HomeMy WebLinkAbout052_A2.3 BUILDING 7 - TERRACE FLOOR PLANDNDN1615141312111098765432116151413121110987654321OPEN TO BELOW45' - 0"45' - 0"90' - 0"ROOF TERRACE44-0 X 16-8ROOF TERRACE44-0 X 16-826' - 10"17' - 2"BALCONY43-10 X 6-042" HIGH WALLHOSE BIB42" HIGH GUARDRAILHOSE BIB42" HIGH GUARDRAIL42" HIGH GUARDRAIL42" HIGH GUARDRAILBALCONY43-10 X 6-0OPEN TO BELOW19' - 10"3' - 11"3' - 1"72" X 30"SLIDER(6' -8") HEAD72" X 30"SLIDER(6' -8") HEAD72" X 30"SLIDER(6' -8") HEAD36" x 80"FULL LITETEMPERED36" x 80"FULL LITETEMPERED72" X 30"SLIDER(6' -8") HEAD72" X 30"SLIDER(6' -8") HEAD72" X 30"SLIDER(6' -8") HEAD7' - 11"14' - 10"12' - 3"6' - 6"3' - 6"3' - 6"6' - 6"12' - 3"14' - 10"7' - 11"17' - 2"26' - 10"19' - 10"3' - 11"3' - 1"44' - 0"44' - 0"90' - 0"3' - 0"3' - 0"11' - 3"36" x 80"45' - 0"45' - 0"41' - 6"3' - 6" 3' - 6"41' - 6"30" X 30"FIXED(6' -8") HEAD30" X 30"FIXED(6' -8") HEAD42" GUARDRAIL42" GUARDRAIL1-HR FIRE PARTITION -TYPICAL BETWEEN DWELLING UNITS16R @ 7 1/8", 7T @ 10"16R @ 7 1/8", 7T @ 10"36" HIGH MIN. GUARDRAIL36" HIGH MIN. GUARDRAILGAS FOR BBQ. LOCATION T.B.D.GAS FOR BBQ. LOCATION T.B.D.HANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. 34"-38" IN HEIGHT WITH A GRIPPING SURFACE PER R311.7.8.3.HANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. 34"-38" IN HEIGHT WITH A GRIPPING SURFACE PER R311.7.8.3.FLOOR AREASPER UNIT1ST FLOOR (COMMERCIAL): 1,980 SF GROSS2ND FLOOR (RESIDENTIAL): 1,908 SF GROSSTOTAL: 3,888 SF GROSSRESIDENTIAL AREA = 49.1% GROSS AREA OF BLDG.BALCONY: 338 SFROOF TERRACE: 740 SFGENERAL NOTES1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT.2. GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL, ELECTRICAL, AND PLUMBING.APPLICABLE CODES:2018 INTERNATIONAL RESIDENTIAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODEDESIGN CRITERIASEISMIC ZONE D0115 MPH WINDPLAN NOTES1. CONTRACTOR TO CONFIRM SIZE & TYPE OF WATER HEATER, SET HEATER IN 1 1/2" DEEP 24 GA. GALVANIZED STEEL PAN DRAINED w/ 3/4" INDIRECT WASTE PIPE. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO PREVENT HORIZONTAL MOVEMENT2. ELEVATE WATER HEATER 18" MINIMUM ABOVE GARAGE SLAB TO ANY ELEMENT OR SWITCH THAT MAY SPARK3. A PERMANENT CRAWL SPACE LADDER OR ATTIC SPACE PULL DOWN LADDER IS TO BE INSTALLED TO ACCESS THE HEATING UNIT OR BOILER. 4. THE MAXIMUM CLEAR TRAVEL PATH FROM THE CRAWL SPACE OR ATTIC ACCESS OPENING TO THE HEATING UNIT OR BOILER IS 20 FEET.5. PROVIDE LIGHT FIXTURE CONTROLLED BY A SWITCH LOCATED AT THE CRAWL SPACE ACCESS HATCH & A RECEPTACLE OUTLET SHALL BE INSTALLED AT OR NEAR THE FURNACE.MECHANICALEGRESS WINDOWS (EERO)SAFETY GLAZING REQUIREMENTS1. TEMPER GLAZING AT LOCATIONS SPECIFED IN IRC 2018 R308.4 FIRE RESISTANT CONSTRUCTION REQUIREMENTS1. DOOR(S) BETWEEN GARAGE & HOUSE SHALL BE 20-MINUTE & EQUIPPED WITH A SELF-CLOSING DEVICE.2. INSTALL 1/2" GWB @ WALLS & UNDER-STAIR SURFACE IN ENCLOSED ACCESSIBLE SPACE UNDER STAIRS 3. 1/2" GWB SHALL BE INSTALLED ON ALL WALLS SEPARATING THE GARAGE FROM THE DWELLING .4. WHERE HABITABLE ROOMS ARE ABOVE A GARAGE, APPLY 5/8" TYPE 'X' GWB ON GARAGE CEILING & 1/2" GWB ON WALLS SUPPORTING FLOOR ABOVE5. FOAM INSULATION SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVEDTHERMAL BARRIER OF MINIMUM 1/2 INCH GWB OR A MATERIAL THAT IS TESTED IN ACCORDANCE NFPA 275.6. PROVIDE FIRE BLOCKING VERTICALLY AT THE CEILING AND FLOOR LEVELS & HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.7. PROTECTION OF PENETRATIONS IN WALLS OR FLOOR/CEILING ASSEMBLIES ARE REQUIRED TO BE FIRE RESISTANCE RATED IN ACCORDANCE WITH SECTION R302.2 OR R302.38. THE FLAME SPREAD FOR WALLS AND CEILINGSFINISHED TO BE NOT GREATER THAN 200. (R302.9.1)9. THE SMOKE-DEVELOPED INDEX FOR WALLS AND CEILINGS SHALL NOT HAVE AN INDEX GREATER THAN 450. (R302.9.2)ALL SLEEPING ROOMS SHALL HAVE ANEMERGENCY ESCAPE AND RESCUE OPENING (EERO), DIRECTLY TO THE OUTSIDE VIA A DOOR OR WINDOW. EGRESS WINDOWS SHALL MEET THE REQUIREMENTS OF IRC 2018 SECTION R310.1ENERGY REQUIREMENTS2018 INTERNATIONAL ENERGY CONSERVATION CODEMONTANA CLIMATE ZONE 6BINSULATION & FENESTRATION REQUIRMENTS BY COMPONENTCEILING FLAT: FLAT R-49VAULTED R-38WALLS: ABOVE GRADE R-21BASEMENTS R-19 CAVITY/ R-15 CONT.CRAWL SPACE R-19 CAVITY/ R-15 CONT.FLOORS: OVER UNHEATED SPACES R-30PERIMETER SLAB FOR 4 FT. R-10EXTERIOR DOORS R-3WINDOWS NFRC UNIT RATING U-0.30WATER HEATER ENERGY FACTOR RATING 0.58HEATING SYSTEM ENERGY EFFICIENCY RATING 78%(AFUE FOR GAS; HSPF HEAT PUMP)1-HR COMMON WALL1-HR COMMON WALL ASSEMBLY B/W DWELLING UNITSDESIGN NO. U341 (ANSI/UL 263), STC 51 (TEST NO: NGC 2191)• 5/8" SHEETROCK FIRECODE C CORE GYPSUM PANELS APPLIED VERTICALLY OR HORIZONTALLY TO EA. SIDE OF DOUBLE ROW OF 2X6 WOOD STUDS w/ 1-7/8" LONG 6d COATED NAILS, 7" O.C. - JOINTS STAGGERED ON OPPOSITE SIDES• (2) 2X6 WOOD STUD WALLS ON SEPARATE 2X6 PLATES (NO MIN. SPACING), 2X6 STUDS SPACED AT 16" O.C.• 7/16" WOOD STRUCTURAL PANELS MAY BE INSTALLED ON THE INSIDES OF EACH STUD WALL IF REQUIRED STRUCTURALLY• 3 1/2" (MIN.) BATT INSULATION INSTALLED IN 1 STUD WALL TO ACHIEVE STC RATING (51)(406) 552-4490www.blackmountainarch.comBLACK MOUNTAIN ARCHITECTURE 2020A2.3TERRACE FLOORPLANSWISS PLAZA DUPLEXBUILDING 7 (3006 N. 27th AVE.)3006 N. 27th AVENUE, BOZEMAN, MONTANAPERMIT SETNOVEMBER 15, 2022200241/4" = 1'-0"1TERRACE LEVEL