Loading...
HomeMy WebLinkAbout001_SA000 COVER SHEETPROJECT LOCATION 1/2 M ILE PROJECT LOCATION 1/2 M ILE PROJECT LOCATION 1/2 M ILE Project Number: Drawn By: Reviewed By: Approved By: Issue Date Gallatin County Commission 311 West Main Street Bozeman, MT, 59715 Telephone: 406-582-2300 ThinkOne Architects 101 E Main St. Studio 1 Bozeman, MT, 59715 T: 406-586-7020 Architect AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, CO 80211 T: 303-294-9448 Associate Architect Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Civil Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Structural Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Mechanical Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Plumbing Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Electrical Engineer Desgin 5 Landscape Architecture 111 North Tracy Avenue Bozeman, MT 59715 T: 406-587-4873 Landscape Architect Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Fire Protection Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Technology Engineer AMD JT T1 5/5/2022 11:46:41 AMSA-000 COVER SHEET 21-311 GALLATIN COUNTY COURTS 06 MAY 2022SITE PLAN SUBMITTAL 615 SOUTH 16TH AVENUE, BOZEMAN, MONTANA, 59715 21-311 GALLATIN COUNTY CITY OF BOZEMAN UNIFIED DEVELOPEMENT CODE (UDC) PARCEL & SITE COVERAGE INFORMATION: PROPERTY ADDRESS: 615 SOUTH 16TH AVENUE, BOZEMAN, MONTANA 59715 LEGAL DESCRIPTION: TRACT A S12,T02 S, R05 E, LAW JUSTICE CENTER (15.772 ACRES : PLI) TRACT B S12, T02 S, R05 E, COS 691, PARCEL B (3.00 ACRES : R-0 ZONING) PARCEL 2 S12, T02 S, R05 E, TR IN SW4SW4 60'X131.73' (0.172 ACRES : R-0 ZONING) TOTAL:18.9 ACRES (825,200 SF) PROPOSED SITE AREA: 18.9 ACRES (825,200 SF) ZONING: PLI (PUBLIC LANDS & INSTITUTIONAL) PERMITTED USE: ESSENTIAL SERVICES (TYPE III) DEVELOPMENT AREA: 8.2 ACRES (357,292 SF) BLOCK FRONTAGE: OTHER PARKLAND REQUIREMENT: NOT REQUIRED OPEN SPACE: NOT REQUIRED -PLI CLASSIFIED AS INDUSTRIAL WETLANDS/FLOODPLAIN/WATER FEATURE: NOT APPLICABLE FORM & INTENSITY STANDARDS: SITE-WIDE FLOOR AREA SUMMARY:SQUARE FOOTAGE EXISTING STRUCTURES TO REMAIN:91,671 SF EXISTING DETENTION CENTER (73,266 SF) EXISTING RE-ENTRY FACILITY (6,368 SF) EXISTING STORAGE FACILITY (12,037 SF) EXISTING STRUCTURES TO BE REMOVED:63,709 SF EXISTING LAW & JUSTICE BLDG 61,075 SF LOWER LEVEL (20,699 SF) ENTRY LEVEL (20,080 SF UPPER LEVEL (20,296 SF) EXISTING COURT #3 BUILDING 2,634 SF NEW COURTS BUILDING 69,128 SF MAIN LEVEL 60,817 SF MEZZANINE 8,311 SF NET ADDITION OF BUILDING AREA ON SITE: 5,419 SF ADDED FLOOR AREA RATIO (FAR) -PROPOSED:FLOOR AREA = 69,130 SF SITE AREA = 357,292 SF FAR = 0.19:1 LOT COVERAGE: SQUARE FOOTAGE % OF SITE EXIST BUILDINGS 91,671 SF 11% DETENTION CENER (73,266 SF) RE-ENTRY FACILITY (6,368 SF) STORAGE FACILITY (12,037 SF) PROPOSED BUILDINGS 60,817 SF 7.4% DRIVEWAY, CIRCULATION, PARKING 292,200 SF 35% LANDSCAPE 380,512 SF 46.6% PUBLIC ROW 0 SF 0% TOTAL SITE 825,200 SF 100% LOT AND FLOOR AREA STANDARDS: NO REQUIREMENT BUILDING HEIGHT STANDARDS: NO REQUIREMENT MINUMUIM SETBACKS: NO REQUIREMENT -ADJACENT DISTRICTS ARE R-0 & R-3 PARKING TABLE/CALCULATION: ACTUAL PROPOSED FLOOR AREA: 69,130 SF REDUCTIONS PER 38.540.010.1 (NOT ASSUMED) TOTAL:= 69,130 SF TOTAL REDUCTIONS = (STANDARD 85% REDUCTION) MINIMUM PARKING = 69,130 SF x 85% / 250 = 235 SPACES MAXIMUM PARKING = (222 X 1.25 SPACES)= 294 SPACES PROPOSED PARKING = 206 SPACES (ADDITIONAL PARKING PROVIDED IN EXISTING SOUTHERN LOT) (SEE BELOW FOR SITE-WIDE PARKING ANALYSIS) BICYLE PARKING MIN REQUIRED= 10% OF REQUIRED PARKING STALLS OR 24 PROPOSED = 22 BIKE PARKING STALLS REQUIRED PARKING (SITE-WIDE CALCULATION): (E) DETENTION CENTER:86 SPACES (E) RE-ENTRY FACILITY:22 SPACES (E) STORAGE FACILITY:12 SPACES PROP. COURTS FACILITY:235 SPACES TOTAL MIN PARKING:352 SPACES MAX PARKING (125% of MIN):440 SPACES MIN 2% ACCESSIBLE:8 SPACES SITE-WIDE CALCULATION: EXISTING PARKING -REMOVED LAW & JUSTICE LOT WEST / SOUTH (118 SPACES) EXISTING PARKING TO REMAIN (E) DETENTION CENTER:63 SPACES (E) RE-ENTRY BUILDING:6 SPACES (E) STORAGE FACILITY:9 SPACES (E) OVERFLOW LOT:180 SPACES PROPOSED PARKING (N) DETENTION CENTER:15 SPACES (N) PROP. COURTS FACILITY:190 SPACES EXISTING SITE TOTAL:376 SPACES PROPOSED SITE TOTAL:463 SPACES NET ADDITIONAL PARKING ON SITE:87 SPACES SIGN CALCULATION: MAX SQ FT AREA: 250 (PLI) BUILDING FRONTAGE:PROPOSED BUILDING SIGN: ACTUAL = 360'-0"COUNTY SEAL = 49 SF FIRST 25' = 2 SF WALL MOUNTED BUILDING NAME = 40 SF > 25' = 335' X 1.5 = 502.5 SF TOTAL ALLOWABLE = 2 + 502.5 = 504.5 SF TOTAL PROPOSED = 89 SF BUILDING ADDRESS SIGN TO BE PROVIDED CIVIL NO DRAWING SHEET GENERAL NO DRAWING SHEET DRAWING INDEX LOCATION/VICINITY MAP ZONING MAP COMMUNITY PLAN FUTURE LAND USE MAP GALLATIN COUNTY COURTS BUILDING ENTRY PERSPECTIVE SOUTHWEST ENTRY PERSPECTIVE NOTE: PERPESCTIVE RENDERINGS ARE CONCEPTUAL TO ILLUSTRATE MASSING/FORM AND GENERAL DESIGN INTENT. REFER TO ENCLOSED DRAWINGS FOR PROPOSED SITE DESIGN, LANDSCAPING AND BUILDING FINISHES. ALL WORK INCLUDED IN THIS CONTRACT, SHALL COMPLY WITH THE LATEST EDITION OF INTERNATIONAL BUILDING CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, ICC ELECTRICAL CODE, AND ALL OTHER LAWS, CODES, OF LOCAL, COUNTY, STATE, AND LOCAL JURISDICTION INVOLVED. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO STARTING THE WORK. THE CONTRACTOR SHALL VERIFY GRADES, SITE CONDITIONS, AND COMPARE THAT WITH THE DIMENSIONS SHOWN ON THE DRAWINGS. WHERE CONFLICT EXISTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT UPON RECOGNITION OF ANY DISCREPANCY. THE CONTRACTOR SHALL CAREFULLY STUDY ALL PLANS AND DRAWINGS, AND SHALL REPORT IMMEDIATELY TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS THEY MAY DISCOVER. THE CONTRACTOR SHALL NOT WORK WITHOUT DRAWINGS. THE CONTRACTOR SHALL CONSULT THE ARCHITECT OR SUBMIT SHOP DRAWINGS AND/OR LITERATURE TO THE ARCHITECT FOR APPROVAL PRIOR TO STARTING THE WORK. THE GENERAL CONTRACTOR SHALL GIVE ALL NOTICES AND SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND ORDERS OF PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. IF THE CONTRACTOR OBSERVES THAT ANY OF THE CONTRACT DOCUMENTS ARE AT VARIANCE THEREWITH IN ANY RESPECT THEY SHALL PROMPTLY NOTIFY THE ARCHITECT OF ANY CHANGES REQUIRING ADJUSTMENT WITH APPROPRIATE MODIFICATION. ONLY APPROVED 'CONSTRUCTION SET' MARKED DRAWINGS INCORPORATING ALL ADDENDUM AND DIMENSION CLARIFICATIONS SHALL BE USED DURING THE EXECUTION OF THE WORK. THE CONTRACTOR SHALL USE WRITTEN DIMENSIONS ONLY, OR AS DIRECTED BY ARCHITECT. THE CONTRACTOR SHALL NOT SCALE DRAWINGS. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT LIMIT APPLICATION OF ANY DRAWING OR DETAIL. THEY MAY APPLY TO OTHER, SAME, OR SIMILAR CONDITIONS NOT REFERENCED. INTERIOR WALL DIMENSIONS (FOR NEW WALLS ONLY) ARE TO FACE OF STUD FRAMING UNLESS OTHERWISE NOTED. SECTION AND INTERIOR ELEVATION DIMENSIONS ARE TO THE TOP OF CONCRETE OR METAL DECKING UNLESS OTHERWISE NOTED. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION OF SUBCONTRACTORS WORK TO SECURE COMPLIANCE OF DRAWINGS AND SPECIFICATIONS, THE ACCURATE LOCATION OF STRUCTURE MEMBERS, AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, ELEVATORS, AND MISCELLANEOUS EQUIPMENT. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL AND ELECTRICAL EQUIPMENT WITH RESPECTIVE SUB-CONTRACTORS, AS WELL AS SHOP DRAWINGS REVIEWED BY THE ARCHITECT. CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT AND PROVIDE ALL BUCK-OUT BLOCKING AND BACKING REQUIRED BY THIS CONTRACT AND OTHERS. WHERE PIPING, CONDUIT, AND/OR DUCTS PASS THROUGH FIRE RATED WALLS, PACK AROUND OPENINGS WITH SAVING OR SPRAY INSULATION. PROVIDE FIRE DAMPERS WHERE NECESSARY. THE PROPOSED BUILDING AND SITE PLAN MAKE ALL NECESSARY ACCOMMODATIONS TO MEET ALL LOCAL AND STATE ACCESSIBILITY REQUIREMENTS. GENERAL NOTES SA-000 COVER SHEET ARCHITECTURAL NO DRAWING SHEET LANDSCAPE NO DRAWING SHEET SA-101 FLOOR PLAN -LEVEL 1 -OVERALL SA-102 FLOOR PLAN -MEZZANINE -OVERALL SA-103 FLOOR PLAN -ROOF LEVEL -OVERALL SA-200 EXTERIOR ELEVATIONS SA-201 EXTERIOR ELEVATIONS SA-202 EXTERIOR PERSPECTIVES SA-203 EXTERIOR MATERIALS PALETTE L-000 LANDSCAPE SITE PLAN L-001 LANDSCAPE NOTES AND SCHEDULES L-300 LANDSCAPE PLAN L-301 LANDSCAPE PLAN L-302 LANDSCAPE PLAN L-303 LANDSCAPE PLAN L-500 LANDSCAPE DETAILS L-501 LANDSCAPE DETAILS L-600 IRRIGATION PLAN L-601 IRRIGATION PLAN ELECTRICAL NO DRAWING SHEET ES-100 SITE PHOTOMETRIC PLAN ES-101 LIGHTING CUTSHEETS ES-102 LIGHTING CUTSHEETS ES-103 LIGHTING CUTSHEETS ES-104 LIGHTING CUTSHEETS SA-001 SITE PLAN SA-002 SITE PLAN -ENLARGED -NORTH SA-003 SITE PLAN -ENLARGED -SOUTH SA-004 SITE DETAILS SA-005 ENCLOSURE DETAILS SA-006 SITE WALLS & RAILINGS SA-007 CONSTRUCTION ROUTE MAP AND MANAGEMENT PLAN C-001 C-100 C-101 C-102 C-103 SITE TOPO AND UTILITIES PLAN CIVIL SITE PLAN SITE UTILITY PLAN - NORTH SITE UTILITY PLAN - SOUTH OVERALL SITE GRADING PLAN