HomeMy WebLinkAbout064_A-E2.1 BUILDING 7 - ELECTRICAL - 2ND FLOORWDREF.DWDWREF.33333333GFIGFIGFIGFIGFIGFIGFIGFIGFI3GFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFI333333333WD3344GENERAL NOTES1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT.2. GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL, ELECTRICAL, AND PLUMBING.APPLICABLE CODES:2018 INTERNATIONAL RESIDENTIAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODEDESIGN CRITERIASEISMIC ZONE D0115 MPH WINDA. ALL OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY ROOMS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTERINSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.B. IN EVERY KITCHEN, FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, SUN ROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THESE PROVISIONS:1. RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET, FROM A RECEPTACLE OUTLET.2. A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL COUNTERTOP SPACE 12 INCHES OR WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 INCHES, MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. 3. AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND COUNTERTOP SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES OR GREATER.4. AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH PENINSULAR COUNTERTOP SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES OR GREATER. A PENINSULAR COUNTERTOP IS MEASURED FROM THE CONNECTING EDGE.5. AT LEAST ONE RECEPTACLE OUTLET THAT IS ACCESSIBLE WHILE STANDING AT GRADE LEVEL AND LOCATED NOT MORE THAN 6 FEET, 6 INCHES ABOVE GRADE, SHALL BE INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH DWELLING UNIT HAVING DIRECT ACCESS TO GRADE. BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FEET, 6 INCHES ABOVE THE BALCONY, DECK, OR PORCH SURFACE. 6. AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED TO SERVE LAUNDRY APPLIANCES. 7. AT LEAST ONE RECEPTACLE OUTLET, IN ADDITION TO ANY PROVIDED FOR SPECIFIC EQUIPMENT, SHALL BE INSTALLED IN EACH BASEMENT AND IN EACH ATTACHED GARAGE, AND IN EACH DETACHED GARAGE OR ACCESSORY BUILDING THAT IS PROVIDED WITH ELECTRICAL POWER. WHERE A PORTION OF THE BASEMENT IS FINISHED INTO ONE OR MORE HABITABLE ROOM(S), EACH SEPARATE UNFINISHED PORTION SHALL HAVE A RECEPTACLE OUTLET INSTALLED IN ACCORDANCE WITH THIS SECTION. 8. HALLWAYS OF 10 FEET OR MORE IN LENGTH SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET. THE HALL LENGTH SHALL BE CONSIDERED THE LENGTH MEASURED ALONG THE CENTERLINE OF THE HALL WITHOUT PASSING THROUGH A DOORWAY. 9. FOYERS THAT ARE NOT PART OF A HALLWAY AND THAT HAVE AN AREA THAT IS GREATER THAN 60 FT2 SHALL HAVE A RECEPTACLE(S) LOCATED IN EACH WALL SPACE THAT IS 3 FEET OR MORE IN WIDTH AND UNBROKEN BY DOORWAYS, FLOOR-TO-CEILING WINDOWS, AND SIMILAR OPENINGS. 10. ALL RECEPTACLES WITHIN A DWELLING SHALL BE TAMPER RESISTANT.11. BATHROOM CIRCUITING SHALL BE EITHER: A) A 20 AMPERE CIRCUIT DEDICATED TO EACH BATHROOM, OR B) AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS, PER PER NEC ARTICLE 210.11(C)3ELECTRICAL NOTESELECTRICAL LEGENDRECESSED CAN LIGHTSURFACE MOUNTED LIGHTWALL MOUNTED LIGHTPENDANT LIGHTEXHAUST FAN or FAN/LIGHT COMBINATIONCEILING FANSDSMOKE DETECTORWALL SWITCHDUPLEX OUTLETCEILING FAN/ LIGHT COMBINATIONWALL SWITCH 3-WAY3WALL SWITCH 4-WAY4DUPLEX OUTLET - GROUND FAULT INTERRUPTERGFIDUPLEX OUTLET - WEATHERPROOFWPFLUORESCENT LIGHTWALL SWITCH w/ DIMMERDCO CARBON MONOXIDE DETECTOR1. VERIFY ALL LIGHT FIXTURE TYPES & LOCATIONS WITH OWNER2. VERIFY ALL SWITCH TYPE AND LOCATIONS WITH OWNER3. VERIFY ALL OUTLET LOCATIONS WITH OWNER4. PROVIDE CABLE & DATA OUTLETS PER OWNER5. PROVIDE SPEAKER SYSTEM PER OWNERNOTE1. SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A DOORWAY OF A BATH ROOM THAT CONTAINS A SHOWER OR TUB PER SECTION R314.3.2. SMOKE ALARMS SHALL BE NOT LESS THAN 36" HORIZONTALLY FROM A SUPPLY REGISTER AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW OF THOSE REGISTERS.3. SMOKE ALARMS SHALL BE NOT LESS THAN 36" HORIZONTALLY FROM TIP OF FAN BLADE OF SUSPENDED CEILING FAN.4. IONIZATION SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 20' MEASURED HORIZONTALLY FROM PERMANENTLY INSTALLED COOKING APPLIANCE PER SECTION R3143.1.5. IONIZATION SMOKE ALARMS WITH ALARM-SILENCING SHALL NOT BE INSTALLED WITHIN 10' MEASURED HORIZONTALLY FROM PERMANENTLY INSTALLED COOKING APPLIANCE PER SECTION R314.1.6. PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 6' MEASURED HORIZONTALLY FROM PERMANENTLY INSTALLED COOKING APPLIANCE PER SECTION R3143.1.7. WHERE MORE THAN ONE CARBON MONOXIDE AND/OR SMOKE ALARMS ARE REQUIRED THEY SHALL BE INTERCONNECTED IN A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE DWELLING PER SECTION R314.4. & R315.58. CARBON MONOXIDE AND SMOKE ALARMS SHALL RECEIVE POWER FROM THE PRIMARY WIRING OF DWELLING, AND SHALL REQUIRE BATTERY BACKUP POWER WHEN THE PRIMARY POWER IS INTERRUPTED PER SECTION R314.6 & R315.69. CARBON MONOXIDE ALARMS SHALL BE OUTSIDE THE IMMEDIATE VICINITY OF BEDROOMS WHEN REQUIRED PER SECTION R315.2.1 PER SECTION R315.3.NOTEGFIGFIDNGDUPSDSDCOSDSD220V220VGFIDNUPSDSDCOSDSD220V220VGFIGD(2) FLOOR OUTLETS, LOCATION T.B.D.(2) FLOOR OUTLETS, LOCATION T.B.D.PROVIDE UNDER CABINET LIGHTING IN KITCHENPROVIDE UNDER CABINET LIGHTING IN KITCHEN(406) 552-4490www.blackmountainarch.comBLACK MOUNTAIN ARCHITECTURE 2020E2.1ELECTRICALPLAN - 2NDFLOORSWISS PLAZA DUPLEXBUILDING 7 (3006 N. 27th AVE.)3006 N. 27th AVENUE, BOZEMAN, MONTANAPERMIT SETNOVEMBER 15, 2022200241/4" = 1'-0"1ELECTRICAL - 2ND FLOOR