Loading...
HomeMy WebLinkAbout012 C3.0 Utility Plan (1 of 2)8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S WSWSFIREFIREWSWSFIREFIREWSWSWSFIREFIRESSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDFIREIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGIRRIGSD SD SD SD SD SD SD FMFMFMFMFMFMFMFMFMFMFMFMFMFMFM8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12W 12WBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBP BP15S15S15S15S15S15S15S15S15S15S15S15S15S15S15S15S15S15S15S15S15SS S8W8W8WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8SPBPROPOSED 30.00'WATER & SEWEREASEMENT30.00' PUBLICUTILITYEASEMENT 15SD15SD15SD15SD15SD15SD15SD15SD15SD15SD15SD15SD15SD15SD 15SD 15SD 15SD 15SD 15SD 15SD 15SD15SD15SD15SD12SD12SD12SD15SD 15SD15SD15SD15SD15SD15SD15SD15SD15SD15SD30.00' PUBLICUTILITYEASEMENT  C3.0UTILITY PLAN(1 OF 2)12-01-2022SHEET NUMBERPROJECT CODEPROJECT ADDRESSARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS.DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ONDRAWING SHEET AND MAY NOT BE REPRODUCED OR USEDFOR OTHER PURPOSES WITHOUT WRITTEN PERMISSIONFROM ARCHITECT.NWBWEST PARKNEIGHBORHOODBLOCK 1LOT 1WEST PARKSUBDIVISIONPRELIMINARY106 EAST BABCOCK STREETSUITE 1ABOZEMAN, MT 59715SHEET NAMEPROJECT NAMEDRAWING REVISIONSDRAWING ISSUE DATEDRAWING ISSUED FORPHONE: (406) 582-898812/01/2022VAUGHN DRIVELAUREL PARKWAY 1.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THEMONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, 6TH EDITION DATED APRIL 2010(MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; AND THE PROJECTSPECIFICATIONS.2.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTERCONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER,AND/OR ENGINEER.3.ASPHALT, CONCRETE CURB, AND SIDEWALK SHALL BE SAW CUT OR NEAT CUT ASAPPROVED BY AGENCY AND/OR ENGINEER.4.ALL TEXT AND FEATURES SHOWN SHADED ARE EXISTING. SEE SHEET C1.0 FOR MORECOMPLETE DEPICTION OF EXISTING IMPROVEMENTS.5.THE LOCATION, DEPTH, AND SIZE OF THE EXISTING UTILITIES SHOWN ON THESE PLANS ISAPPROXIMATE. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, LOCATION, DEPTH, ANDSIZE OF THE UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELYRESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATEOR PROPERLY PROVIDE PROTECTION WHEN LOCATION IS KNOWN.6.ALL WATER VALVES OWNED AND OPERATED BY THE CITY OF BOZEMAN SHALL BE OPERATEDBY AUTHORIZED CITY OF BOZEMAN PERSONNEL ONLY.7.SEWER AND WATER CONNECTIONS SHALL BE PERFORMED BY A LICENSED PLUMBER.8.GENERAL CONTRACTOR TO COORDINATE DRY UTILITY AND IRRIGATION REQUIREMENTS.9.ALL SEWER SERVICES REFER TO COB STD DWG: 02730-210.ALL WATER SERVICES REFER TO COB STD DWG: 02660-1511.FIRE SERVICES REFER TO COB STD DWG: 02660-1312.INVERT ELEVATIONS OBTAINED FROM NORTON EAST RANCH SUBDIVISION CONSTRUCTIONDRAWINGS DATED 3/10/2022 BY C&H.GENERAL NOTES:EXISTING FORCE MAINEXISTING 8"SEWER MAINEXISTING 48" SSMHRIM = 4782.378" INV IN (E) = 4773.078" INV IN (S) = 4773.078 INV OUT (W) = 4772.87PROPOSED 8" SEWER MAINPLANS ON SEPARATEINFRASTRUCTURE SETPROPOSED 8" WATER MAINPLANS ON SEPARATEINFRASTRUCTURE SETEXISTING 12" WATER MAINEXISTING 15" SEWER MAINEXISTING SSMH-1RIM = 4782.048" INV IN (NW) = 4771.1115" INV IN (S) = 4776.4115" INV OUT (E) = 4770.89EXISTING 60" SSMH 5-1ARIM = 4783.088" INV IN (E) = 4771.4015" INV IN (S) = 4776.6715" INV OUT (M) = 4770.73EXISTING 48" WET WELL15" INV IN (W) = 4769.36EXISTING LIFTSTATION204010200SCALE IN FEETKnow what'sbelow.before you dig.CallRTHIS SITE HAS BEEN DESIGNED TO BE ACCESSIBLE TOINDIVIDUALS WITH DISABILITIES IN ACCORDANCE WITHTHE AMERICANS WITH DISABILITIES ACT.18-PLEX (C)FFE = 4786.00'18-PLEX (A)FFE = 4786.15'18-PLEX (B)FFE = 4787.63'12-PLEX (D)FFE = 4787.25'NOTES BY SYMBOL:INSTALL ± 26 LF OF 2" COPPER, TYPE K, FIRE SERVICE AT 6.5' MINIMUM DEPTH BURY DEPTHSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 29 LF OF 2" COPPER, TYPE K, ANNEALED DOMESTIC WATER SERVICE AT 6.5'MINIMUM BURY DEPTH. PIPE LAY LENGTH 42" INTO FIRE RISER ROOMSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 121 LF OF 4" PVC SANITARY SEWER SERVICE AT 12 " PER FOOT SLOPEINV IN TO BUILDING: 4781.15'SEE PLUMBING PLANS FOR CONTINUATION INTO BUILDING123INSTALL ± 44 LF OF 2" COPPER, TYPE K, FIRE SERVICE AT 6.5' MINIMUM DEPTH BURY DEPTHSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 50 LF OF 2" COPPER, TYPE K, ANNEALED DOMESTIC WATER SERVICE AT 6.5'MINIMUM BURY DEPTH. PIPE LAY LENGTH 42" INTO FIRE RISER ROOMSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 181 LF OF 4" PVC SANITARY SEWER SERVICE AT 12 " PER FOOT SLOPEINV IN TO BUILDING: 4782.63'SEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 43 LF OF 2" COPPER, TYPE K, FIRE SERVICE AT 6.5' MINIMUM DEPTH BURY DEPTHSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 46 LF OF 2" COPPER, TYPE K, ANNEALED DOMESTIC WATER SERVICE AT 6.5'MINIMUM BURY DEPTH. PIPE LAY LENGTH 42" INTO FIRE RISER ROOMSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 57 LF OF 4" PVC SANITARY SEWER SERVICE AT 12 " PER FOOT SLOPEINV IN TO BUILDING: 4781.00'SEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ±43 LF OF 2" COPPER, TYPE K, FIRE SERVICE AT 6.5' MINIMUM DEPTH BURY DEPTHSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 46 LF OF 2" COPPER, TYPE K, ANNEALED DOMESTIC WATER SERVICE AT 6.5'MINIMUM BURY DEPTH. PIPE LAY LENGTH 42" INTO FIRE RISER ROOMSEE PLUMBING PLANS FOR CONTINUATION INTO BUILDINGINSTALL ± 50 LF OF 4" PVC SANITARY SEWER SERVICE AT 12 " PER FOOT SLOPEINV IN TO BUILDING: 4782.25'SEE PLUMBING PLANS FOR CONTINUATION INTO BUILDING45678910111212548710113126CONNECT TO EXISTING 8"WATER STUBPROPOSED TRANSFORMERLOCATIONPROPOSEDTRANSFORMER LOCATIONPROPOSED TRANSFORMERLOCATION9FIRE RISERROOMFIRE RISERROOMFIRE RISERROOMFIRE RISERROOMPROPOSED IRRIGATIONCONDUIT (TYP.)MATCH LINE SHEET C3.1PROPOSED EV CHARGING STATIONSSEE SHEET E1.0 FOR DETAILSUNDERGROUNDSTORMWATERSYSTEM DETAILSON GRADINGSHEETSEXISTING STORM15" STORM MAINUNDERGROUNDSTORMWATERSYSTEM DETAILSON GRADINGSHEETSUNDERGROUNDSTORMWATERSYSTEM DETAILSON GRADINGSHEETS