Loading...
HomeMy WebLinkAbout051_A2.2 BUILDING 7 - 2ND FLOOR PLANWDREF.DWUPDWUPREF.2423222120191817161514131211102423222120191817161514131211101615141312111098765432116151413121110987654321WD45' - 0"45' - 0"90' - 0"44' - 0"BATH6-0 X 10-0LAUND.6-10 X 6-0PWDR5-0 X 6-0BEDROOM 311-0 X 13-0BEDROOM 211-0 X 12-9MASTER BED12-0 X 16-8W.I.C.6-5 X 12-9MASTERBATH15-6 X 6-0KITCHEN15-0 X 12-0LIVING14-6 X 15-6DINING10-0 X 15-53-0 X 6-0 SHOWER44' - 0"17' - 2"3' - 1"17' - 5"3' - 6"2' - 10"5' - 5"7' - 1"10' - 0"10' - 0"12' - 6"90' - 0"45' - 0"45' - 0"6' - 6"6' - 1"7' - 1"5' - 6"5' - 7"2' - 7"5' - 7"6' - 1"BATH6-0 X 10-0LAUND.6-10 X 6-0PWDR5-0 X 6-0BEDROOM 311-0 X 13-0BEDROOM 211-0 X 12-9MASTER BED12-0 X 16-8W.I.C.6-5 X 12-9MASTERBATH15-6 X 6-0KITCHEN15-0 X 12-0LIVING14-6 X 15-6DINING10-0 X 15-53-0 X 6-0 SHOWER17' - 2"3' - 1"20' - 11"2' - 10"5' - 5"7' - 1"10' - 0"10' - 0"12' - 6"6' - 6"6' - 1"7' - 1"5' - 6"5' - 7"2' - 7"5' - 7"6' - 1"72" x 60"SINGLE HUNG(8' -0") HEAD72" x 60"SINGLE HUNGEERO(6' -11") HEAD72" x 60"SINGLE HUNGEERO(6' -11") HEAD32" x 80"36" x 80"32" x 80"32" x 80"60" x 80"32" x 80"30" x 80"POCKET32" x 80"72" x 60"SINGLE HUNGEERO(6' -11") HEAD72" x 60"SINGLE HUNG(8' -0") HEAD32" x 80"60" x 80"42" X 72"SINGLE HUNGTEMPERED(7' -6") HEAD30" X 30"FIXEDTEMPERED(6' -11") HEAD72" x 60"SINGLE HUNG(8' -0") HEAD30" x 80"POCKET32" x 80"36" x 80"32" x 80"32" x 80"60" x 80"32" x 80"30" x 80"POCKET32" x 80"32" x 80"60" x 80"30" x 80"POCKET72" x 60"SINGLE HUNG(8' -0") HEAD72" x 60"SINGLE HUNGEERO(6' -11") HEAD72" x 60"SINGLE HUNGEERO(6' -11") HEAD72" x 60"SINGLE HUNGEERO(6' -11") HEAD72" x 60"SINGLE HUNG(8' -0") HEAD72" x 60"SINGLE HUNG(8' -0") HEAD30" X 30"FIXEDTEMPERED(6' -11") HEAD42" X 36"FIXED(10' -6") HEAD42" X 36"FIXED(10' -6") HEAD42" X 72"SINGLE HUNGTEMPERED(7' -6") HEAD1-HR FIRE PARTITION -TYPICAL BETWEEN DWELLING UNITSPANTRY30" x 80"PANTRY30" x 80"6' - 9"6' - 10"3' - 7"7' - 0"19' - 10"6' - 9"6' - 10"3' - 7"7' - 0"16R @ 7 1/8", 15T @ 10"16R @ 7 1/8", 15T @ 10"13' - 7"3' - 7"7' - 0"13' - 7"3' - 7"7' - 0"19' - 10"2' - 10"5' - 0"4' - 2"7' - 10"7' - 10"4' - 2"7' - 10"4' - 10"9' - 9"2' - 5"3' - 10"4' - 4"5' - 10"7' - 1"6' - 4 1/2"1' - 1"6' - 6 1/2"6' - 11"5' - 10"4' - 4"3' - 10"2' - 5"9' - 9"4' - 10"2X62X62X62X62X62X62X62X62X62X62X62X66R @ 7 5/8", 5T @ 10"18R @ 7 5/8", 17T @ 10"18R @ 7 5/8", 17T @ 10"6R @ 7 5/8", 5T @ 10"4' - 10"2' - 6"18' - 11 1/2"18' - 2"19' - 10"1' - 1"18' - 2"18' - 11 1/2"2' - 6"4' - 10"2X62X68-0 X 3-6 ISLAND8-0 X 3-6 ISLANDPROVIDE GAS TO RANGEPROVIDE GAS TO RANGEMIRRORS TO BE RECESSED MEDICINE CABINETSMIRRORS TO BE RECESSED MEDICINE CABINETSMIRROR TO BE RECESSED MEDICINE CABINETMIRROR TO BE RECESSED MEDICINE CABINETMIRRORS TO BE SURFACE MOUNTED MEDICINE CABINETSNOTE:ALL WINDOW OPENINGS WITH A SILL LESS THAN 36" TO THE FLOOR SHALL MEET THE REQUIREMENTS OF IBC 1015.8 AND 1015.8.1 FOR OPENING CONTROL DEVICESSECOND FLOOR/BALCONY SHALL BE SERVED WITH FORCED AIR HEATING/COOLINGSECOND FLOOR/BALCONY SHALL BE SERVED WITH FORCED AIR HEATING/COOLINGFLOOR LINE ABOVEFLOOR LINE ABOVEFLOOR LINE ABOVEFLOOR LINE ABOVEHANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. 34"-38" IN HEIGHT WITH A GRIPPING SURFACE PER R311.7.8.3.HANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. 34"-38" IN HEIGHT WITH A GRIPPING SURFACE PER R311.7.8.3.FLOOR AREASPER UNIT1ST FLOOR (COMMERCIAL): 1,980 SF GROSS2ND FLOOR (RESIDENTIAL): 1,908 SF GROSSTOTAL: 3,888 SF GROSSRESIDENTIAL AREA = 49.1% GROSS AREA OF BLDG.BALCONY: 338 SFROOF TERRACE: 740 SFPLAN NOTES1. CONTRACTOR TO CONFIRM SIZE & TYPE OF WATER HEATER, SET HEATER IN 1 1/2" DEEP 24 GA. GALVANIZED STEEL PAN DRAINED w/ 3/4" INDIRECT WASTE PIPE. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO PREVENT HORIZONTAL MOVEMENT2. ELEVATE WATER HEATER 18" MINIMUM ABOVE GARAGE SLAB TO ANY ELEMENT OR SWITCH THAT MAY SPARK3. A PERMANENT CRAWL SPACE LADDER OR ATTIC SPACE PULL DOWN LADDER IS TO BE INSTALLED TO ACCESS THE HEATING UNIT OR BOILER. 4. THE MAXIMUM CLEAR TRAVEL PATH FROM THE CRAWL SPACE OR ATTIC ACCESS OPENING TO THE HEATING UNIT OR BOILER IS 20 FEET.5. PROVIDE LIGHT FIXTURE CONTROLLED BY A SWITCH LOCATED AT THE CRAWL SPACE ACCESS HATCH & A RECEPTACLE OUTLET SHALL BE INSTALLED AT OR NEAR THE FURNACE.MECHANICALEGRESS WINDOWS (EERO)SAFETY GLAZING REQUIREMENTS1. TEMPER GLAZING AT LOCATIONS SPECIFED IN IRC 2018 R308.4 FIRE RESISTANT CONSTRUCTION REQUIREMENTS1. DOOR(S) BETWEEN GARAGE & HOUSE SHALL BE 20-MINUTE & EQUIPPED WITH A SELF-CLOSING DEVICE.2. INSTALL 1/2" GWB @ WALLS & UNDER-STAIR SURFACE IN ENCLOSED ACCESSIBLE SPACE UNDER STAIRS 3. 1/2" GWB SHALL BE INSTALLED ON ALL WALLS SEPARATING THE GARAGE FROM THE DWELLING .4. WHERE HABITABLE ROOMS ARE ABOVE A GARAGE, APPLY 5/8" TYPE 'X' GWB ON GARAGE CEILING & 1/2" GWB ON WALLS SUPPORTING FLOOR ABOVE5. FOAM INSULATION SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVEDTHERMAL BARRIER OF MINIMUM 1/2 INCH GWB OR A MATERIAL THAT IS TESTED IN ACCORDANCE NFPA 275.6. PROVIDE FIRE BLOCKING VERTICALLY AT THE CEILING AND FLOOR LEVELS & HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.7. PROTECTION OF PENETRATIONS IN WALLS OR FLOOR/CEILING ASSEMBLIES ARE REQUIRED TO BE FIRE RESISTANCE RATED IN ACCORDANCE WITH SECTION R302.2 OR R302.38. THE FLAME SPREAD FOR WALLS AND CEILINGSFINISHED TO BE NOT GREATER THAN 200. (R302.9.1)9. THE SMOKE-DEVELOPED INDEX FOR WALLS AND CEILINGS SHALL NOT HAVE AN INDEX GREATER THAN 450. (R302.9.2)ALL SLEEPING ROOMS SHALL HAVE ANEMERGENCY ESCAPE AND RESCUE OPENING (EERO), DIRECTLY TO THE OUTSIDE VIA A DOOR OR WINDOW. EGRESS WINDOWS SHALL MEET THE REQUIREMENTS OF IRC 2018 SECTION R310.1GENERAL NOTES1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT.2. GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL, ELECTRICAL, AND PLUMBING.APPLICABLE CODES:2018 INTERNATIONAL RESIDENTIAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODEDESIGN CRITERIASEISMIC ZONE D0115 MPH WINDENERGY REQUIREMENTS2018 INTERNATIONAL ENERGY CONSERVATION CODEMONTANA CLIMATE ZONE 6BINSULATION & FENESTRATION REQUIRMENTS BY COMPONENTCEILING FLAT: FLAT R-49VAULTED R-38WALLS: ABOVE GRADE R-21BASEMENTS R-19 CAVITY/ R-15 CONT.CRAWL SPACE R-19 CAVITY/ R-15 CONT.FLOORS: OVER UNHEATED SPACES R-30PERIMETER SLAB FOR 4 FT. R-10EXTERIOR DOORS R-3WINDOWS NFRC UNIT RATING U-0.30WATER HEATER ENERGY FACTOR RATING 0.58HEATING SYSTEM ENERGY EFFICIENCY RATING 78%(AFUE FOR GAS; HSPF HEAT PUMP)1-HR COMMON WALL1-HR COMMON WALL ASSEMBLY B/W DWELLING UNITSDESIGN NO. U341 (ANSI/UL 263), STC 51 (TEST NO: NGC 2191)• 5/8" SHEETROCK FIRECODE C CORE GYPSUM PANELS APPLIED VERTICALLY OR HORIZONTALLY TO EA. SIDE OF DOUBLE ROW OF 2X6 WOOD STUDS w/ 1-7/8" LONG 6d COATED NAILS, 7" O.C. - JOINTS STAGGERED ON OPPOSITE SIDES• (2) 2X6 WOOD STUD WALLS ON SEPARATE 2X6 PLATES (NO MIN. SPACING), 2X6 STUDS SPACED AT 16" O.C.• 7/16" WOOD STRUCTURAL PANELS MAY BE INSTALLED ON THE INSIDES OF EACH STUD WALL IF REQUIRED STRUCTURALLY• 3 1/2" (MIN.) BATT INSULATION INSTALLED IN 1 STUD WALL TO ACHIEVE STC RATING (51)(406) 552-4490www.blackmountainarch.comBLACK MOUNTAIN ARCHITECTURE 2020A2.22ND FLOORPLANSWISS PLAZA DUPLEXBUILDING 7 (3006 N. 27th AVE.)3006 N. 27th AVENUE, BOZEMAN, MONTANAPERMIT SETNOVEMBER 15, 2022200241/4" = 1'-0"12ND FLOOR PLANNOTE:EMERGENCY ESCAPE AND RESCUE OPENINGS REQUIRE THE FOLLOWING MINIMUM OPENING AREA PER SECTION 310.2.1 REQUIRING THAT NET OPENING HEIGHT NOT LESS THAN 5.7 SQ. FT., MINIMUM OPENING HEIGHT NOT LESS THAN 24", MINIMUM WIDTH NOT LESS THAN 20". THE CLEAR OPENING HEIGHT (SILL) FROM FINISHED FLOOR NOT MORE THAN 44".