Loading...
HomeMy WebLinkAbout37_IR-1 IRRIGATION PLAN1"1"112"112"C2"2"2"2"2"2"2"2"2"2"2"2"1"1"2"2"112"112"112"14.21"222.31"325.21"411.21"510.91"112"IRRIGATION NOTES1.IRRIGATION SYSTEM DESIGN BASED ON 35 GPM AT 70 PSI.2.IRRIGATION DESIGN IS FROM THE POINT OF CONNECTION (POC) ONLY. THE DESIGN IS BASED ON GALLONSPER MINUTE (GPM) AND POUNDS PER SQUARE INCH (PSI) FURNISHED BY OTHERS.3.IRRIGATION CONTRACTOR IS TO VERIFY POINT OF CONNECTION IN THE FIELD. INSTALLER IS TO CONFIRMTHE MINIMUM DISCHARGE REQUIREMENTS OF THE POINT OF CONNECTION AS INDICATED ON THE LEGENDPRIOR TO INSTALLATION.4.THE PRESSURE REQUIREMENT AT THE POINT OF CONNECTION IS BASED ON NO MORE THAN 5-FEET OFELEVATION CHANGE IN THE AREAS OF IRRIGATION.5.ALL PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONSAND ACCORDING TO LOCAL BUILDING, ELECTRICAL AND PLUMBING CODES.6.IRRIGATION CONTRACTOR WILL ARRANGE INSPECTIONS REQUIRED BY LOCAL AGENCIES AND ORDINANCESDURING THE COURSE OF CONSTRUCTION AS REQUIRED. ALL WIRING TO BE PER LOCAL CODE. BACKFLOWPREVENTION PER LOCAL CODE.7.LOCATION OF IRRIGATION COMPONENTS SHOWN ON DRAWINGS IS APPROXIMATE. ACTUAL PLACEMENT MAYVARY SLIGHTLY AS REQUIRED TO ACHIEVE FULL, EVEN COVERAGE.8.ALL SPRINKLER HEADS SHALL BE INSTALLED PERPENDICULAR TO FINISH GRADES, EXCEPT AS OTHERWISEINDICATED.9.INSTALL IRRIGATION MAINS WITH A MINIMUM 36" OF COVER BASED ON FINISH GRADES. INSTALL IRRIGATIONLATERALS WITH A MINIMUM 12" OF COVER BASED ON FINISH GRADES.10.PIPE LOCATIONS ARE DIAGRAMMATIC. VALVES AND MAINLINE SHOWN IN PAVED AREAS ARE FOR GRAPHICCLARITY ONLY.11.THE IRRIGATION CONTRACTOR SHALL COMPLY WITH PIPE SIZES AS INDICATED.12.THE FOLLOWING SHOULD BE NOTED REGARDING TO PIPE SIZING: IF A SECTION OF UN-SIZED LATERAL PIPEIS LOCATED BETWEEN TWO IDENTICALLY SIZED SECTIONS THE UN-SIZED SECTION SHALL BE OF THE SAMESIZE. IF A SECTION OF UN-SIZED LATERAL PIPE IS NOT SIZED AT THE END OF A ZONE AND IS NOT BETWEENTWO IDENTICALLY SIZED SECTIONS THE UN-SIZED SECTION(S) SHALL BE 1-INCH.13.ALL WIRE SPLICES OR CONNECTIONS SHALL BE MADE WITH APPROVED WATERPROOF WIRE CONNECTORSAND BE IN A VALVE OR SPLICE BOX.14.ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE HUNTER ID-1 DECODER WIRE, ULAPPROVED DIRECT BURY.15.THE DESIGN IS BASED ON THE SITE INFORMATION AND/OR DRAWING SUPPLIED WITH THE DESIGN CRITERIABEING SET(AREA TO BE IRRIGATED, EQUIPMENT MANUFACTURER AND MODEL TO BE USED, WATER SOURCEINFORMATION, ELECTRICAL POWER AVAILABILITY, ETC...). SITEONE LANDSCAPE SUPPLY BEARS NORESPONSIBILITY OR LIABILITY FOR ANY ERRORS IN DESIGN OR INSTALLATION THAT ARISE DUE TOINACCURACIES IN THE ABOVE REFERENCED INFORMATION SUPPLIED TO SITEONE LANDSCAPE SUPPLY INRELATION TO THIS PROJECT, UNLESS OTHERWISE NOTED.SYMBOLMANUFACTURER/MODELQTYHUNTER PROS-06 8` RADIUS27HUNTER PROS-06 10` RADIUS12HUNTER PROS-06 12` RADIUS4HUNTER PROS-06 ADJ3HUNTER MP STRIP PROS-06-PRS40-CV6HUNTER MP1000 PROS-06-PRS40-CV3HUNTER MP2000 PROS-06-PRS40-CV21HUNTER MP3000 PROS-06-PRS40-CV9SYMBOLMANUFACTURER/MODELQTYHUNTER PGP-06 1.58SYMBOLMANUFACTURER/MODELQTYHUNTER PCZ-101-40 1"1HUNTER HDL-09-12-CV DRIP RING14SYMBOLMANUFACTURER/MODELQTYHUNTER PGV-101G 1"4HUNTER I-CORE CONTROLLER1POINT OF CONNECTION1IRRIGATION LATERAL LINE: PVC SCHEDULE 4028.1 L.F.IRRIGATION LATERAL LINE: PVC SCHEDULE 40 1"2,299 L.F.IRRIGATION LATERAL LINE: PVC SCHEDULE 40 1 1/2"98.8 L.F.IRRIGATION MAINLINE: PVC CLASS 160 SDR 26 1 1/2"124.4 L.F.PIPE SLEEVE: PVC CLASS 160 SDR 26 2"81.4 L.F.C#"#IRRIGATION SCHEDULEGenerated:2022-09-09 11:03P.O.C. NUMBER: 01Water Source Information:FLOW AVAILABLECustom Max Flow:35 GPMFlow Available35 GPMPRESSURE AVAILABLEStatic Pressure at POC:70 PSIPressure Available:70 PSIDESIGN ANALYSISMaximum Station Flow:24.59 GPMFlow Available at POC:35 GPMResidual Flow Available:10.41 GPMPressure Req. at Critical Station:46.54 PSILoss for Fittings:0.06 PSILoss for Main Line:0.62 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:11.15 PSICritical Station Pressure at POC:58.37 PSIPressure Available:70 PSIResidual Pressure Available:11.63 PSICRITICAL ANALYSISNUMBERMODELSIZETYPEGPMWIREPSIPSI @ POCPRECIP1HUNTER PCZ-101-401"DRIP EMITTER4.221.035.635.60.57 in/h2HUNTER PGV-101G1"TURF ROTARY22.333.638.839.10.36 in/h3HUNTER PGV-101G1"TURF ROTARY25.2490.546.948.00.55 in/h4HUNTER PGV-101G1"TURF ROTOR11.2112.039.639.90.33 in/h5HUNTER PGV-101G1"TURF SPRAY10.88127.537.437.70.47 in/hCommon Wire124.4VALVE SCHEDULENUMBERMODELTYPEPRECIPIN./WEEKMIN./WEEKGAL./WEEKGAL./DAY1HUNTER PCZ-101-40DRIP EMITTER0.57 in/h1.51576592202HUNTER PGV-101GTURF ROTARY0.36 in/h1.52505,5761,8593HUNTER PGV-101GTURF ROTARY0.55 in/h1.51654,1641,3884HUNTER PGV-101GTURF ROTOR0.33 in/h1.52733,0581,0195HUNTER PGV-101GTURF SPRAY0.47 in/h1.51932,101700TOTALS:1,03815,5575,186WATERING SCHEDULE 3 DAYS PER WEEK Project Name:Outlaw Urban FarmsBurnsville, MN. 55337 Design Date: Drawn By:REVISIONSDescriptionDrawing Title:Irrigation Plan Customer Name:Drawing Scale:PS Project Number:1" = 20'300395Sheet Number:IR-109/09/2022Tom BjornbergDate 1 2 3 4 5 60' 10' 20' 40'SCALE: 1" = 20' - 0" 5102 N Garfield Ave Loveland, CO 80538 Phone 970.667.6605 Fax 970.667.3525http://projectservices.siteone.com 800.347.4272Project Services TM 12/12/202212/13/202212/14/2022