRATED DUCTILE IRON FRAME & GRATE/SOLID TO MATCH BASIN O.D. GRATE / COVER TYPE VARIES PER BASIN. REFER TO PLAN SHEETS. VARIOUS TYPES OF INLET AND OUTLET ADAPTERS AVAILABLE: 4-30" (100-750 mm) FOR CORRUGATED HDPE WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE ASTM D2321 CLASS I OR II CRUSHED STONE OR GRAVEL AND BE PLACED UNIFORMLY IN 12" (305 mm) LIFTS AND COMPACTED TO MIN OF 90% TRAFFIC LOADS: CONCRETE DIMENSIONS ARE FOR GUIDELINE PUPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED GIVING CONSIDERATION FOR LOCAL SOIL CONDITIONS, TRAFFIC LOADING & OTHER APPLICABLE DESIGN FACTORS ADAPTER ANGLES VARIABLE 0°- 360° ACCORDING TO PLANS 18" (457 mm) MIN WIDTH A AASHTO H-20 CONCRETE SLAB 8" (203 mm) MIN THICKNESS SUMP DEPTH PER PLAN (18" TYPICAL) 4" (102 mm) MIN ON 8-24" (200-600 mm) 6" (152 mm) MIN ON 30" (750 mm) 12" (610 mm) MIN (FOR AASHTO H-20) INVERT ACCORDING TO PLANS 6" MIN. 18" MAX. DEPTH FINISH GRADE COMPACTED SUBGRADE STORM SWALE SECTION DETAIL7SCALE: NTS 20 : 1 M I N . & 3 : 1 M A X . S I D E S L O P E FINISH GRADE SWALE WITH 6" TOPSOIL AND SEED PER LANDSCAPE PLAN SANITARY SEWER CLEANOUT DETAIL5SCALE: NTS 11 MINIMUM PIPE BURIAL DEPTH PER PIPE MANUFACTURER RECOMMENDATION INVERT ACCORDING TO PLANS 15" 1 - 8" - 30" DOME GRATES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. 2 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL), N-12 HP, & PVC SEWER (4" - 24"). 3 - 8" - 30" DOME GRATES HAVE NO LOAD RATING (3) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE: 4" - 30" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL, ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35), PVC DWV (EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVC WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. NYLOPLAST INLINE DRAIN WITH FLAT GRATE DETAIL8SCALE: NTS REFERENCE: ADS NYLOPLAST DWG. NO. 7003-110-057 (1,2) INTERGRATED DUCITLE IRON FRAME & GRATE TO MATCH BASIN O.D. 8" DIA. PIPE ALL FINISH GRADE BETWEEN BUILDINGS TO SLOPE AWAY FROM FOUNDATIONS AT 20:1 MIN. SLOPE NOTE: MINIMUM LONGITUDINAL SWALE SLOPE TO BE >2% WITHIN 10 FEET OF BUILDINGS